China Rvv Fire Performance Cable Fire Resistant Cables, Find details about China Fire Performance Cable, Fire Resistant Cables from Rvv Fire Performance Cable Fire Resistant Cables
Our fire resistant cable range is designed to ensure that emergency systems in public buildings continue to operate in some of the most extreme fire conditions.
Our fire performance cables are specifically designed for augmented fire resistance in applications including the delivery of power and auxiliary control in fire alarm systems, voice alarm systems, and emergency lighting systems including those applications designed to meet BS5266. These cables will form part of the requirements of BS8519 for the installation of fire-resistant power and control cable systems for life safety and fire-fighting applications.
These fire resistant single core and multi-core cables are suitable for use within a number of Control Circuit categories. For added protection against the risk of mechanical damage, we supply robust Firetec 'Power' and 'Impact Power' cables, both of which are suitable for indoor and outdoor applications. The 'Impact Power' is designed to withstand direct impact and water jet pressure. For additional flexibility, we supply the FRF2 cable, a cable suitable for bending around complex corners and the single core Tubesafe cable as found in environments such as the London Underground network.
Other fire resistant cables in our fire performance range include Mineral Insulated copper cables (MICC), designed to offer the ultimate fire resistance and good protection against electromagnetic interference. These high temperature cables are manufactured without any plastic insulation and provide circuit integrity up to 950oC. They are also available with LSZH oversheathing in various colour options. These cables are principally used within hazardous and explosive environments or where corrosive chemicals may affect performance. The LSZH insulated cables hold LPCB-approval. Those without polymer oversheathing have ATEX approval and comply with the EU directives on working within hazardous or explosive environments.
Fire resistant single core and multicore cables - PH30 / PH60 / PH120 cable - fire rated
Fire proof cable duration | Applications | |
---|---|---|
PH30 | Fire rated 30 minutes | PH30 cables are suitable for emergency applications where the circuit must remain operational for up to 30 minutes |
PH60 | Fire rated 60 minutes (1 hour) | PH60 cables are used in emergency applications, in particular emergency lighting to BS5266 where longer circuit operation is required in the event of fire |
PH120 | Fire rated 120 minutes (2 hours) | PH120 cables are designed for installations requiring enhanced circuit integrity for up to 120 minutes, This includes complex or high-rise blocks of flats requiring a longer evacuation period. |
Standard fire resistance vs Enhanced fire resistance
Level | Manufacturing British standard | Applications |
---|---|---|
Standard fire resistance | BS7629-1, BS EN 50200 PH30, PH60 and PH120 | Fire resistant single core cables and multicore cables for BS5839-1 (most fire detection and fire alarm systems), BS5266 (emergency lighting and standard application circuits), and BS8519 (life safety and fire-fighting) category 1 control circuits. Where used under standard BS5839-1, standard fire-resisting cables should be considered to provide sufficient resistance to the effects of fire, with appropriate methods of support and jointing. |
Enhanced fire resistance | BS7629-1, BS8434-2, BS EN 50200 PH30, PH60 and PH120 | Enhanced fire resistant cables are used in most public or complex buildings requiring emergency systems to remain operational for a minimum of two hours (PH120) in compliance with BS8434-2 and BS8519 category 1 & 2 control circuits. They are used for unsprinklered buildings with phased evacuation, unsprinklered buildings in excess of 30 metres in height, and where the designer, specifier or enforcing authority determines it is necessary on the basis of fire risk. |
An important distinction exists between fire resistant cables and flame retardant cables, even though both of them are subjected to various fire performance tests in order to earn their respective classification. In brief, flame retardant cables are designed to resist the spread of fire into a new area. Fire resistant or fire rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions. The distinction between the two is crucial when it comes to maintaining critical circuits required for life safety or for a safe and immediate plant shutdown.
Fire resistant (fire rated) cables | Continues to operate in the presence of fire, hence their reference as Circuit Integrity cables, This includes PH30, PH60 and PH120 cables. |
Flame retardant cables | Fire performance limited to not propagating fire |
Eland Cables supplies a wide range of PVC cable products manufactured in accordance with various international standards. Some of the most commonly requested cables in our portfolio include:
Application overview | |
---|---|
Twin & Earth cable (624Y) | Mains electricity wiring |
Tri-rated cable | Switchgear and panel wire manufactured to UL, CSA and British Standard |
2491X cable (H05V-K / H07V-K) | Flexible panel wire |
218Y cable (H03VV-F) | Domestic and office power supply |
2192Y cable (H03VVH2-F) | General wiring in public areas |
309Y cable (H05V2V2-F) | Portable tools power supply |
318Y cable (H05VV-F) | Domestic appliance power supply |
318A cable (Arctic grade) | Low temperature resistant power supply |
6381Y cable | Power, lighting and internal wiring cable. Also suitable for AC and DC telecommunications applications. |
Twinflex cable | Battery cable |
Elevator flatform cable | For lifts and elevators |
BV/BVR Wires for Housing and Office with Good Quality
3C approval BV electrical wire cable with Copper core pvc insulasted is a fine and ideal cable with conductor of plain annealed copper wires,solid or stranded.These cables are used for general purpose,as building wire for power, lighting and control wire to electrical appliances,suitable for use in conduit and for fixed,protected installation. The cable can be of flame ratardance,fire resistance and other property.
BV cables have very good sales over the world,enjoying a very good reputation based on top quality,most competitive price and best service.
Technical Information:
1. Voltage: 300/500V,450/750V
2. Standard Applied: IEC 60227,VDE0285,GB/T 5023
3. Max.Operating Temperature: 70°C,can be 90°C,105°C as per requirment
4. Conductor:Copper wire,solid or stranded
5. Insulation:PVC
6.Range of Nominal cross section:0.50-95mm2
7. Jacket: without Jacket
8. Color: Black,Brown,Grey,Blue,Green/Yellow or orthers on request
9.Flame ratardance,fire resistance and other property can be available
10.Packing:100 meter/roll or as per requirement
11.Certification:ISO9001,RoHS,Reach,CCC,VDE,SAA,UL,CE,etc. 12.OME can be available
Specification
Type: Solid Type, Stranded Type, Flexible Type are available.
Size: 0.5-630mm2 , BV BVV BVR RV RVV,RVS
Length: 100M 200M 300M 500M/roll, Can make as your request.
Type | Cross Section(mm2) | Conductor Size(No. of Cores/Diameter) | Rated Voltage | Nominal Insulation Thickness(mm) | Reference Weight(kg/km) | Application |
Solid Type | 0.5 | 1/0.80 | 300/500V 450/750V | 0.6 | 8.0 | Solid, Hard,Suitable for fixed installation |
0.75 | 1/0.97 | 0.6 | 11.4 | |||
1 | 1/1.13 | 0.6 | 15.2 | |||
1.5 | 1/1.38 | 0.7 | 21 | |||
2.5 | 1/1.78 | 0.7 | 32 | |||
4 | 1/2.25 | 0.8 | 47 | |||
6 | 1/2.76 | 0.8 | 67 | |||
Stranded Type | 1.5 | 7/0.52 | 0.7 | 22 | Stranded, Flexible house wiring, Suitable for indoor applicant. | |
2.5 | 7/0.68 | 0.7 | 35 | |||
2.5 | 19/0.40 | 0.8 | 34 | |||
4 | 7/0.85 | 0.8 | 50 | |||
4 | 19/0.52 | 0.8 | 51 | |||
6 | 7/1.04 | 0.8 | 71 | |||
6 | 19/0.64 | 0.8 | 72 | |||
10 | 7/1.35 | 1.0 | 118 | |||
10 | 49/0.52 | 1.0 | 127 | |||
16 | 7/1.70 | 1.0 | 177 | |||
16 | 49/0.64 | 1.0 | 184 | |||
Flexible Type | 1.5 | 30/0.25 | 0.7 | 22 | Ultra Flexible, Soft Conductor, Suitable for small power equipment instrument. | |
2.5 | 49/0.25 | 0.8 | 34 | |||
4 | 56/0.30 | 0.8 | 49 | |||
6 | 84/0.30 | 0.8 | 70 | |||
10 | 77/0.40 | 1.0 | 117 | |||
16 | 119/0.40 | 1.0 | 168 | |||
25 | 189/0.40 | 1.2 | 265 | |||
... |
The cable can be of flame retardance, fire resistance, environment friendly or other property. OEM Available.
Parameter
1.Voltage Uo/U 300/500V 450/750V
2.Max. Permissible Continuous Operation Temperature of The Conductor: 70°C
Flame-retardant Can be reach 90°C or 105°C
3.The Ambient Temperature Under Installation Should Not Below 0°C
4.Impedance (ohms): 100±2ohm
Packaging Details: Packing Length:100m/roll, 200m/roll, 305m/roll, 500m/roll
Delivery Time:Normally within 10 days (detailly depend on the order quantity)
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.
Tel :+86 15039132763