Air Cooled Water Chiller with Heat Recovery

China Air Cooled Water Chiller with Heat Recovery, Find details about China Chiller, Air Cooled Water Chiller from Air Cooled Water Chiller with Heat Recovery

Certification
ISO, CE, CCC
Condition
New
Usage
Heating/Cooling + Hot Water
Trademark
Tili
Origin
Guangdong Province
HS Code
8418619000
Certification
ISO, CE, CCC
Condition
New
Usage
Heating/Cooling + Hot Water
Trademark
Tili
Origin
Guangdong Province
HS Code
8418619000
1) Saving energy:COP up to 8.32
2) Operating range : -10 to 48 degree
3) Noise level low to 54dB(A)
4) Smart control based on module combination
5) High efficiency H.E.
6) Air Cooled absorption chiller with Heat Recovery

Air Cooled Water Chiller with Heat Recovery

i) Installation:

Air Cooled Water Chiller with Heat Recovery


ii) Inner system:
Air Cooled Water Chiller with Heat Recovery
Model No.
EKAC230BRSREKAC460BRSREKAC690BRSREKAC920BRSREKAC1150BRSREKAC1380BRSR
Air conditioning modeNominal cooling capacitykw65.5131196.5262327.5393
Nominal heating capacitykw69138207276345414
 Nominal cooling input powerkw19.438.858.277.697116.4
 Nominal heating input powerkw19.238.557.776.996.2115.4
Water flow rate for nominal cooling capacitym3/h11.322.533.845.156.367.6
Water flow rate for nominal heating capacitym3/h11.923.735.647.559.371.2
Hot water modeNominal water supply capacitykw16.332.74965.481.798
Nominal heating capacitykw76152228304380456
Total power of nominal heating capacitykw18.436.755.173.591.8110.2
Cooling + heat recovery modeNominal cooling capacitykw59.7119.4179.1238.8298.5358.2
Nominal heat recovery capacitykw76152228304380456
Nominal input powerkw16.332.648.965.281.597.8
Nominal water supply capacity at heat recovery sidem3/h16.332.648.965.281.597.8
Nominal water flow at
evaporator side
m3/h10.320.530.841.151.361.6
Power supplyv/ph/hz380/3/50
Flow control
Electronic expansion valve
Refrigerant
R22
Heat  exchanger typeAir conditioning sidem³/hbraze-welded panel-type heat exchanger
hot water sidem³/hHigh-efficiency bucket heat exchanger
CompressorQtySet24681012
FanQtySet24681012
Water
resistance
Air conditioning sidekPa454545454545
hot water sidekPa757575757575
Minimum
diameter for
water pipes
Air conditioning sideinch≥2≥3≥3≥4≥4≥5
hot water sideinch≥2≥3≥4≥4≥5≥5
DimensionsL×Hmm 2012×1840
Widthmm 88021253370461558607105
Power cable specificationSection area of live linemm²≥10≥35≥70≥95≥120≥150
Qty.of live lines
3
Section area of null linemm²≥4
Qty.of live lines
1
Section area of grounding linemm²≥10≥16≥35≥50≥60≥75
Qty.of grounding lines
1
Net weightkg60012001800240030003600
Operation weightkg62012401860248031003720
Note:
1. Air conditioning mode: Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172 m3/(h@kW); outdoor ambient temperature
35°C. Test conditions for nominal heating capacity: outlet water temperature: 45°C; water flow: 0.172 m3/(h@kW); temperature of outdoor dry/wet bulb: 7°C/6°C.
2. Cooling + Heat recovery mode Test conditions for nominal cooling capacity: Hot water side: temperature of outlet water 45°C, water flow 0.215 m3/(h@kW); Air
conditioning side: temperature of outlet water 7°C, water flow 0.172 m3/(h@kW);
3. Hot water mode: Test conditions for nominal water flow: Ambient temp: 20/15°C; outlet water temp: 45°C; water flow of cooling + heat recovery mode.
4. Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter.
5. Water resistance at the hot water side includes water pressure drop of the unit and does not include the pressure drop at the Y-shaped filter and other
components.
6. Pipes outside the unit need to be customized and installed on site. The diameter of the pipes must meet design requirements. TILI does not provide the pipes.
7. Full heat recovery units and other units can be combined to form partial heat recovery modular system. Full heat recovery units can also be combined to form a
total heat recovery system. Modular units can be formed using the 1~16 basic modules. The above table lists the parameters for common module combinations.
8. For on-site electric wiring, see the name plate or installation menu of the unit.