China Tension and Compression Force Load Cell, Find details about China S Type Load Cell/S Beam Load Cell, Crane Scale Load Cell from Tension and Compression Force Load Cell
Model |
HMD1005E | |
Comprehensive error |
0.02 |
0.03 |
Output sensitivity mV/V |
2.0±0.25% |
|
Nonlinearity %F.S. |
±0.02 |
±0.03 |
Repeatability %F.S. |
0.02 |
0.02 |
Hysteresis %F.S. |
±0.02 |
±0.03 |
Creep (30min) %F.S |
±0.02 |
±0.03 |
Temp effect on zero %F.S/10°C |
≤0.002 |
≤0.003 |
Temp effect output %F.S/10°C |
≤0.002 |
≤0.003 |
Zero output %FS |
±1 |
±1 |
Input resistance Ω |
400±30 |
|
Output resistance Ω |
350±3 |
|
Insulation resistance MΩ |
≥5000 |
|
Excitation voltage V(DC/AC) |
9~12V |
|
Operation temp. Range °C |
-30~+80 |
|
Overload capacity %F.S. |
150 |
|
Capacity |
1~500kg |
|
Degree of protection |
IP66 |