Solution Basins with CE Certificate and ISO9001

China Solution Basins with CE Certificate and ISO9001, Find details about China Solution Reservoirs, PVC Basin/ PS Basin/ PP Basin from Solution Basins with CE Certificate and ISO9001

Model NO.
25-0051/1025/0052/0051/1100
Volumn
25/50/55/100ml
Package
Bulk Rack
Materi
PS/PP/PVC
Trademark
Biologix
Transport Package
PVC, Nonsterile, 55ml Capacity, Clear, 100 Pieces/
Specification
CE, FDA, ISO
Origin
Jiangsu, Changzhou, China
HS Code
3926909090
Model NO.
25-0051/1025/0052/0051/1100
Volumn
25/50/55/100ml
Package
Bulk Rack
Materi
PS/PP/PVC
Trademark
Biologix
Transport Package
PVC, Nonsterile, 55ml Capacity, Clear, 100 Pieces/
Specification
CE, FDA, ISO
Origin
Jiangsu, Changzhou, China
HS Code
3926909090
Solution Reservoirs

25-0052

Super clear solution reservoir
PVC
Non-sterile
Maximum capacity of 55ml
Disposable
Used with single or multi-channel pipettors

25-0051

Individually wrapped solutions reservoirs
White polystyrene
Sterile
Maximum capacity of 55ml
Disposable
Used with single or multi-channel pipettors
25-1202
Flip-Side 12-Channel Solution Basins
PP, autoclavable
Non-sterile
Disposable
Individual channels are 5ml volume, flip-side 50ml volume
5 assorted colors: Blue, green, red, yellow and clear
Catalog #MaterialPackageColorSterileUnit
25-0052PVCBulkClearNo100 Pieces/pack, 8 Packs/case
25-0051PSIndividualWhiteYes50 Pieces/case
25-1202PPBulkAssorted ColorsNo25 Pieces/bag,4 Bags/case
Solution Basins with CE Certificate and ISO9001Solution Basins with CE Certificate and ISO9001Solution Basins with CE Certificate and ISO9001Solution Basins with CE Certificate and ISO9001
  1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
  1. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.