LV PVC Power Cable Without Armoring

China LV PVC Power Cable Without Armoring, Find details about China Coaxial Cable, HDMI Cable from LV PVC Power Cable Without Armoring

Model NO.
PVC power cable
Conductor
Concentric Stranded Annealed Copper
Insulation
PVC (Polyvinyl Chloride)
Inner Sheath
PVC (Polyvinyl Chloride)
Sheath
Flame Retardant PVC (Polyvinyl Chloride)
Trademark
Eternal
Transport Package
Standard Export Package, Wooden/Steel Reel
Specification
VV, VLV, VV22, VLV22, VV32, VLV32
Origin
China
HS Code
8544601200
Model NO.
PVC power cable
Conductor
Concentric Stranded Annealed Copper
Insulation
PVC (Polyvinyl Chloride)
Inner Sheath
PVC (Polyvinyl Chloride)
Sheath
Flame Retardant PVC (Polyvinyl Chloride)
Trademark
Eternal
Transport Package
Standard Export Package, Wooden/Steel Reel
Specification
VV, VLV, VV22, VLV22, VV32, VLV32
Origin
China
HS Code
8544601200
Product Description

LV PVC Power Cable without Armoring

LV PVC Power Cable Without Armoring
LV PVC Power Cable Without Armoring

Rated voltage: 0.6/1KV, 1.8/3KV
Manufacturing standards: 
ASTM ICEA BS DIN IEC GB AS/NZS etc.
Operating features:
Operating temperature: Max. Permissible continuous operating temperature of Conductors shall not exceed 70ºC 
Conductor Short circuit temperature: Not exceeding 160ºC .( Max. duration 5 seconds)
Bending radius:
Bending radius of single core cable: 20D
Bending radius multi-core cable: 15D
D=Actual overall diameter of cable (mm)
Installation temperature:
The lowest temperature of installation is 0ºC . 
Laying conditions and basic parameters for calculating current ratings:
Method of laying  Ambient temperature
In air                              40ºC
Direct burial                   25ºC
Soil thermal resistivity 1.0ºC·m/W
Layout of single core cables: In triangle (Touch each other)
Sketches of product construction:
LV PVC Power Cable Without Armoring
1.Conductor 
2.PVC Insulation 
3.Filler 
4.Inner Cover 
5.Armour 
6.Outer sheath
Scope of cables
No .of
cores
Nominal area of condutor (mm2)
V V ,VLVV V 22,VLV 22V V32, VLV32
1*1.5-40010-30010-300
21.5-2404-30025-185
31.5-2404-3004-240
3+14-2404-30025-185
44-2404-24025-185
3+24-3004-300 
4+14-2404-240 
54-954-95 
* Non-magnetic matrials shall be applied for the armor of single core cable.

Type,description and main applications Table 1
TypeDescriptionMain application
VV
VLV
Cu or Al conductor PVC insulated PVC sheathed power cable For laying indoor and outdoor, unable to bear extermal mechanical force but the tractive force during laying. 
Laying Single core cable in magnetic duct is not permissible. 
V V 22
VLV22
Cu or Al conductor insulated steel tape armoured PVC sheathed power cable For laying underground, able to bear external mechanical force, but unable to bear large pulling force. 
V V32
VLV32
Cu or Al conductor XLPEinsulated fine steel wire armoured PVC sheathed power cable For laying underground, vertical well, or underwater, able to bear certain pulling force. 
Note: ZR is added in the front of the type of common power cable to form flame resistant power cable type. e.g. ZR-VV,ZR-VLV22,ZR-VV32 and so on.
Product Parameters
Single- core PVC Insulated PVC Sheathed Power Cable
AC 
Rated
 Voltage
Nom.
 Cross-section
mm2
Nom. 
insulation 
thickness 
mm
Nom. 
sheath 
thickness
 mm
Approx
OD of 
cable
 mm
Apporx 
weight
 of cable 
kg/km
Max.DC 
Resistance
 of Conductor
 at 20 ºCΩ/km
Current Rating  (A)
Direct in 
ground
Run in air
VVVLVCuAlCuAlCuAl
0.6/1kv1.50.81.46514212.1-----
2.50.81.4764497.4112.136272519
41.01.4890654.617.4147353326
61.01.48113763.084.6158464134
101.01.49158981.833.0878585744
161.01.4102211251.150.91100767659
251.21.4123211710.7271.20130989876
351.21.4134202100.5240.86815511511590
501.41.4155792790.3870.641185140145110
701.41.5177783580.2680.443225170180140
951.61.51910324620.1930.320270205225175
1201.61.62012765560.1530.253310235260200
1501.81.72215856840.1240.206350265300230
1852.01.72419338220.09910.164395300345270
2402.21.827247710360.07540.125455350410320
3002.41.930307412730.06010.100515395475370

Two- core PVC Insulated PVC Sheathed Power Cable
AC 
Rated
Voltage
Nom. 
Cross-
section
mm2
Nom.
insulation
thickness
 mm
Steel
tape
thickness
mm
Nom. sheath   thickness     mmApprox 
OD of 
cable
 mm
Apporx weight
 of cable 
kg/km
Max.DC 
Resistance
 of Conductor 
at 20 ºCΩ/km
Current Rating  (A)
Direct in
 ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv1.5 0.8 0.2 1.8 -11 -124 105 --12.1 20.16 26 -17 -
2.5 0.8 0.2 1.8 -12 -151 120 --7.41 12.1 34 26 23 18 
1.0 0.2 1.8 1.8 14 16 213 164 361 312 4.61 7.41 44 35 31 24 
1.0 0.2 1.8 1.8 15 17 271 197 430 356 3.08 4.61 556 45 38 32 
10 1.0 0.2 1.8 1.8 17 19 364 244 548 428 1.83 3.08 76 59 53 42 
16 1.0 0.2 1.8 1.8 19 21 494 302 702 509 1.15 1.91 100 77 71 55 
25 1.2 0.2 1.8 1.8 22 24 702 402 946 646 0.727 1.20 125 100 90 70 
35 1.2 0.2 1.8 1.8 24 25 902 482 1170 749 0.524 0.868 155 120 110 86 
50 1.4 0.2 1.8 1.8 23 26 1182 580 1418 829 0.387 0.641 185 145 135 105 
70 1.4 0.2 1.9 1.9 25 28 15779 737 1849 1016 0.268 0.443 230 175 165 130 
95 1.6 0.5 2.0 2.1 29 33 2111 969 2478 1606 0.193 0.320 275 210 210 165 
120 1.6 0.5 2.1 2.2 31 35 2598 1156 3218 1839 0.153 0.253 310 245 245 190 
150 1.8 0.5 2.2 2.3 34 38 3232 1429 3958 2172 0.124 0.206 350 275 280 215 
185 2.0 0.5 2.4 2.4 38 42 3974 1749 4787 2562 0.0991 0.164 395 310 320 250 
240 2.2 0.5 2.6 2.6 42 46 5092 2206 5948 3093 0.0754 0.125 455 350 375 295 


Three-core PVC Insulated PVC Sheathed Power Cable
AC 
Rated 
Voltage
Nom.
 Cross
section
mm2
Nom.
 insulation 
thickness 
mm
Steel
tape
thickness
mm
Nom. sheath
thickness     mm
Approx OD
 of cable
 mm
Apporx weight 
of cable 
kg/km
 Max.DC
Resistance
 of Conductor
at 20 ºCΩ/km
Current Rating  (A)
Direct in
 ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv1.50.8-1.8-11-147119--12.118.922-15-
2.50.8-1.8-12-186139--7.4112.129231915
41.00.21.81.814172611874173434.617.4138302620
61.00.21.81.815183322205003893.084.6147393226
101.00.21.81.818204642836584781.833.0865504635
161.00.21.81.820226583698785891.151.9184656047
251.20.21.81.8232695850812187670.7271.20110847760
351.20.21.81.82528125362115389060.5240.8681301009574
501.40.21.81.926281718817199111080.3870.64115512011590
701.40.21.92.0283222981036289416450.2680.443195150145115
951.60.52.12.2323631011388280820950.1930.320230185185140
1201.60.52.22.3353938221658458524200.1530.253260205210165
1501.80.52.42.4394347622057554828710.1240.206300230245190
1852.00.52.52.6434758362500676434290.09910.164335260280215
2402.20.52.72.7485274893162843841550.07540.125390300335260

(3+1)-core PVC Insulated PVC Sheathed Power Cable
AC
 Rated
 Voltage
Nom. Cross
section
mm2
Nom. 
insulation 
thickness 
mm
Steel
tape
thickness
mm
Nom. sheath
 thickness    mm
Approx
 OD of 
cable
mm
Apporx 
weight 
of cable
kg/km
 Max.DC
Resistance
 of Conductor
at 20 ºCΩ/km
Current Rating  (A)
Direct 
in ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv3×4+1×2.51.0
0.8
0.21.81.815173042154813914.61
7.41
7.41
12.1
38302620
3×6+1×41.0
1.0
0.21.81.816193982615934573.08
4.61
4.61
7.41
47393226
3×10+1×61.0
1.0
0.21.81.817215463287785601.83
3.08
3.08
4.61
65504635
3×16+1×101.0
1.0
0.21.81.8212479044110456961.15
1.83
1.91
3.08
84656047
3×25+1×161.2
1.0
0.21.81.82527114860114999020.727
1.15
1.20
1.91
110847760
3×25+1×161.2
1.0
0.21.81.826291439712176310360.524
1.15
0.868
1.91
1301009574
3×50+1×251.4
1.2
0.51.91.927302008955261715640.387
0.727
0.641
1.20
15512011590
3×70+1×351.4
1.2
0.52.02.0303427181245337219240.268
0.524
0.443
0.868
195150145115
3×95+1×501.6
1.4
0.52.22.2353836571644441524250.193
0.387
0.320
0.641
230185185140
3×120+1×701.6
1.4
0.52.32.3384145681983542328430.153
0.268
0.253
0.443
260205210165
3×150+1×701.8
1.4
0.52.42.4424554991373645233300.124
0.268
0.206
0.443
300230245190
3×185+1×952.0
1.6
0.52.62.6465068442936786239890.0981
0.193
0.164
0.320
335260280215
3×240+1×1202.2
1.6
0.52.82.8525687373687993848880.0754
0.153
0.125
0.253
390300335260

Four-core Same Cross Section PVC Insulated PVC Sheathed Power Cable
AC Rated
 Voltage
Nom. 
Cross
section
mm2
Nom.
 insulation
 thickness 
mm
Steel
tape
thickness
mm
Nom. sheath 
thickness mm
Approx OD
 of cable
mm
Apporx weight of cable
kg/km
 Max.DC
Resistance
 of Conductor
at 20 ºCΩ/km
Current Rating  (A)
Direct in 
ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv1.0 0.2 1.8 1.8 15 18 328 229 497 398 4.61 7.41 38 30 26 20 
1.0 0.2 1.8 1.8 17 19 420 272 604 456 3.08 4.61 47 39 32 26 
10 1.0 0.2 1.8 1.8 19 22 598 357 813 570 1.83 3.08 65 50 45 35 
16 1.0 0.2 1.8 1.8 22 24 852 467 1096 709 1.15 1.91 84 65 60 47 
25 1.2 0.2 1.8 1.8 25 28 1247 645 1538 933 0.727 1.20 110 84 77 60 
35 1.2 0.5 1.8 1.8 28 31 1635 793 2245 1397 0.524 0.868 130 100 95 74 
50 1.4 0.5 1.9 2.0 29 33 2256 1053 2862 1676 0.387 0.641 155 120 115 90 
70 1.4 0.5 2.1 2.1 32 36 3044 1360 3726 2047 0.268 0.443 195 150 145 115 
95 1.6 0.5 2.2 2.3 36 41 4073 1789 4898 2597 0.193 0.320 230 185 185 140 
120 1.6 0.5 2.3 2.4 40 44 5032 2147 5926 3021 0.153 0.253 260 205 210 165 
150 1.8 0.5 2.5 2.6 44 48 6293 2687 7236 3641 0.124 0.206 300 230 245190 
185 2.0 0.5 2.7 2.7 49 53 7733 3284 8832 4352 0.0991 0.164 335 260 280215 
240 2.2 0.5 2.8 2.9 55 59 9933 4162 11059 5307 0.0754 0.125 390 300 335260 
(4+1) -core PVC Insulated PVC Sheathed Power Cable
AC 
Rated
 Voltage
Nom. 
Cross-
section
mm2
Nom. 
insulation
 thickness
 mm
Steel
tape
thickness
mm
Nom. sheath
 thickness     mm
Approx 
OD of cable
mm
Apporx weight 
of cable
kg/km
Max.DC 
Resistance
 of Conductor
at 20 ºCΩ/km
Current Rating  (A)
Direct in
 ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv4×4+1×2.51.0
0.8
0.21.8-16-369-255-4.61
7.41
7.41
12.1
38302620
4×6+1×41.0
1.0
0.21.8-18-483-310-3.08
4.61
4.61
7.41
47393226
4×10+1×61.0
1.0
0.21.81.820236779563996711.83
3.08
3.08
4.61
65504635
4×16+1×101.0
1.0
0.21.81.8232696812905238321.15
1.83
1.91
3.08
84656047
4×25+1×161.2
1.0
0.21.81.827291432174273410240.727
1.15
1.20
1.91
110847760
4×35+1×161.2
1.0
0.21.82.028321819255288115860.524
1.15
0.868
1.91
1301009574
4×50+1×251.4
1.2
0.51.92.0293425203173116717800.387
0.727
0.641
1.20
15512011590
4×70+1×351.4
1.2
0.52.02.1313533884118149421680.268
0.524
0.443
0.868
15150145115
4×95+1×501.6
1.4
0.52.12.2374045675430198227680.193
0.387
0.320
0.641
230185185140
4×120+1×701.6
1.4
0.52.22.3394256946590238831860.153
0.268
0.253
0.443
260205210165
4×150+1×701.8
1.4
0.52.42.4424669288150290040030.124
0.268
0.206
0.443
300230245190
4×185+1×952.0
1.6
0.52.72.7495286739940365447710.0991
0.093
0.164
0.320
335260280215
4×240+1×1202.2
1.6
0.52.82.8545811060130224568 0.075
40.153
0.125
0.253
390300335260


(3+2) -core PVC Insulated PVC Sheathed Power Cable
AC 
Rated 
Voltage
Nom. 
Cross-
section
mm2
Nom. 
insulation 
thickness
 mm
Steel
tape
thickness
mm
Nom. sheath 
thickness mm
Approx 
OD of cable
mm
Apporx weight
 of cable
kg/km
Max.DC 
Resistance
 of Conductor
at 20 ºCΩ/km
Current Rating  (A)
Direct in 
ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv3×4+2×2.51.0
0.8
0.21.81.816183362315334274.61      7.417.41       12.138302620
3×6+2×41.0
1.0
0.21.81.817204442846715103.08
4.61
4.61
7.41
47393226
4×10+2×61.0
1.0
0.21.81.820226163618756201.83
3.08
3.08
4.61
65504635
3×16+2×101.0
1.0
0.21.81.8232588347411817721.15
1.83
1.91
3.08
84656047
3×25+2×161.2
1.0
0.21.81.826291305662167010260.727
1.15
1.20
1.91
110847760
3×35+2×161.2
1.0
0.21.81.928321606782228614620.524
1.15
0.868
1.91
1301009574
3×50+2×251.4
1.2
0.51.92.0333622931090309518920.387
0.727
0.641
1.20
15512011590
4×70+2×351.4
1.2
0.52.12.1364030511367390322450.268
0.524
0.443
0.868
195150145115
3×95+2×501.6
1.4
0.52.22.3424641381824513228470.193
0.387
0.320
0.641
230185185140
3×120+2×701.6
1.4
0.52.42.4454952442238636233650.153
0.268
0.253
0.443
260205210165
3×150+2×701.8
1.4
0.52.52.6505462092662744639070.124
0.268
0.206
0.443
300230245190
3x185+2x952.0
1.6
0.52.72.7555977833304915647120.0991
0.093
0.164     0.320335260280215
3x240+2x1202.2
1.6
0.52.93.06266994341721151854740.0754
0.153
0.125     0.253390300335260

Five-core same Cross-Section PVC Insulated PVC Sheathed Power Cable
AC 
Rated 
Voltage
Nom. 
Cross-
section
mm2
Nom. 
insulation 
thickness
 mm
Steel
tape
thickness
mm
Nom. sheath 
thickness mm
Approx OD
 of cable
mm
Apporx weight
 of cable
kg/km
Max.DC 
Resistance
 of Conductor
at 20 ºCΩ/km
Current Rating  (A)
Direct in 
ground
Run in air
VV
VLV
V V22
VLV22
VV
VLV
V V22
VLV22
VVVLVV V22VLV22CuAlCuAlCuAl
0.6/1kv5×41.00.21.81.817194656202654574.617.4138302620
5×61.00.21.81.818216177803175303.084.6147393226
5×101.00.21.81.8212381510304467221.833.0865504535
5×161.00.21.81.82436116714756089061.151.9184656047
5×251.20.51.82.028321753231069616010.7271.20110847760
5×351.20.51.92.1313522772996113819370.5240.8681301009574
5×501.40.52.12.2364029183699142323120.3870.64115512011590
5×701.40.52.22.4414639824970185928910.2680.443195150145115
5×951.60.52.42.6475254386229250337150.1930.320230185185140
Workshop
LV PVC Power Cable Without Armoring
Produce Flow
LV PVC Power Cable Without Armoring
Packaging & Shipping

LV PVC Power Cable Without Armoring

 
Our Advantages

LV PVC Power Cable Without Armoring

Partial Export Areas:

LV PVC Power Cable Without Armoring
Related Products:
LV PVC Power Cable Without Armoring
 

FAQ

LV PVC Power Cable Without Armoring

More infos, pls click