China 110V Input Voltage and 100-150W Output Power 5V6a/24V4a Dual Power Supply D-120b, Find details about China Switched-Mode Power Supply, SMPS from 110V Input Voltage and 100-150W Output Power 5V6a/24V4a Dual Power Supply D-120b
MODEL | D-120A | D-120B | |||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH1 | CH2 |
DC VOLTAGE | 5V | 12V | 5V | 24V | |
RATED CURRENT | 12A | 5A | 6A | 4A | |
CURRENT RANGE | 2 ~ 12A | 0.5 ~ 5A | 2 ~ 10A | 0.4 ~ 4A | |
RATED POWER | 120W | 126W | |||
RIPPLE & NOISE (max.) Note.2 | 60mVp-p 120mVp-p | 60mVp-p 150mVp-p | |||
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | ||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±2.0% | ±7.0% | |
LINE REGULATION | 0.50% | 1.00% | ±0.5% | ±1.0% | |
LOAD REGULATION | ±0.5% | ±5.0% | ±0.5% | ±6.0% | |
SETUP, RISE, HOLD TIME | 200ms, 50ms, 20ms at full load | ||||
INPUT | VOLTAGE RANGE | 88 ~ 132VAC/176 ~ 264VAC selected by switch 248 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~63Hz | ||||
EFFICIENCY (Typ.) | 78% | 80% | |||
AC CURRENT | 2.8A/115VAC 1.6A/230VAC | ||||
INRUSH CURRENT (max.) | COLD START 35A | ||||
LEAKAGE CURRENT | <3.5mA/240VAC | ||||
PROTECTION | OVER LOAD | 105 ~ 135% rated output power | |||
Protection type : Shut down o/p voltage, re-power on to recover | |||||
OVER VOLTAGE | CH1:5.75 ~ 6.75VDC | ||||
Protection type : Shut down o/p voltage, re-power on to recover | |||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60°C (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -20 ~ +85"C, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) on +5V output | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY & | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 Approved | |||
EMC | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
(Note 4) | ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A | ||||
OTHERS | MTBF | 272.8K hrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 199*110*50mm (L*W*H) | ||||
PACKING | 0.85Kg; 24pcs/14.2Kg/0.95CUFT | ||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |||||
NOTE |