Outdoor Grounding Wire (double tongue type)

China Outdoor Grounding Wire (double tongue type), Find details about China Reel Insulator, Silicone Rubber Insulator from Outdoor Grounding Wire (double tongue type)

Size of Bearing Capacity
70KN
Certification
ISO9001, IEC IEEE
Color
Grey
Brand
Oei Power
Trademark
OEIpower
Transport Package
Cartons Pallets Wooden Case
Specification
IEC IEEE
Origin
China Nanyang
HS Code
854690000
Size of Bearing Capacity
70KN
Certification
ISO9001, IEC IEEE
Color
Grey
Brand
Oei Power
Trademark
OEIpower
Transport Package
Cartons Pallets Wooden Case
Specification
IEC IEEE
Origin
China Nanyang
HS Code
854690000
Outdoor Grounding Wire (double tongue type)Outdoor Grounding Wire (double tongue type)Outdoor Grounding Wire (double tongue type)Outdoor Grounding Wire (double tongue type)Outdoor Grounding Wire (double tongue type)Outdoor Grounding Wire (double tongue type)Outdoor Grounding Wire (double tongue type)The Composite Insulators comply with the latest editions of and amendments to, the standards/specification listed below:
 
CSA                                   CANADIAN STANDARDS ASSOCIATION
 
G164-4                        -       Hot dip galvanizing of Irregular Shaped Articles
 
CAN/CSA                  -       Quality Assurance Program Categories 2299.3
 
ANSI                           -      AMERICAN NATIONAL STANDARDS INSTITUTE
 
C29.1                           -      American Standard Test Method For Electrical Power Insulators
 
C29.7                           -      American Standard For Wet-processed Porcelain Insulators (High Voltage Line Post Type) Electrical Power Insulators
 
987-1985                     -       IEEE Guide For Application of Composite Insulators
 
D750                            -      Recommended Practice for Operating Light and Weather Exposure Apparatus (Carbon Arc Type) For Artificial Weather Testing Of Rubber Compounds.
 
D1499                          -      Recommended Practice For Exposure of Plastics.
 
4Year of manufacture Specify data
5Name of the material Spiral type 13.2kV porcelain insulator, 1 "thread, ANSI 55-4.
6Insulation raw material Porcelain
7Class ANSI 55-4 Printed under the varnish of the insulator
8Gray color enamel ANSI 70 standard
 Standards  
9Applied standards ANSIC29.1, ANSI C29-5
10Quality certificate ISO 9001a recent
11Finished The entire surface of the insulator should be 
smooth and free of imperfections 
12Identification mark Printed under the varnish of the insulator in a legible and indelible way Manufacturer, Country of origin, Class 55-4.
 Dimensional characteristics  
13Distance from Fugainch(mm)9(228)
14Arc distanceinch(mm)5(127)
15Width of the insulating baseinch(mm)5.5(139.70)
16Width of the cuspinch(mm)≥4(101.60)
17Insulator heightinch(mm)≥4-3/8(111.25)
18Thread Diameterinch(mm)1(25.40)
19Thread length of the insulatorinch(mm)1-3/4(44.45) a 2(50.4)
20Weight Approx.kG(lb)1.63(3.6)
 Mechanical characteristics  
21Electromechanical resistancekN(Lbs)≥13(3,000)
 Electrical characteristics  
22Dry contour tension to 60 
HZ 
kV≥70
23Wet contour tension to 
60 HZ 
kV≥40
24Critical tension type impulse- PositivekV≥110
25Critical tension type impulse- NegativekV≥140
26Frequency drilling voltagekV95
27Maximun RIV at 1000 k HZµv5,500
28Packaging "The insulators should be packaged wooden fittings
highly resistant for your
transportation, storage and handling
"

 
D2240                          -      Rubber Properties, Durometer Hardness
 
D2565                          -      Recommended Practice For Operating Xenon-Arc Light And Water Exposure Apparatus Plastics.
The weathershed of the Post Insulators shall be manufactured from either Hydrated Alumina Ethylene Propylene Copolymer (EPM) as the primary constituent or Silicone Elastomers. The weathershead shall be injection moulded and brought to final cure state in one continuous process to prevent internal undercure or surface overcure. Additionally, the weathershead shall provide hydrophobic surface, even after exposure to tropical marine environment, ultra violent rays and moisture.
Core
 
5Name of the material "Reel porcelain insulator
3 "x 3-1 / 8", hole 1/16 ", ANSI
53-2
"
6Isolating material Porcelain
7Enamel Color Gray according to ANSI 70
8Class ANSI 53-2 Printed on the insulator
9Standards ANSI C29.3
10Quality certificate ISO-9001 or recent
11Finished The surface of the insulator at the end of the process should be smooth and free of 
defects. 
12Identification mark Printed under the varnish of the insulator legibly and indelibly 
manufacturer, country of origin, Class 
ANSI 53-2 
 Dimensional characteristics  
13Insulator heightinch(mm)3(76.2)
14External diameterinch(mm)3 1/9(79)
15Inside diameterinch(mm)17/24(18)
16Diameter of the neckinch(mm)1 71/92(45)
17Weightkg0.51(1.22)
 Electrical characteristics  
18Low to low frequency contouring voltage at 60 HZ 25
19Contour voltage at industrial frequency under horizontal 15
20Voltage of contour to industrial frequency under vertical rain 12
 Mechanical characteristics  
21Transverse Mechanical ResistancekN(lbs)13.3(2989)
22Packaging "The insulators should be packaged wooden fittings
highly resistant for your
transportation, storage and handling
"


The rod or the core is manufactured from Fibreglass, having 70-75 by weight of auxiliary aligned glass fibre bonded by an organic resin. The rod is either be cast or pultruded.
The end fittings are have the following properties:
 
i.          are compressed onto the Fibreglass rod member
ii.         are  not move relative to the central Fibreglass rod at applied loads equal to two times the rated Routine Test Load or maximum designed cantilever loads
iii.        are attracted to the rod after completion of all external heat processes used to cure or bond component parts.
 Outdoor Grounding Wire (double tongue type)
The insulator are  provided load limiting bases that will deform under longitudinal loading of more than 100% of the rated design cantilever load. 
Performance Characteristics
 
The Polymeric Insulators are meet the under listed performance characteristics.
 
 
             ITEM
 
                11kV
 
                33KV
 
Dry Flashover Withstand
 
                90kV      
 
                180kV
 
Wet flashover withstand
 
                70kV
 
                165kV
 
Positive Impulse Critical flashover
 
               145kV
 
                300kV
 
Maximum Radio Interference Voltage
 
Below 1micro volt
 
   Below 1 micro volt         
 
Design Tension Strength
 
                100kN
 
                 100kN
 
Residual Strength after Power Arc
 
                  80kN
 
                   80kN
 
Mechanical Proof Test Load
 
                 45kN
 
                   45kN
 
Maximum Sustained Load
 
                 34kN
 
                   34kN
 
Design Torque Rating
 
                83 Nm
 
                   83 Nm
 
 
The insulator are suitable for accepting both aluminium and copper conductors having cross-sectional areas ranging from 35mm2 to 265mm2. The insulators are designed for mounting on the angle and channel crossarms specified in Specification E14
 
All exposed ferrous part shall be treated against corrosion. Treatment by hot dip galvanizing is preferable.