China Anel500-200 500V/200A Feedback DC Electronic Load, Find details about China DC Feedback Electronic Load, 500V DC Electronic Load from Anel500-200 500V/200A Feedback DC Electronic Load
ANEL series feedback DC electronic load adopts high-frequency PWM rectification and bidirectional DCDC conversion, FPGA digital control, energy feedback to the grid at full power, more energy-saving, green and environmentally friendly compared with conventional DC load; advanced digital control, ultra-high control accuracy, fast response, wide output voltage range, it can achieve full range of load input from 0V to full scale.
Figure 21 Diagram of ANEL series feedback DC electronic load
The feedback DC electronic load realizes the DC load function of automatic energy feedback to the grid. Compared with the conventional load, it is more convenient and safe. The conventional load is energy-consuming, and energy is consumed by resistance heating; the feedback DC electronic load is energy-feeding, and the energy is fed back to the grid, green, environment friendly, reliable, safe, featuring outstanding advantages.
Voltage level | Product model | Rated current (A) | Peak current (A) | Current peak time (S) | Rated power (kW) | Peak power (kW) | Power peak time (S) |
500 V | ANEL500-200 | 200 | 300 | 60 | 60 | 90 | 60 |
General parameters of ANELseries | |||
DC input | Voltage range | 0-full scale | |
Voltage accuracy | 0.1% F.S, resolution: 0.1V | ||
Current accuracy | 0.1% F.S, resolution: 0.1A | ||
Source effect\Load effect | 0.1%F.S | ||
Ripple (Vpp) | 0.2%F.S | ||
Transient recovery time | ≤ 5 ms | ||
Current rise time | ≤ 1 ms | ||
AC output | Voltage/frequency | 3-phase 4-wire +PE, line voltage: 380V±57V, 45~65Hz | |
Power factor | ≥0.99 | ||
Total harmonic content | ≤3% | ||
Feedback function | Energy feedback at full power | ||
Function | Wave editing | Control of voltage/current slope, ladder, cycle control, jump control | |
E-stop | E-stop button | ||
Protection | IGBT overheating, IGBT overcurrent, transformer overheating, output lack phase, bus overvoltage, input overvoltage, input overcurrent | ||
Communication port | RS232/RS485, CAN port | ||
Local operation | Compatible touch and key operation | ||
Working environment | Temp./humidity | 0~40ºC, 10~90%RH (no condensation) | |
Altitude | ≤2000m | ||
Weight and dimension | Weight | 1030 kg | |
Dimension W×H×D(mm) | 1000×2000×1000 | ||
The dimension and weight is that for type of 120kW and below. For other types, contact us for detail. |