Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

China Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan, Find details about China Underground Ventilation Fans, Underground Ventilation Duct from Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Machine Number
8
Speed R/Min
1450
Power (Kw)
5.5
Air Volume M3/S
4.4-9.5
Full Pressure PA
108-497
Trademark
china coal
Transport Package
Standarad Package
Specification
mm
Origin
China
Machine Number
8
Speed R/Min
1450
Power (Kw)
5.5
Air Volume M3/S
4.4-9.5
Full Pressure PA
108-497
Trademark
china coal
Transport Package
Standarad Package
Specification
mm
Origin
China

Introduction Of Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

K40 Series mine energy-saving fan is specially designed according to the needs of various non-coal mines such as metallurgy, nonferrous metals, gold, chemicals, building materials and nuclear industry. It can be used as the main fan and auxiliary fan, which can be installed on the surface or in the underground. It is suitable for combined operation of multiple fans. It is an ideal machine station fan for all levels of multi-stage multi-stage machine station ventilation system. It is also suitable for ventilation in large workshops, tunnels, civil air defense projects and other occasions.zmwm02
Main features of the fan:
1. The twisted airfoil blade is used, the aerodynamic efficiency is high, and the energy saving effect is extremely remarkable.
2, various performance, complete specifications, can be well matched with a variety of resistance and airflow type ventilation network, can maintain long-term efficient operation.
3. With steady flow ring device, there is no hump in the characteristic curve, no risk of surge, safe and stable operation under any resistance state, and suitable for combined operation of multiple fans.
4. The structure of the motor and the impeller is directly connected, the overall stability is good, the installation is convenient, the maintenance is easy, and the device has low resistance.
5, compact structure, good moisture resistance. The main body of the fan is made of steel plate and section steel. The blade is made of steel plate material. It is hollow, and the blade and the whole machine have high strength. It has strong ability to resist downhole blasting shock wave. It can be installed on the surface and is suitable for installation in underground. It is especially suitable as a multi-stage machine. The station fan of the station ventilation system.
6, can reverse the wind, the wind rate is greater than 60%, no need to build a counter-wind.
7. The blade installation angle is adjustable, and the fan condition can be adjusted at any time according to the changes in mine production.
8. The amount of civil works is small, which can save a lot of investment.
9. The noise is low.

Parameter Of Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Fan modelMachine numberSpeed r/minPower (kW)Air volume m3/sFull pressure Pa
K40-4-NO8#Fan814505.54.4-9.5108-497
K40-4-NO9#Fan91450116.2-13.5136-629
K40-4-NO10#Fan101450158.5-18.6168-776
K40-4-NO11#Fan1114503011.3-24.7203-9390
K40-4-NO12#Fan1214503714.7-32.1242-1118
K40-4-NO13#Fan1314505518.7-40.8284-1312
K40-4-NO14#Fan1414509023.4-50.9329-1521
K40-4-NO15#Fan15145011028.7-62.6378-1746
K40-6-NO7#Fan79801.12.0-4.338-174
K40-6-NO8#Fan89802.23.0-6.449-227
K40-6-NO9#Fan998034.2-9.162-287
K40-6-NO10#Fan109805.55.8-12.577-355
K40-6-NO11#Fan119807.57.7-16.793-429
K40-6-NO12#Fan12980159.9-21.7111-510
K40-6-NO13#Fan1398018.512.6-27.5130-599
K40-6-NO14#Fan149803015.8-34.4150-695
K40-6-NO15#Fan159803719.4-42.3173-798
K40-6-NO16#Fan169805523.6-51.4197-908
K40-6-NO17#Fan179807528.3-61.6222-908
K40-6-NO18#Fan189809033.6-73.1249-1149
K40-6-NO19#Fan1998011039.5-86.0277-1280
K40-6-NO20#Fan2098016046.0-100.3307-1418
K40-6-NO21#Fan2198020053.3-116.1339-1563
K40-6-NO22#Fan2298025061.3-113.4372-1716
K40-8-NO11#Fan1173045.7-12.452-238
K40-8-NO12#Fan127305.57.4-16.161-283
K40-8-NO13#Fan137307.59.4-20.572-332
K40-8-NO14#Fan147301111.8-25.684-386
K40-8-NO15#Fan157301514.5-31.596-443
K40-8-NO16#Fan167302217.6-38.3109-504
K40-8-NO17#Fan177303021.1-45.9123-568
K40-8-NO18#Fan187303725.0-54.5138-637
K40-8-NO19#Fan197305529.4-64.1154-710
K40-8-NO20#Fan207307534.3-74.7170-787
K40-8-NO21#Fan217309039.7-86.5188-867
K40-8-NO22#Fan2273011045.7-99.4206-952
K40-8-NO23#Fan2373013252.2-113.6225-1041
K40-8-NO24#Fan2473016059.3-129.1245-1133
K40-8-NO25#Fan2573020067.0-146266-1229
K40-8-NO26#Fan2673025075.4-164.2288-1330
 

Photos Of Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Underground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction Fan