Karl Fischer Oil Moisture Testing Device

China Karl Fischer Oil Moisture Testing Device, Find details about China Oil Moisture Analyzer, Oil Moisture Tester from Karl Fischer Oil Moisture Testing Device

Operating Mode
Touch Screen
Heating Mode
Rapid Heating
Off Mode
Automatic
Trademark
Kolery
Transport Package
Standard Wooden Box
Origin
China
Operating Mode
Touch Screen
Heating Mode
Rapid Heating
Off Mode
Automatic
Trademark
Kolery
Transport Package
Standard Wooden Box
Origin
China
KR-605  Fully Automatic Karl Fischer Water Content Tester 


Application:

This KR-605 water content tester adopts the global recognized classical moisture testing method - Karl Fischer Coulometric Method which is the most accurate method with low cost. With the universal standard and analyzing method, it can quickly analyze the moisture content in liquid, solid and gas and directly display testing results within 60 seconds, with testing range from 0.0001%(1ppm) to 100%. Therefore, this testing method has been widely used in institutions and enterprises of petroleum, chemical industry, power, pharmaceuticals, pesticide, railways, research, etc.
 
Karl Fischer Oil Moisture Testing Device

The whole testing process is automatically controlled by this tester itself. Its auto-stirring and analyzing would be finished within 60seconds, and results would be displayed directly. Totally closed titration system avoids damage to operator from reagent. Equipped with 500ml Karl Fischer Reagent, which could test about 1000 times sample continuously, completely avoiding big deviations of other moisture testing method and thus improving quality index of products.  
 

            
Application Area:
LiquidChemical Industry:alcohols, ethers, esters, alkenes, benzenes, amines, organic solvents, phenols and other organic products applicable to Karl Fischer Method for determination
Petroleum and Power Industry: Insulation Oil, Transformer Oil, Turbine Oil, etc.
Pharmaceutical Industry :medicine materials
Pesticide Field:emulsifier
Other Industry:electrolyte of lithium battery
SolidVarious mineral salt, citric acid, explosives, paraffin and other solids with good solubility
GasNatural gas, liquefied gas, Freon, butadiene, chloromethane, etc. 



Features:

1. Electrolytic speed: microprocessors control electrolysis 
2. 6-inch (320X240 lattice) touch screen LCD display in English. Function of reagent failure prompt, extending the service time of it. 
3. Completely closed titration system avoids direct touch between people and the reagent as well as the influence of environmental humidity. 
4. The outer shell is made of high-quality cold-rolled steel plate with electrostatic sprayed surface, anti-corrosion and easy to clean.
5. Can connect with analytical balance (optional) to do the data communication and process.
6. Auto-control electrolysis current within 430mA ensures high sensitivity and fast analyzing speed.
7. Preinstalled with cubature (including 3 pieces of formula), statistical calculation (including average calculation, standard deviation calculation and rate of change calculation) and elementary arithmetic, with the advantages of auto-analysis and calculation.
8. Automatically tests the sample, analyzes and displays results, and calculates the average value of several times of test.
9. Powerful storage function, the measurement results automatically stored 1000, easy to check historical records.
10. Automatically calculates and prints the following content: ug / ppm / percentage / mg/L / sample number / experimenter / testing date, etc. 
11. Network management available by connection with laptop or computer communications through USB or RS232 interface.
12. Multilanguage display available. The program of tester can be upgraded accordingly if related national standard is revised. 

Technical Parameters:
Method of Display240X128 lattice touch screen LCD with English display
Method of TestingMPU controlled electrolysis(Karl Fischer Coulometric Method)
Rate of Electrolysis2.4 mgH2O/min
Electrolysis CurrentAuto-control within 430mA
Testing Range0.01ugH2O-200mgH2O
Water Content Range0.0001%(1ppm)-100%
Sensitivity0.01ugH2O
AccuracyWater Content: 1ugH2O-1000ugH2O; Deviations≤±3ug,
Water Content: >1000ugH2O; Deviations≤±0.2%
(excluding deviations of sample injection)
Drift CompensationAuto-control via MPU
Stirring SpeedAdjustable and steerable
End-point IndicationLCD display /output via printing / voice warning / end-point indication light
Data InputInput via touch screen
Sample NumberNumbered by users
Calendar/Clockautomatic display and print analyzing time and date
Self-checkingBreakdown self-checking
Special FunctionWork independently or connected with laptop or other computers
Power Consumption<40W
Dimension360×310×135mm
Working EnvironmentTemperature: 5ºC-40ºC,Humidity: <85%
Power SupplyAC220V±10% 50HZ±2.5HZ
WeightAbout 6kg

Standards compliant:

GB/T 6283-2008 Determination of moisture content in chemical products - Karl Fischer method.
ASTM E1064-2008 Karl Fischer Coulometric Titration for Determination of Water Content in Organic Liquids.
GB/T 7600-1987 Determination of moisture content of transformer oil during operation (Coulomb method).
ASTM D4928-00 (2010) Karl Fischer Coulometric Titration for Determination of Water Content in Crude Oil.
ASTM D6304-2007 Karl Fischer Coulometric Titration for Determination of Water Content in Petroleum Products, Lubricating Oils and Additives.
ISO 10337-1997 Determination of moisture content of crude oils Karl Fischer Coulometric titration.
GB/T 11146-2009 Determination of crude oil water content Karl Fischer Coulometric titration.
GB/T 3727-2003 Determination of trace water in ethylene and propylene for industrial use.
GB/T 5074-1985 Microcoulometric method for determination of moisture content of coking products.
GB/T 6023-2008 Determination of trace water in industrial butadiene Karl Fischer Coulometric.
GB/T 7376-2008 Determination of trace moisture in industrial fluoroalkanes - Karl Fischer method.
GB/T 18619.1-2002 Determination of water content in natural gas - Karl Fischer Coulomb method.
GB/T 18826-2002 Industrial 1,1,1,2-tetrafluoroethane HFC-134a.
SH/T 0246-1992 Determination of water content in light petroleum products (electricity method).
SH/T 0255-1992 Additives and additives containing lubricants - Determination of moisture (electricity method).
ASTM E1064-2008 Karl Fischer Coulometric Titration for Determination of Water Content in Organic Liquids.
ASTM D4928-00 (2010) Karl Fischer Coulometric Titration for Determination of Water Content in Crude Oil.



 

About Kolery Instrument
 

Located at Chongqing - a national municipality as well as southwest electromechanical manufacturing center, Kolery has many years of experience in the field of petroleum laboratory equipment solutions. Our company is mainly engaged in petrochemical analysis instruments design and produce, like karl fishcher moisture analyzer, Kinematic Viscometer, oil flash point tester, petroleum distillation machine etc. We have our own factory, and our products have good competitiveness in both of quality and price. As we understand the importance of the lab equipment quality to experimental analysis, Kolery has been committed to providing high-quality oil lab instruments to meet the customer's pursuit of accurate experimental results. We will recommend the most suitable product model based on the customer's requirements on technical parameters and experimental results. In addition to the expertise petroleum and oil analysis products, we are also familiar with the entire foreign trade process, and can quickly resolve various problems encountered by customers to ensure that trade can be proceed smoothly during the delivery period requested by customers.
Karl Fischer Oil Moisture Testing Device

 

Karl Fischer Oil Moisture Testing Device
Karl Fischer Oil Moisture Testing Device
Karl Fischer Oil Moisture Testing Device

 

Karl Fischer Oil Moisture Testing Device
Karl Fischer Oil Moisture Testing Device






FQA

Q: What are the available delivery methods?

A: Our port location: Shanghai, Chongqing or other main ports of China

  Delivery methods: by sea, by air, by truck, by express

  Delivery range: worldwide

Q: How long is the probable delivery date?

A: Delivery time is differs with order quantity, technical parameters requirements, etc. For most of our oil testing equipment and other lab equipment, like halogen moisture tester, spectrophotometers, the delivery date is about 3-7 business days. Please contact with us for more details.

Q: What are the available payment methods?

A: Payment methods: By T/T, L/C, Western Union, Paypal, etc.

  Payment terms: Generally, for small order T/T 100% advanced, we also accept T/T 40% advanced, the balance paid by T/T when the machine is ready. For big order, we can accept 100% irrevocable L/C at sight. 

Q: How long is the warranty period?

A: We warrants most of machines supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years from the time customer receives the goods. For some items, we offer 2 years warranty. Please contact us for details about this. 

Q: What's the mini order quantity?

A: MOQ: 1 unit/set


Packing and Shipping

Karl Fischer Oil Moisture Testing Device
1. Delivery time: for most of our products, it takes about 3-5 business days. We will do all test before shipping out to make sure goods arrive you in good condition.

2. We can ship by air, by sea, by express, by land. We can also use your pointed forwarder.

3.Packing: We use export wooden case for most of our products.

 


Payment Term
 

MOQ1 Set
Trade TermsEXW, FOB, CIF, CFR
Payment TermsT/T, L/C
Port of LoadingAny Port of China
Packing MethodInternaional Standard Wooden Case
Transportation MethodBy Sea, By Land, By Air, By Express
Supply Capability200 Sets/Month
 

 

After Sales Service 

* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 8 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.