China Tings Automatic UF Water Filter / Ultrafiltration Water Treatment System, Find details about China UF Water Plant, UF Treatment Plant from Tings Automatic UF Water Filter / Ultrafiltration Water Treatment System
UF membrane
The molecular weight range of UF ultrafiltration membrane is 1000-200000 Dalton. The ultrafiltration membrane can intercept the impurities
(such as protein, pigment and polysaccharide) through the target products.It can retain the target product, through small molecular impurities
(inorganic salt, small molecular pigment, monosaccharide, ash, etc.) and water, can also separate the target product of different molecular
weight, so as to replace the traditional activated carbon decolorization, resin impurity removal, crystallization extraction and other purification
process, achieve the purpose of decolorization, impurity removal and product classification.UF ultrafiltration membrane, UF ultrafiltration
membrane has become a high and new technology of concentration and separation, and is most widely used in the water treatment industry
UF system technology introduction
UF ultrafiltration membrane has become a high and new technology of concentration and separation, which is most widely used in water
treatment industry.It is to use the pressure difference to promote the membrane separation process, the solution in the raw material through the
high pressure through the membrane element, at this time to achieve the purpose of concentration and separation and solution purification.The
whole process of the equipment will not cause any pollution, so it is favored by all walks of life.
UF system running features
1. The filter membrane will not undergo phase change during operation, and can be operated at room temperature or low pressure, thus its operation energy consumption is low;
2. The membrane element will not change any substance in the process of concentration and separation and will not cause secondary pollution;
3. Substances with different molecular weights can be separated in different grades;
4. No impurities will fall off during the operation of the ultrafiltration membrane to ensure the purity of the ultrafiltrate;
5. The ultrafiltration membrane is characterized by selective separation and can retain mineral elements beneficial to human body;
UF system application domain editing
1. Electronic industry: semiconductor industry ultra-pure water equipment, integrated circuit cleaning water treatment equipment;
2. Pharmaceutical industry: medical pure water, drug concentration and separation;
3. Water treatment project: preparation of purified water, purification of drinking water, reverse osmosis device;
4. Food industry: concentrate and clarify juice, concentrate and separate protein;
5. Wastewater treatment engineering: industrial wastewater, municipal wastewater treatment and reuse, etc.;
These industries are widely used in the application of ultrafiltration membrane industry, there are many enterprises in the production process
using ultrafiltration membrane technology.
Items | Permissible Value | Probably Consequence of Excessive Standard | Improvement Suggestions | |
Suspended solids | Tubidity | <1NTU | Sludge ,colloid pollution | Flocculation and filtration |
SDI15 | <5 | |||
Metal oxides | Fe ( mg/L) | <0.05 | Iron Pollution | Oxidation precipitation/filtration |
Mn (mg/L) | <0.05 | |||
Scale forming matter | CaCO3 | LSI<0 | Concentrated water side does not permit scaling | Decrease recovery rate , PH value , or add scale inhibitor |
Other insoluble salt | / | |||
Organics | Oil | 0 | Organics and oil | Air |
TOC (mg/L) | <10 | Organics pollution | Activated carbon adsorption , filtration | |
CODcr (mg/L) | <10 | |||
BOD5 (mg/L) | <5 | |||
Si (mg/L) | <20 | Colloid pollution | ||
PH | 3-10 | Too low or too high PH will accelerate the aging speed of membrane | Regulation of Acid-base | |
Temperature | 5-45°C | Low temperature will easily produce scaling of undissolved salt High temperature will accelerate the aging speed of membrane | Heat exhanger | |
Oxidizer | Residual chlorine (mg/L) | <0.1 | Membrane system will be oxidized | Reductant or aclivated carbon adsorption |
Ozone and others | 0 |