Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements

China Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements, Find details about China Fan, Industrial Fan from Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements

Model NO.
MTX-T
Total Pressure
11590-21931PA
Motor Power
15-90kw,1400kw or Higher
Speed
2950rpm
Driven Type
Direct/Belt/Coupling Driven
Running Mode
Uni-Directional and Reversible
Application
Abrasive/Kiln/Boiler/Power Plant/Sewage Treatment
Start Type
Soft Starter/Frequency Starter
Voltage
380V/440V/660V
Frequency
50Hz/60Hz
Electric Current Type
AC
Fan Effect
Air/Smoke Extraction/Ventilation
Dimension
According to Order
Color
Red/White/Grey/Customized
Warranty Period
One Year
Trademark
Motexo
Transport Package
Wooden Case
Specification
Centrifugal fan wooden package
Origin
China
HS Code
841459
Model NO.
MTX-T
Total Pressure
11590-21931PA
Motor Power
15-90kw,1400kw or Higher
Speed
2950rpm
Driven Type
Direct/Belt/Coupling Driven
Running Mode
Uni-Directional and Reversible
Application
Abrasive/Kiln/Boiler/Power Plant/Sewage Treatment
Start Type
Soft Starter/Frequency Starter
Voltage
380V/440V/660V
Frequency
50Hz/60Hz
Electric Current Type
AC
Fan Effect
Air/Smoke Extraction/Ventilation
Dimension
According to Order
Color
Red/White/Grey/Customized
Warranty Period
One Year
Trademark
Motexo
Transport Package
Wooden Case
Specification
Centrifugal fan wooden package
Origin
China
HS Code
841459

Motexo Vent--
CENTRIFUGAL BLOWER FAN

APPLICATIONS

MTX-T series boiler pass induced draft centrifugal blower fan is mainly applicable to the ventilation
system for 2-670t / h steam boiler in thermal power plant. The MTX-T series can also be used
in industries ventilation and general ventilation without other special requirements required.

GENERAL SPECIFICATIONS
 

Ventilator conveyor medium is the air, the maximum temperature shall not exceed 80 ºC;
induced draft fan for the media is flue gas, the maximum temperature shall not exceed 250 ºC.

Dust removal device must be installed in the front of fan to minimize the amount
of dust into the fan. According to the usage of general power plants, the efficiency of equipped
dust collector shall not be less than 85%.

These fans are produced for customers special requests.If the customer has other requirements
for pressure and air volume what is not included in the following list, please contact our
technicians to design and select the appropriate fan.

  • Can be produced between Ø680 mm - Ø900mm with requested diameter and variable blade angels.
  • Air Volume is up to 9039m³/h (2.52m³/s)
  • Static Pressure is up to 21931 Pa.

CONSTRUCTION (FAN CASING)

The casing is formed from the Q235 steel sheet to stainless steel SS316 or 304 with integral supports.
The grey/red/white/orange paint finish is applied after production, optional hot dip galvanization,
furnace paint or epoxy paint is available. On fan casing there is Aerodynmical round Inlet

 

IMPELLER

Impellers are produced from Q235 Steel Sheet,stainless steel, ZAlSi7Mn Aluminium or FRP.

Static and dynamic vibration defects recovered after production according to appropriate ISO norm.

Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements
 

DRIVEN TYPE
Direct driven,belt driven,coupling driven.

 

OPTIONAL ACCESSORIES

Inlet silencer or outlet silencer,flexible connecter,air shutter.

OUTLET ANGLE
You can check below to select outlet angle that meet your demands.
Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements



View more details and technical sheet of our centrifugal fan blower,kindly please contact us to get latest catalog.


Customer Cases---Centrifugal Fan Environmental Project Worldwide
We've been working with many project in Uganda,Indonesia, Myanmar,Peru,Pakistan and
other countries for sewage treatment project,Steel plant boiler drafting project,
Hydro Electric Power Plant and tunnel&mining project.

We understand the harsh environments in which fans are used.
Motexo fans will meet and exceed the demands of your industry engineering,
infrastruction project, mining/tunnel project and other environment project.


Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements



Production Workshop

Motexo Fan manufacture 300 series and more than 1,400 kinds of industrial fans.
All include heavy-duty designs for industrial applications.

We have individual workshop for roots blower,centrifugal fans&blowers,
maintaining,axial fan,welding and assembling.

For more info please direct check our website--motexco.en.made-in-china.com

Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements


Production&Testing Equipment

Not only we can produce large batch of small fan, we have processing capability to produce heavy
duty blowers like above 3.5m high. 
We adopt the best technology in all aspects of industrial blower,
such as shot blasting, sand blasting, all the paint process, welding process, etc.

Stoving vanish looks brighter than water paint( ordinary painting color). It has more than 200 sets of fine, large and rare processing equipment, and has a high-tech resin sand casting production line.

Our equipment is generally used for power plants, environmental protection plants, coal plants, and so on.
It requires high technology and workmanship.


Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements

Centrifugal Fan Blower Equiped with Frequency Control Panel/Soft Starter
Low Energy-Consuming Centrifugal Exhaust Fan to Suit Exact Requirements