Product Description

overhead aluminum aerial bundle cable , duplex/triplex service drop cable , aluminum cable

Application

AAC conductor electronic cable
AAC conductor electronic cable is used primarily for 600V overhead secondary distribution lines, it's not an electrically insulated conductor and is treated as bare conductor when installed

 

 

duplex service drop
1, Application
Aerial Bundle Cable aluminum strand electronic cable is used to supply 120 volt aerial service for temporary serivce at construction sites , outdoor or street lighting . For service at 600 volt or lower at a conductor temperature of 75 degree maximum
2, Construction
Concentric strand or compressed 1350-H19 conductor , polyethylene or crosslinked polyethylene insulation , aerial bundle cable aluminum strand electrical wire concentric strand AAC , ACSR , or 6201 alloy neutral messenger

Code*WordPhase conductorBare Neutral MessageNominal lay LengthWeight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
StrandingInsul
Thick(Mils)
Size
(AWG)
StrandingRated
Strength
(lbs.)
inchesXLPEPEXLPEPE
AAC Neutral-messenger
Pekingese61456756310.3661618570
Collie67456756310.3664648570
Dachshund41454788110.36929211590
Spaniel47454788110.36969611590
Doberman274527135014.88147147150120
Malemute1/09601/07199014.88234234205160

3, Standards
ASTM B-230, B-231, B-232 and B-399
ICEA S-76-474
4, Note
The Designed sizes of aerial bundle cable aluminum strand electrical wire are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201Conductor temperature of 75 degree, ambient temperature of 40 degree, emissivity 0.9, 2ft/sec wind in sun
Packaging: available in 500ft coils and in long lengths on reels
The data is approximate and subject to mormal manufacturing tolerances
To determine current ampacity by conductor size, please consult the national electric code, latest edition


triplex service drop
1, Application
Aerial Bundle Cable aluminum strand electrical wire is used to supply power from the utility's lines to consumer's weatherhead, for service at 600 volt or less (phase to phase) at a conductor temperature of 75 degree maximum for polyethylene insulation or 90 degree maximum for crosslinked insulation
2, Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, aerial bundle cable concentric strand AAC, ACSR or 6210 alloy neutral messenger
3, Standards
ASTM B-230, B-231, B-232 and B-339
ICEA S-76-474

 

quadruplex service drop
1, Application
Aerial Bundle Cable aluminum strand electrical wire is used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made, to be used at voltage of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 degree for polyethylene insulated conductor or 90 degree for crosslinked polyethylene(XLPE) inulated conductors
2, Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum, Insulated with either polyethylene or crosslinked polyethylene , neutral messengers are concentrically stranded 6201, AAC, or ACSR , one conductor is manufactured with an extruded ridge for phase identification
3, Specifications
Quadruplex service drop of aerial bundle cable meets or exceeds the following ASTM
specifications:
B-230 aluminum wire , 1350-H19 for electrical purpose
B-231 aluminum conductors, concentric-lay-stranded
B-232 aluminum conductors, concentric-lay-stranded , coated steel reinforced (ACSR)
B-399 concentric-lay-stranded, 6201-T81 aluminum
Service Drop Cable meets or exceeds all applicable requirements of ICEA S-79-474
4, Note
The designed sizes of aerial bundle cable aluminum strand electrical wire are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201Conductor temperature of 90 degree for XLPE , 75 degree for poly , ambient temperature of 40 degree , emissivity 0.9, 2ft/sec , wind in sun
To determine current ampacity by conductor size , please consult the national electric code, latest edition

Construction

Code WordPhase conductorBare Neutral MessengerNominal Lay LengthWeight Per 1000ft. (lbs.)Allowable Ampacities+

Size

(AWG)

Stranding

Insul. Thick.

(Mils)

Size

(AWG)

Stranding

Rated Strength

(lbs.)

inchesXLPEPEXLPEPE
AAC Neutral-messenger
Pekingese61456756310.3661618570
Collie67456756310.3664648570
Dachshund41454788110.36929211590
Spaniel47454788110.36969611590
Doberman274527135014.88147147150120
Malemute1/09601/07199014.88234234205160
             

 QQ20170626164454QQ20170626164525QQ20170626164300Overhead Aluminum Aerial Bundle Cable Triplex Service Drop Cable,