Medical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen Breathing

China Medical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen Breathing, Find details about China Oxygen Regulator, Medical Oxygen Regulator from Medical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen Breathing

Origin
China
HS Code
8515900000
Origin
China
HS Code
8515900000
Medical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen Breathing

Medical oxygen is for oxygen breathing in hospital or home and meant to be connected on high pressure medical gas cylinder to decrease the outlet pressure and supply a stable low pressure for use.
The pressure gauge indicates the pressure level of the gas cylinder.

 

Specification: 

1.The oxygen inhaler (buoy type) is mainly used in the medical center oxygen supply system for the first-aid oxygen supply and oxygen-deficient patients in the medical unit for oxygen inhalation, scientific research institutions, industrial and mining, etc.
2.The oxygen inhaler has precise flow and is easy to use and safe. It is an indispensable device for oxygen therapy in emergency rooms and wards of hospitals.
3.The medical pressure reducer is designed to reduce the pain of users.
4.The product has accurate output, stable quality, high quality and safe performance, which will make you safer, more assured and more satisfied during use.

Features:* Aluminum body with brass core
* 3000psi maximum inlet pressure
* 1-1/2'' diameter UL-listed gauge
* Complies to CGA standard
* Internal relief valve
* Piston design regulator
* Sintered bronze inlet filter for longer service life
* Easy to read flow rate window
* Alternative color(green, blue, yellow)
* Selection of 0-4 0-8 0-15 0-25 each with 12 flow settings
* ISO13485 certification
 Application Medical oxygen regulator is used for oxygen breathing in hospital or home and meant to be connected on high pressure medical gas
cylinder to decrease the outlet pressure and supply a stable low pressure for use.
The pressure gauge indicates the pressure level of the gas cylinder.
Safety valve: 0.5Mpa automatic exhaust
Inlet Connection: G5/8''
Outlet Connection: M12x1
Equipped with humidification bottle

Medical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen BreathingMedical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen BreathingMedical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen BreathingMedical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen BreathingMedical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen BreathingMedical Oxygen Regulator Oxygen Flowmeter for Medical Oxygen Breathing
Intended Use:
It is mainly used in the oxygen supply system of the medical center, which is used by medical units for emergency oxygen and hypoxic patients for oxygen inhalation, scientific research institutions, industrial and mining and other inhalation flow control devices. The flow rate of the oxygen regulator is accurate, convenient and safe to use. It is an essential device for oxygen therapy for patients in hospital emergency rooms and wards.

Working Principle:
The role of the oxygen regulator is to provide a continuous constant pressure and flow of oxygen for patients to use. The bottle plug-in oxygen regulator uses its own pressure reducing device to reduce the high pressure in the oxygen cylinder (15Mpa pressure when the bottle is full) to a low pressure suitable for human use (0.2~0.2Mpa), and then output to the human body after being moistened by water. Since the wall plug-in oxygen regulator has an input pressure of 0.2~0.4Mpa, it does not need to be decompressed and can be directly output to the human body.
Operation method:
1. Add distilled water to the humidification cup. The water level in the bottle cannot be higher than the upper water line, but not lower than the lower water line. It is forbidden to use normal saline instead.
2. Before inserting the regulator into the oxygen supply terminal socket, you should turn off the flow adjustment switch and adjust the direction of the oxygen quick plug, and then insert the quick plug into the oxygen supply terminal socket. When you hear a "click" sound and see the oxygen supply terminal When the locking sleeve of the socket slides automatically, it indicates that the quick plug and the oxygen supply terminal socket have been connected and locked.
3. Before supplying oxygen, insert the oxygen inhalation tube into the oxygen supply connector, and then turn the flow adjustment switch counterclockwise to turn on the origin, so that the float rises slowly (the scale line aligned with the center of the float is the flow reading, and the unit is liters/min) , The oxygen supply can be adjusted according to needs.
4. During the oxygen supply process of the regulator, if the water in the regulator bottle is lower than the lower water line, the flow adjustment switch should be closed in time, the humidification bottle should be unscrewed, and distilled water should be added according to the requirements of Article 1 of this item. Screw on the body of the regulator and continue oxygen supply.
5. When the regulator is not in use, the air source of the regulator should be turned off; if you need to remove it, hold the regulator with your hand and remove it after proceeding (the engineering installation unit is responsible for the explanation of the unlocking method of the different oxygen supply terminal sockets), and then after the water in the bottle is cleaned and disinfected, it is stored in a non-corrosive and well-ventilated room.

Attention:
1.Make sure there is no ash on the connector and check the screw thread, then install the inhalator.
2.Make sure the flow meter is vertical to the floor and flow regulating valve is closed, then open the valve of oxygen cylinder slowly, regulate the flow after the high pressure gauge shows the pressure of the oxygen cylinder.
3.No drastic shock, far away with the corrosive substance, and no oil stain.
4.The set screw of the safety valve can't be rotated at random, non-professional people are forbidden to dismount.