China Overhead Crane Load Pin Overload Limit Device Lifting Weight Control Limiter, Find details about China Crane Load Lifting Limiter, Crane Load Limiter from Overhead Crane Load Pin Overload Limit Device Lifting Weight Control Limiter
The lifting load control limiter CRN-GX+OMS-370C is one kind of split overload limiter, and it consist of load lin CRN-GX and the overload weight controller OMS-37C,and it is more flexible. Load cell pins are particularly useful for use in applications, where pulleys are being used to lift a load. The load cell pin CRN-GX is suitable for numerous applications on lifting motors and handling equipment. The load pins CRN-GX can be used to measure forces on rotating components (pulleys, sheaves, etc.) and can be directly mounted on shackles,and it is available to provide the tailor-made load pin at your requests.
Parameters of load pin limiter CRN-GX-OMS-370C:Pin load cell : CRN-GX | |||
Rated load | 3T/5T/5T/10T | Ultimate overload | 200% F.S |
Repeatability | ±0.5%F.S | Total error | ±0.5%F.S |
Sensitivity | 2.0±0.02%mV/V | Material | Alloy Steel |
Excitation voltage | ≤15VDC | TC SPAN | ±0.02%F.S/10ºC |
Input impeance | 760±10Ω | Product Creep | ±0.05% F.S./30mins |
Output impedance | 700±2Ω | Cable Length | 5m |
Insulation impedance | ≥5000MΩ | Working temperature | -30ºC~+70ºC |
Safe overload ratio | 150%F.S | Protection class | IP67/IP68 |
Overload controller: | OMS-370C | ||
Operation Voltage: | AC/DC16-48V | Key number | 6 |
Nominal power: | ≤4W | Measuring precision: | 0.1% |
Load cell channel: | 1 | Operation temperature: | -45degree-+85degree |
Relay Number: | 1(overload,NO/NC) | Sensor operation voltage: | DC15V |
Contact Load: | 5A 250VAC/5A 30VDC | External screen | External big screen (optional) |
Display Type: | 4 digits 0.36 inch LED display | Connection terminals type for load cell | Compatible with 4-core bank wire |
Display mode: | Weight/percentage | Weight: | 265g |
Key numbe:r | 6 |