First Aid Aed Equipment/Public Use Automatic External Defibrillator

China First Aid Aed Equipment/Public Use Automatic External Defibrillator, Find details about China Defibrillator, First Aid Equipment from First Aid Aed Equipment/Public Use Automatic External Defibrillator

Model NO.
AED7000F
Anesthesia
Non
Type of Operating Light
Non
Output
Biphasic Truncated Exponential
Energy Sequence
150, 150, 200j
Charge Time
8 Sec. to 150j; 10 Sec. to 200j (New Battery)
Analysis Time
9 Sec.
Audible Prompts
22 Audible Prompts
Visual Prompts
LED Prompts
Controls
Two Buttons-on/off, Shochk
The Maximum Voltage
1200±50V
Non-Rechargeable
12V DC, 2.8ah
Battery Capacity
at 150 Joules
Trademark
MSL
Transport Package
Standard Export Packing
Specification
303*216*89mm
Origin
Guangdong, China
HS Code
9018909000
Model NO.
AED7000F
Anesthesia
Non
Type of Operating Light
Non
Output
Biphasic Truncated Exponential
Energy Sequence
150, 150, 200j
Charge Time
8 Sec. to 150j; 10 Sec. to 200j (New Battery)
Analysis Time
9 Sec.
Audible Prompts
22 Audible Prompts
Visual Prompts
LED Prompts
Controls
Two Buttons-on/off, Shochk
The Maximum Voltage
1200±50V
Non-Rechargeable
12V DC, 2.8ah
Battery Capacity
at 150 Joules
Trademark
MSL
Transport Package
Standard Export Packing
Specification
303*216*89mm
Origin
Guangdong, China
HS Code
9018909000
2016 New hot first aid AED equipment automatic external defibrillator for public use (AED7000F)

 Features of the automatic external defibrillator:
1. AED
2. Two-button operation, lock-out protection
3. Biphasic energy output
4. External voice and visual prompt
5. CE, ISO13485

Product Description:
This automactic external defibrillator is a portable model, which can be equipped at home, in public places, or in the hospitals. It is very easy and convienient to use when give first-aid to patient. It has voice prompts and sophisticated self-testing software, even thought you are a untrained user, you can also use it for first aid.
Meanwhile, it has the function of automatic analyzing patient's ECG data, and then takes corresponding defibrillator energy level according to patient's curent situation, which has greatly improved success rate, and maximum reduced damage to patient's heart.

Overview of the automatic external defibrillator:
1. Three-step defibrillation process
2. Two-button operation
3. Extensive voice and visual prompts for the operator
4. Biphasic energy output
5. Lock-out protection to prevent inadvertent defibrillation
6. Continuous event recording for reporting each use to printer or computer
7. Weekly self-test to ensure readiness

Detail specification of the  automatic external defibrillator:

OutputBiphasic Truncated Exponential
Energy Sequence150, 150, 200J
Chare time8 sec. to 150J; 10 sec. to 200J (New battery)
Analysis time9 sec.
The maximum time from the initiation of rhythm analysis to readiness for discharge with a new batteryLess than 30 seconds
The maximum time from the initiation of rhythm analysis to readiness for discharge after 6 shocksLess than 35 seconds
The maximum time from initially switching power on to readiness for dischargeLess than 25 seconds
Audible prompts22 audible prompts
Visual promptsLED prompts
Controls Two buttons-ON/OFF, shock
Output Energy Accuracy±15% into any impedance from 25 to 175Ω
The Maximum Voltage1200±50V
Output disabled when the patient impedance is outside limits20Ω TO 200Ω

Battery of the defibrillator:
Part No.CR123A-4*2
Non-rechargeable12V DC, 2.8Ah
CapacityAt 150 Joules

Physical of the defibrillator:
Dimensions303*216*89mm
Weight2.0kg
Operating Temperature0°C to 40°C
Operating HumidityRelative humidity between 30% and 95% (non-condensing)
Storage Temperature (without battery)-20°C to 55°C
Storage Humidity (without battery)Up to 95% (non-condensing)


 