Air Source Swimming Pool Heat Pump with R410 Refrigerant

China Air Source Swimming Pool Heat Pump with R410 Refrigerant, Find details and Price about China Swimming Pool Heat Pump, Heat Pump from Air Source Swimming Pool Heat Pump with R410 Refrigerant

Model NO.
CKFCRS-20II
Rated Outlet Hot Water Temperature
28 Degree
Maximumoutlet Hot Water Temperature
35 Degree
Compressor
SANYO
Refrigerant
R410A
Trademark
CEN
Transport Package
Carton with Plywood
Specification
CE
Origin
China
HS Code
8418612090
Model NO.
CKFCRS-20II
Rated Outlet Hot Water Temperature
28 Degree
Maximumoutlet Hot Water Temperature
35 Degree
Compressor
SANYO
Refrigerant
R410A
Trademark
CEN
Transport Package
Carton with Plywood
Specification
CE
Origin
China
HS Code
8418612090
 KONNEN SWIMMING POOL HEAT PUMP WATER HEATER:
* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R410a refrigerant;
* Stainless steel 304 for all fasteners, for side covers of evaporator;
* Preservative oil for copper tubes and all important part of cabinet;
* Chinese No.1 brand "Gimleo" Titanium tube heat exchanger;
* Japan "Saginomiya"  or "Sanhua" electronic expansion valve;
* "Sanhua" 4-way valve;
* Schneider AC contactor and relay;
* LCD controller;
* Delivery time: 20~25 days;
* Payment term: T/T 30% in advance and T/T 70% before delivery;
* Warranty time: 24 months after delivery.

We also supply OEM services!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
Air Source Swimming Pool Heat Pump with R410 Refrigerant
WHY US:
Air Source Swimming Pool Heat Pump with R410 Refrigerant
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
Air Source Swimming Pool Heat Pump with R410 Refrigerant
KONNEN NEW PROJECTS:
Air Source Swimming Pool Heat Pump with R410 Refrigerant
KONNEN HEAT PUMP LOADING:
Air Source Swimming Pool Heat Pump with R410 Refrigerant
Product features:
Air Source Swimming Pool Heat Pump with R410 Refrigerant

Parameters table:

S02H series(Swimming pool heat pump)                                                                                                                                                                                                        
 SP2.5PS-H2SP03PS-E3SP05PS-E5SP03P-E3SP05P-E5SP07P-E5SP10P-C24SP14P-C24SP20P-C48SP24P-C48SP30P-C48SP36P-C96SP40P-C96SP48P-C96
Rated heating capacitykW12 14 24 14 24 32 48 66 95 115 145 170 190 230 
Rated input powerkW2.11 2.45 4.14 2.37 4.06 5.69 8.14 11.57 16.10 19.49 25.11 29.31 32.76 39.65 
Rated input currentA10.82 12.56 21.23 4.55 7.80 10.92 15.63 22.21 30.91 37.42 48.21 56.28 62.90 76.13 
COP /5.59 5.71 5.80 5.91 5.91 5.62 5.90 5.70 5.90 5.90 5.77 5.80 5.80 5.80 
*Heating capacitykW12 20 12 20 25 40 52 80 95 120 145 160 190 
*Input powerkW1.80 2.30 3.88 2.33 3.80 4.87 7.62 9.98 15.36 18.20 22.81 27.83 30.48 36.19 
*Input currentA9.21 11.81 19.92 4.47 7.30 9.36 14.63 19.16 29.48 34.94 43.80 53.44 58.51 69.49 
*COP/5.01 5.21 5.15 5.15 5.26 5.13 5.25 5.21 5.21 5.22 5.26 5.21 5.25 5.25 
Maximum input powerkW2.74 3.19 5.38 3.08 5.28 7.40 10.58 15.04 20.93 25.34 32.64 38.10 42.59 51.55 
Maxmum input currentA14.05 16.33 27.60 5.92 10.13 14.20 20.32 28.88 40.19 48.65 62.67 73.16 81.77 98.97 
Rated hot water output temperature'ºC28 
Maximum hot water output temperatureºC35 
Power supply1N 220V/50Hz3N 380V/50Hz
CompressorTypeRotor typeFully closed scroll type
Start modeDirectly start
QuantitySet11111122223344
Water side heat exchangerTypeTitanium tube heat exchanger
Water flowM3/h5.07 6.02 10.32 6.02 10.32 13.76 20.6428.3840.8549.45 62.35 73.10 81.70 98.90 
 Water pressure dropKPa≤50≤70
Pipe sizeΦΦ50Φ50Φ50Φ50Φ50Φ50Φ50Φ50Φ50Φ90Φ90Φ110Φ110Φ110
Protections1. High pressure and low pressure protection, 
2. Anti-freezing protection, 
3. High temperature protection, 
4. Too big of the water temperature difference for outlet and inlet protection, 
5. Overload protection, 
6. Lack phase protection, 
7. Reverse phase protection,
8. Water flow protection etc.
NoiseDB(A)≤50≤55≤63≤55≤63≤63≤65≤68≤70≤72≤73≤74≤76≤78
Unit dimensionsmm1000×360×
630
700×700×
870
820×695×
1060
700×700×
870
820×695×
1060
820×695×
1060
1000×1000×18581000×1000×18581000×2050×19001000×2050×19001000×2050×19802000×2050×19802000×2050×19802000×2050×1980
WeightKG6410016010016016533536560066084086012251260
Testing condition: 1. Ambient temp.(DB/WB):24ºC/19ºC, Water temp.(In/Out):26ºC/28ºC
                             2. *Ambient temp.(DB/WB):15ºC/12ºC, Water temp.(In/Out):26ºC/28ºC
The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.
Swimming pool heat pump:
1. High cop and low price.
2. Low temperature works.
3. Low pollution and low noise.
4. Apply for world famous compressor.
5. Good looking and quality.

Advanced Titanium heat exchanger, heat pump technology, Economical & environmental-friendly. Topwind.

Features for Swimming pool heat pump(Topwind):
1) Long operating life: Using the advanced stainless steel/titanium metal water heat exchanger, which resists the erosion from chlorine in the water, creates a longer lifespan
2) Economical and high-efficiency: Using heat pump technology, compared with other ordinary hot water equipment (for example, combustion oil boilers, combustion gas boilers, electronic boilers and so on), it reduces operating costs by 65-80%, In addition it creates very little pollution.
3) Bright design, easy installation and replacement: Unit design separately for main model and water unit model, with water unit inside, avoiding freezing in the winter. The unit is remarkably compact, with pump and flow switch inside.
4) Advanced controlling: Extremely easy to control. The swimming pool heat pump unit is in the room, because of the mini-computer intelligent controlling and LCD display controller
5) Safety: Water and electricity are insulated, no open fire, no creepage
6) Quiet: Using the high-efficiency, low sound rotary or scroll compressor, low noise fan, high quality pump, creates an extremely quiet machine.
7) High technology heat exchangers: Due to brand and heat exchanger, it runs more efficiently 8) Safety: Protected from running in bad running circumstances, such as water temperature, compressor exhaust pressure, compressor temperature, evaporator temperature and so on.
 CKFCRS-12 I  CKFCRS-20 ICKFCRS-12 IICKFCRS-20 II  CKFCRS-40 IICKFCRS-80 IICKFCRS-120 II
CS02H030ACS02H050ACS02H030BCS02H050BCS02H100AS02H200ACS02H300A
Rated heating capacityKW122012204080120
Rated powerKW2.5 4.2 2.5 4.2 8.0 16.0 24.0 
Rated currentA12.6 21.4 4.7 7.8 15.0 30.1 45.1 
Maximum powerKW3.4 5.8 3.5 5.8 11.0 22.1 33.1 
Maximum currentA17.5 29.8 6.5 10.9 20.8 41.7 62.5 
Performance coefficientCOP4.8 4.8 4.8 4.8 5.0 5.0 5.0 
Rated hot water output temperature 28
Maximum hot water output temperature 35
Power supply1N 220V/50Hz3N 380V/50Hz
Alternative power supply(1N 208-230V/60Hz);  (1N 220-240V/50Hz);  (3N 220-240V/50Hz)
(3N 208-230V/60Hz);  (3N 380-415V/50Hz);  (3N 440-460V/60Hz);  (3N 380V/60Hz)
CompressorTypeFully closed scroll type
Start modeDirect
Water side heat exchangerTypeTitanium tube
Water flowM3/h3.4 5.7 3.4 5.7 11.5 22.9 34.4 
 Water pressure dropKPa50 
Pipe sizeDNDN50DN50DN50DN50DN50DN90DN90
Protections1. High and low pressure protection,    2. Anti-freeze protection,      3. High temperature protection,                                                                                                                  4. Overload protection,        5. Reverse of phase protection,  Lack of phase protection,  etc.
RefrigerantTypeR410A
Weight(KG)2.12.82.12.82.8×23.2×42.8×6
Noise≤DB ( A )55635563657070
Unit dimensionsLengthMM700772700772146020502641
WidthMM70068670068691011001000
HeightMM870938870938143019351930
WeightKG100160100160305810855
Note: 1.Hot water standard condition: use side initial water temperature 15   , end water temperature 28   ; dry-bulb temperature 20  , wet bulb temperature 15  .
2.The above parameters are based on Refrigearnt R410A, for parameters based on other refrigerant please contact us.