H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin

China H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin, Find details about China Manikin, Mannequin from H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin

Model NO.
H-ACLS850.
The Frequency of External Pacemaker
60times/Min
Airway Management
Standard Nasal,Oral and Tracheotomy Intubation etc
Keyword1
Training Manikin
Keyword2
Training Mannequin
Trademark
Healicom
Transport Package
Carton
Specification
CE ISO
Origin
Jiangsu, China
HS Code
9618000010
Model NO.
H-ACLS850.
The Frequency of External Pacemaker
60times/Min
Airway Management
Standard Nasal,Oral and Tracheotomy Intubation etc
Keyword1
Training Manikin
Keyword2
Training Mannequin
Trademark
Healicom
Transport Package
Carton
Specification
CE ISO
Origin
Jiangsu, China
HS Code
9618000010
H-ACLS850 Medical Human Nursing Training Dummy Manikin/Mannequin 

                                                            H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin
 

Product Introduction:
Complying with AHA (American Heart Association) 2010 guideline for CPR, H-ACLS850 provides ACLS (Advanced Cardiac Life Support) comprehensive training in first aid skills. The system consists of full-body manikin, AED machine, blood pressure measurement and data display of CPR. It provides a simple and practical ACLS training tool.

Features:
1.Airway management: standard nasal and oral intubation, tracheotomy intubation, supporting to head tilt and Jawthrust, audible feedback if pressure exerted on the teeth during intubation.
2.CPR: instantaneous displaying graphics of data, statistic report, sound directions related to CPR, result printing.
3.Simulating of a patient: the changes of pupils and carotid; the sounds of respiratory, moan, cough and vomit; more than 17 kinds of rhythm (access to 3/4 lead ECG monitoring); unilateral or bilateral bronchial obstruction; laryngospasm simulation.
4.Physical therapy: ECG monitoring via defibrillation connectors, the maximal energy of defibrillation is 360J; the frequency of external pacemaker is set to 60times/min, and the current threshold is 40mA.
5.Intravenous infusion and blood pressure measure training.
6.AED: automatically external defibrillation machine (only for training
use), providing electrode pad and electrode button.
7.Manikin's bare joint can rotate left and right, basically the same with the real human body size, and do foot care operations.
8.Manikin has interchangeable male and female external genitalia, can do catheterization operation training, bladder simulator is equipped inside, simulated urine can be injected into; if the operation is successful the simulated urine would flow out.

Standard components:
1.Full body manikin (1)
2.ACLS monitor (1)
3.ACLS converter (1)
4.Aluminum & plastic box (1)
5.CPR operation pad (1)
6.Exchangeable lung bag (5)
7.CPR face shield sheet (50pcs/box)
8.Temperature sensing print paper (2 roll)
9.H-S7 BP Training Arm (1)
10.Airway intubation parts (1)
11.Guide manual (1)

Alternative accessories
H-AED98F (Automatically External Defibrillation)
H-J980 Cardiac Defibrillators and Pacemakers Simulator
Real Cardiac Defibrillators and Pacemakers
H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin
Workshop:
H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin


   
H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin
                             H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin

                              H-Acls850 Medical Human Nursing Training Dummy Manikin/Mannequin