AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump

China AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump, Find details about China Heat Exchanger, Brazed Heat Exchanger from AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump

Model NO.
AC30 Cbh16 AC70 AC230DQ AC240DQ
Test Pressure
4.5/6.7 Mpa
Volum Pr Channel
0.094 L
Exchange Area (M2)
0.05(N-2)
Max Temperature
225c
Trademark
Baode
Transport Package
Standard Plywood Box
Specification
ISO9001, CE, UL, WRAS, rohs and etc.
Origin
China
HS Code
8419500090
Model NO.
AC30 Cbh16 AC70 AC230DQ AC240DQ
Test Pressure
4.5/6.7 Mpa
Volum Pr Channel
0.094 L
Exchange Area (M2)
0.05(N-2)
Max Temperature
225c
Trademark
Baode
Transport Package
Standard Plywood Box
Specification
ISO9001, CE, UL, WRAS, rohs and etc.
Origin
China
HS Code
8419500090
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure SWEP Copper Brazed Plate Heat Exchanger for Heat Pump

Working principles

The heating surface consists of thin corrugated metal plates stacked on top of each other. Channels are formed between

the plates and corner ports are arranged so that the two media flow through alternate channels, always in counter-current

flow. The media are kept in the unit by a brazed seal around the edge of the plates. The contact points of the plates are also

brazed to withstand the pressure of the media handled.


Standard design

The plate pack is covered by cover plates. Connections are located in the front or rear cover plate. The channel plates are

corrugated to improve heat transfer efficiency and to make them rigid.


Standard materials

Cover plates: Stainless steel AISI 316

Connections: Stainless steel AISI 316

Plates: Stainless steel AISI 316

Brazing material: Copper

 

Particulars required for quotation

To enable Baode's representative to make a specific quotation, enquiries should be accompanied by the following particulars:

- flow rates or heat load required

- temperature program

- physical properties of liquids in question

- desired working pressure

- maximum permitted pressure drop
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat PumpAC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat PumpAC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat PumpAC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat PumpAC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat PumpAC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump
AC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat PumpAC30 Cbh16 AC70 AC230dq AC240dq F80 B120t B45 High Pressure Swep Copper Brazed Plate Heat Exchanger for Heat Pump