ICU Ventilator
Products
Home
ICU Ventilator
ICU Ventilator
China ICU Ventilator, Find details about China ICU, Ventilator from ICU Ventilator
Contact Now
Basic Info.
Model NO.
CWH-3010
Origin
China
Model NO.
CWH-3010
Origin
China
Product Desciption
Specification of CWH-3010 Ventilator
General requirements
1.1 Patient range: Support adult and pediatric;
1.2 Display: ≥12 inch high definition TFT colour screen (touchable), can display 3 types of waveform and loops in same screen;
1.3 Power: AC 100-242V, 50/60Hz, with back-up battery, can be used for more than 120 mins after fully charge;
1.4 Working type: Pneumatic driven,electronically controlled;
1.5 Pipeline input range: 0.28~0.6MPa;
1.6 Apply with Day/Night mode,Standby;
1.7 One-key lock for screen, avoid the mis-operation;
2. Ventilation mode and typical function
2.1 Standard ventilation mode: VCV, PCV, PSV, SIMV, APNEA (A/C), CPAP, SIMV/PSV, Bip, APRV,Manual mode etc;
2.2 Apply with Invasive and Non-invasive function;
2.3 Apply with pressure and flow trigger function;
2.4 Apply with Synchronous nebulization and humidify function. High flow oxygen remedy function;
3. Ventilator parameter
3.1 Tidal volume range: 20-2000ml
3.2 Breathing rate: 1-100bpm (1-40 bpm under SIMV);
3.3 Inspiration time: 0.2-12s
3.4 Pressure control/Pressure support:0~80cmH2O
3.5 Inspiration plateau: OFF, 1~50%
3.6 SIGH: OFF, 1~5/100
3.7 Electronic PEEP: OFF,3~40 cmH2O
3.8 CPAP:4~20cmH2O
3.9 O2 concentration: 21%~100%, continuously adjustable
3.10 Inspiration trigger sensitivity: Pressure: OFF, -20~0cmH2O (based on PEEP)
Flow:0.5~30L/min
4. Monitoring parameter
4.1 Self-test when start-up the machine: include pressure, flow, O2 sensor etc
4.2 Parameter monitoring:
-Tidal volume monitoring: VT for inhalation and exhalation;
-Pressure monitoring: Ppeak, Pmean, pressure control level,pressure support level ,PEEP, Pplateau, Peak Inspiratory Negative pressure ;
-Breathing rate monitoring: Total breathing rate, breathing rate for spontaneous breath, breathing rate for mechanical ventilation;
-Volume monitoring: minute volume, minute volume for spontaneous breath, minute leakage volume;
-Flow monitoring: maximum inspiration flow, maximum expiration flow;
-Resistance monitoring: inspiration resistance, expiration resistance;
-Gas monitoring: O2 concentration;
-Special monitoring: Flow trigger depth, Pressure trigger depth, Dynamic Compliance, Static compliance, RVR(RSBI);
Waveform monitoring: P-T,F-T,V-T waveform;
Loops monitoring: P-V, V-F,F-P loops;
Alarm: VT, MV , airway pressure, continuous pressure, breathing frequency, no connection of tubing, Apnea, O2 concentration,PEEP, O2 or Air failure, AC power failure, back-up battery low, machine fault, etc. Comprehensive 3 level alarm function include audible (adjustable), visual and flicking alarm.
5.Air compressor
5.1 Air compressor with same brand, main unit of compressor
5.2 Sustained flow: ≥45L/min
5.3 Export pressure: 0.4 Mpa
Contact Now
You Might Also Like
FDA Approved Lemborexant Sleep-Wake Disorders and Insomnia D......
Dmr Digital Two-Way Radio, UHF/VHF, Compatible with Mototrbo......
Multifunctional Shr Opt/RF Hair Removel Elight Birth Mark Re......
Air Lift D2300 2300lbs Rubber Air Spring Bag for Car Truck A......
Hot Feed Rubber Extruder with Ce
Single Girder Gantry Crane with Factory Price
D2w6y Cheap Manual Home Used ABS Crank Hospital Foldaway Bed
Old Style Wooden Treasure Box with Brass Latch Woodcraft
Arena PARA Gatos for Toilet Bentonite Cat Sand Pet Supply
Women A Line Short Knee Length Tutu Tulle Prom Party Skirt
G Single Screw Progressive Cavity Pump Self-Priming Slurry P......
700ml Round Shape Spirits Vodka Whisky Brandy Glass Bottle