1. Low initial resistance
2. Large dust holding capacity
3. Flexible
4. Outlet side with net or cloth mesh to reinforce
Application: Capturing 1-10μ M particles, especially for the top part of spray booth, prefiltration mesh to reinforce through air filter system, diffluent equally
Type: Supply pads or rolls size
Media: Synthetic fiber with gradual density,
With surface adhesive treatment
EN779 class: F5
Average arrestance: 96%(ASHRAE52.1-1992)
Average efficiency: 45%-55 %(ASHRAE52.1-1992)
EUROVENT4/5 class: EU5
DIN53438 Non-flammability Standard: F1
Final resistance: (suggested) 400Pa
Max. Dust holding capacity: 450g/square
Temperature resistance: 100º C
Instant temperature: ≤ 120º C
Specification: Within 3.6 m width; Adjustable length. Make according to customer's order. General stock: 1.6m*14m, 1.6m*21m, 2.0m*12m, 2.0m*21m.
General Description | surface addhesive treatment Ceiling Filter with TC Fabric |
Weight | 450G/M² |
Thickness | 22MM |
Air Flow Rate | 936M ³ /H |
Initial Resistance | 23pa |
Final Resistance | 400pa |
Media Arrestance | 93.5% |
Air Velocity | 0.26m/s |
Dust Holding | 385G/sqm |
Max Temperature | 120 º C |
Filtration Class | F5 (DIN 24185) |
Flame Resistance | F1 (DIN 53438) |