Xbd - Z Type Horizontal Single Stage Electric-Drive Fire Pump

China Xbd

Model NO.
XBD fire pump
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Fire Pump
Industry
Fire Pump
Media
Fire Pump
Performance
Automatic Pump
Theory
Electromagnetic Pump
Drive Method
Electric-Drive Fire Pump
Pressure
0.8MPa
Flow
30 Liters Per Second
Caliber
100mm
Trademark
headita
Transport Package
Wooden Box
Specification
XBD8.0/30-100L
Origin
China
HS Code
8413709990
Model NO.
XBD fire pump
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Fire Pump
Industry
Fire Pump
Media
Fire Pump
Performance
Automatic Pump
Theory
Electromagnetic Pump
Drive Method
Electric-Drive Fire Pump
Pressure
0.8MPa
Flow
30 Liters Per Second
Caliber
100mm
Trademark
headita
Transport Package
Wooden Box
Specification
XBD8.0/30-100L
Origin
China
HS Code
8413709990
Product overview
The self-priming pump set and non-clogged sewage into an organic whole, the axial back mixing type, and through the unique design of the pump body, impeller flow channel can be like general self-priming centrifugal pump.

Xbd - Z Type Horizontal Single Stage Electric-Drive Fire Pump


Not only do not need to install the bottom valve and irrigation water diversion, but also  inhale row containing large granular solid and liquid long fiber impurities.


Product features
XBD self-priming fire pump is according to the regulation of our country fire regulations and all kinds of different requirements of users, on its own research and development of electromechanical integration equipment.
1,Product innovativeadvancedpracticalsimplify the design of pump room between can change between underground pump house to the ground, convenient construction, save the investment
2,Can use outdoor pool also meet the use requirements
3,Use of self-priming function can do fire pool depth to 6 m, so that under the same volume, the pool of the occupation of land area is much smaller than the original, saving land, convenient construction, lower cost, also can greatly save the investment
4,Can work under the condition of negative level, timely meet the requirements of the fire
5,Self-priming fire pump water timely, timely relief fire
6,Have close and reliable automatic circuit detection function, make the unit under standard fire at ordinary times, once need to be able to get instant water supply, into the fire

Xbd - Z Type Horizontal Single Stage Electric-Drive Fire Pump



Main purpose
Can be widely used in municipal drainage project, studied the breeding, light industry, papermaking, textile, food, chemical, electric power, chemical media such as fiber, paste and mixed suspension is the most ideal impurity pump.


Model Table
 
ModelCapacityHeadRotation
Speed
FrequencyPowerEfficiencyImpeller 
Dia.
Diameter
ShaftInletOutlet
m3/hL/smr/minhzkw%mmmmmm
DA50/2018.0 5.00 15.31450501.27 592146550
30.0 8.33 13.31.67 65
36.0 10.00 11.81.86 62
36.0 10.00 62.029005010.48 58
60.0 16.67 56.013.07 70
72.0 20.00 51.014.70 68
18.0 6.03 22.31750601.85 59
30.0 10.05 19.42.43 65
36.0 12.06 17.22.72 62
43.5 12.07 90.335006018.42 58
72.4 20.12 81.622.98 70
86.9 24.14 74.325.85 68
DA50/20A17.2 4.79 14.01450501.15 57.52056550
28.7 7.98 12.01.45 64.5
34.5 9.58 10.61.63 61
34.5 9.58 56.32900508.81 60
57.5 15.97 50.311.53 68.3
69.0 19.16 44.712.82 65.5
17.2 5.78 20.51750601.67 57.5
28.7 9.63 17.52.12 64.5
34.5 11.56 15.42.38 61
41.6 11.56 82.035006015.49 60
69.4 19.27 73.320.26 68.3
83.3 23.13 65.122.53 65.5
DA50/20B16.4 4.55 12.51450501.02 54.51956550
27.3 7.59 10.71.26 63
32.8 9.11 9.41.40 60
32.8 9.11 51.32900507.77 59
54.7 15.19 44.710.01 66.5
65.6 18.23 40.011.16 64
16.4 5.50 18.21750601.49 54.5
27.3 9.16 15.61.84 63
32.8 10.99 13.72.04 60
39.6 11.00 74.735006013.65 59
66.0 18.33 65.117.59 66.5
79.2 22.00 58.319.63 64
DA50/20C15.6 4.32 11.11450500.90 521856550
25.9 7.20 9.61.11 61.5
31.1 8.64 8.21.19 58.5
31.1 8.65 46.22900506.75 58
51.9 14.41 40.28.67 65.5
62.3 17.29 35.49.68 62
15.6 5.21 16.21750601.32 52
25.9 8.69 14.01.61 61.5
31.1 10.43 11.91.73 58.5
37.6 10.44 67.335006011.86 58
62.6 17.39 58.615.25 65.5
75.1 20.87 51.617.01 62
DA50/20D14.7 4.09 9.81450500.76 51.51756550
24.5 6.81 8.30.95 58.5
29.4 8.17 7.21.05 55
29.4 8.18 41.32900505.86 56.5
49.1 13.63 36.27.56 64
58.9 16.36 31.48.60 58.5
14.7 4.93 14.31750601.11 51.5
24.5 8.22 12.11.38 58.5
29.4 9.87 10.51.53 55
35.5 9.87 60.235006010.30 56.5
59.2 16.45 52.713.28 64
71.1 19.74 45.715.13 58.5
DA50/20E13.9 3.85 8.61450500.66 491656550
23.1 6.42 7.10.81 55
27.7 7.71 5.90.86 52
27.8 7.71 36.72900505.14 54
46.3 12.85 32.26.76 60
55.5 15.42 27.57.42 56
13.9 4.65 12.51750600.97 49
23.1 7.75 10.31.18 55
27.7 9.30 8.61.25 52
33.5 9.31 53.53500609.04 54
55.8 15.51 46.911.88 60
67.0 18.61 40.113.05 56



The Service
1.Delivery: Delivery time will be on time as the contact. Usually, the delivery time is of centrifugal pump is for 15-25 working days.
2.Warranty: 1 year for the pump body, 3 months for the main working parts.
3.Package:According to your quantity, we use plywood case which is durable for ocean transport.
4.Shipping: By Sea and By Air
5.Payment: We are accept T/T,L/C,West Union and so on.
6.Pre-sales Service:According to your requirement, we will give your our profession advice of pump solution. 
7.On-sales Service:We will clearly show you everything in fact when you place an order with us. We will takes photos or videos to show you order production situation.
8.After-sales Service: We will full report you the production progress and plan. Meanwhile, we will follow up the pump working conditions per three months when the pumps put into use, and can send the spare parts to you within one week if you need. 



Structure and Working principle

XBD - Z series self-priming fire pump, mainly composed of pump body, impeller, back cover, pump shaft, bearing, mechanical seal tube inlet valve, gas/liquid separation, water valves, into, row of nozzles.The structure of the pump is shown in figure
The working principle of pump: the pump body is equipped with liquid storage chamber, and through the cycle of the drain holes and the above hole and pump working chamber are interlinked, constitute the axial flow pump outer recirculation system.Pump stop working after pump inner cavity has a certain volume of liquid storage.When the pump starts, under the action of reservoir in the pump impeller, the air entrainment was thrown up, liquid through the grid work back into the cavity of the gas-liquid separation pipe, make the pump in a certain degree of vacuum, achieve the effect of imbibition.



Installation requirements

1, before installation shall carefully check the pump body abortion in presence of rigid objects, to avoid damage to the impeller and the pump body when running.
2, install piping quantity are not allowed to add on the pump, lest make pump deformation, affect the normal operation.
3, tighten the anchor bolts, lest start when the vibration impact on pump performance.
4, on the road at the inlet and outlet pipe of pump installation regulator, installed near the pump outlet pressure gauge, to control the operation of the pump in rated conditions, to ensure the normal use of the pump.
5, discharge line such as non-return valve should be installed outside the gate.
6, pump installed installation is divided into rigid connection and flexible connection.


All My Striving,For Your Satisfaction.
***********************************************************************************************************************
Contact Miss Karine (Mobile :+86 13672811846
 )   
 
 
 
WebSite:headita.en.made-in-china.com