Patient Monitor (SpO2/ECG/NIBP/ TEMP /ETCO2) for Ambulance ICU Use

China Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use, Find details about China Patient Monitor, Hospital Equipment Monitor from Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use

Model NO.
PM5000
Screen
12.1 Inch, Color LCD Display
Transport Package
Carton
Specification
1pcs/carton
Origin
China Mainland
Model NO.
PM5000
Screen
12.1 Inch, Color LCD Display
Transport Package
Carton
Specification
1pcs/carton
Origin
China Mainland
Patient Monitor(SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use

Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use

Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use
Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use
Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use
Features:

1.Dual over-voltage protection makes the NIBP testing safer

2.PM5000 Patient Monitor can measure SpO2,pulse  rate,ECG,NIBP,temprature,ETCO2

3.Four avaliable cuff sizes will be comfortably fit a variety of patients

4.3-level visual/audio alarms with adjustable alarm ranges.

5.High capacity storage,power-off data protection.

6.Price is affordable in line with your budget.

 

 Technical Specifications: 

 

1. Parameters:

    SpO2, ECG, NIBP, TEMP, RESP, PR, RR. Optional Function: ETCO2 and internal printer.              

2. Power supply

  • AC power adapter, AC 85~265V/ 50Hz/60Hz;
  • Lithium battery,11.1V/4400mAh (Optional Double Batterys);

3. SpO2

  • Range: 0%-100%.
  • Accuracy: ±2% at 70-100%;<70%, undefined.

4. Pulse rate

  • Range: 30-250bpm.
  • Accuracy: ±2bpm at 30-250bpm.

5. NIBP (Non-Invasive Blood Pressure)   

  • Method:
  • Modes: Manual/Auto/Comtinuous  
  • Auto measure time: Adjustable  
  • Measurement range: 10-270mmHg 

6. ECG  

  • Lead mode:3-lead or 5-lead  
  • Lead selection:I;II;III,avR;avF;V  
  • Heart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpm  
  • ECG waveform:7 channals  
  • Accuracy: ±1 bpm or ±1%,which is greater  
  • S-T segment detection;measurement range: -2.0mv~2.0mv  
  • Alarm:Yes,audible and  visual alarm,alarm events review  

7. Respiration  

  • Method:RA-LL impedance  
  • Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm  
  • Apnca alarm:Yes

8. Temperature  

  • Range:0-50 °c  
  • Accuracy: ± 0.10 °c   
  • Channal:Dual-channel
9.Internal printer:
  • Equiped with internal printer, Be available to print 3 channels waveform.

10. Environment Specification:

  • Operatin Equiped with internal printer, Be available to print 3 channels waveform. g Temp.: 0 to 45°c
  • Storage Temp.: -20 to +60°c
  • Relative Humidity: 30 to 95%(Operating), 10 to 95%(Storage) 


Accsessories:
Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use




Packing :
Patient Monitor (SpO2/ECG/NIBP/TEMP/ETCO2) for Ambulance ICU Use