China 10KV Output Transformer Insulation Capacitance and Tan Delta Tester, Find details about China Capacitance Tester, Dissipation Factor Tester from 10KV Output Transformer Insulation Capacitance and Tan Delta Tester
Working conditions | -15ºC~40ºC | RH < 80% | ||
Anti-interference method | Frequency conversion | |||
Power supply | AC 220V±10% | Generator can be used. | ||
High voltage output | 0.5KV~10KV | Every 0.1kV | ||
Accuracy | 2% | |||
Maximum Current | 200mA | |||
Capacity | 1500VA | |||
Self-excitation power | AC 0~50V/15A | 45Hz/55Hz | ||
Resolution | tgδ: 0.001% | Cx: 0.01pF | ||
Accuracy | tgδ: ± (Reading*1.0% + 0.040%) Cx: ± (Reading*1.0% + 1.00pF) | |||
Measuring range | tgδ | Without limit | ||
Cx | 15pF < Cx < 300nF | |||
10kV | Cx < 60nF | |||
5kV | Cx < 150 nF | |||
1kV | Cx < 300 nF | |||
CVT Test | Cx < 300 nF | |||
CVT transformation ratio | Range: 10~10000 Accuracy: 0.1% Resolution: 0.01 | |||
Dimensions | 430(L)*330(W)*330(H) mm | |||
Storage capacity | 80 groups. (USB disk storage is supportable.) | |||
Weight | Control unit:27kg (carrying box included.) Accessories:6kg (carrying box included.) |