Anel500-200 500V/200A Feedback DC Electronic Load

China Anel500-200 500V/200A Feedback DC Electronic Load, Find details about China DC Feedback Electronic Load, 500V DC Electronic Load from Anel500-200 500V/200A Feedback DC Electronic Load

Model NO.
ANEL500-200
After-Sales Service
Provide After-Sales Service
Manufacturer
Yes
Control
Fpga
Working Mode
Cc/CV/Cp
Output Precision
Output Voltage/Current Precision 0.1%F.S
Protection
Otp/Ovp/OPP/SCP/Rvp/Ssp/Oop/Hwp/Swp
Applications
Fuel Cell, Charger, Battery Pack Testing, etc
Trademark
Ainuo
Transport Package
Wooden Case
Specification
1000*2000*1000
Origin
Jinan
Model NO.
ANEL500-200
After-Sales Service
Provide After-Sales Service
Manufacturer
Yes
Control
Fpga
Working Mode
Cc/CV/Cp
Output Precision
Output Voltage/Current Precision 0.1%F.S
Protection
Otp/Ovp/OPP/SCP/Rvp/Ssp/Oop/Hwp/Swp
Applications
Fuel Cell, Charger, Battery Pack Testing, etc
Trademark
Ainuo
Transport Package
Wooden Case
Specification
1000*2000*1000
Origin
Jinan
 
Product Description

 

ANEL series feedback DC electronic load adopts high-frequency PWM rectification and bidirectional DCDC conversion, FPGA digital control, energy feedback to the grid at full power, more energy-saving, green and environmentally friendly compared with conventional DC load; advanced digital control, ultra-high control accuracy, fast response, wide output voltage range, it can achieve full range of load input from 0V to full scale.

Anel500-200 500V/200A Feedback DC Electronic Load

Figure 21 Diagram of ANEL series feedback DC electronic load



The feedback DC electronic load realizes the DC load function of automatic energy feedback to the grid. Compared with the conventional load, it is more convenient and safe. The conventional load is energy-consuming, and energy is consumed by resistance heating; the feedback DC electronic load is energy-feeding, and the energy is fed back to the grid, green, environment friendly, reliable, safe, featuring outstanding advantages.

Detailed Photos
Anel500-200 500V/200A Feedback DC Electronic Load
Two-stage circuit of PWM rectification and bidirectional DCDC, achieving load of automatic energy feedback to the grid, energy saving, green and environment protection.
Mainstream high-frequency PWM rectification control, power factor ≥0.99, THD and injected harmonic current meet the requirements of GB/T14549-93, high-quality energy feedback to the grid.
High-precision output: accuracy of voltage and current: ±0.1% F.S.
Fast dynamic response: response time for 10%-90% sudden applied load and 90%-10% sudden shedding load: ≤5ms
Optimized bidirectional DCDC conversion, wider range of DC input voltage, 0V-full scale DC input.
CC, CV, CP modes.
Multi protection: input over-voltage/under-voltage, lack phase, output over voltage, IGBT overheat, IGBT over current, over temperature protection, short circuit current-limiting protection.
Built-in EMI filter to filter the interference signal caused by the high-frequency switching process.
Communication and remote control: standard CAN, RS232/RS485 port and remote control software of the upper computer.
Efficiency up to 95% under rated conditions.
Large-screen LCD display, compatible with buttons and touch screen, suitable for operation under various harsh operating conditions.
Screen (key) lock: After the power supply is not operated for more than 5 minutes, the keyboard and input of touch screen will automatically be locked.

Applications:
1. Fuel cell test;                          
2. Testing of charger and charging pile

3. Battery pack, battery pack discharge test    
4. Capacitor, super capacitor discharge test

5. Power electronics test                   
6. Energy storage system converter test

7. Replace conventional DC load

Anel500-200 500V/200A Feedback DC Electronic Load
Product Parameters
      
Voltage levelProduct modelRated current
(A)
Peak current
(A)
Current peak time (S)Rated power (kW)Peak power (kW)Power peak time
(S)
500 VANEL500-20020030060609060
 
General parameters of ANELseries
DC inputVoltage range0-full scale
Voltage accuracy0.1% F.S, resolution: 0.1V
Current accuracy0.1% F.S, resolution: 0.1A
Source effect\Load effect0.1%F.S
Ripple (Vpp)0.2%F.S
Transient recovery time 5 ms
Current rise time 1 ms 
AC  output Voltage/frequency3-phase 4-wire +PE, line voltage: 380V±57V, 45~65Hz
Power factor≥0.99
Total harmonic content≤3%
Feedback functionEnergy feedback at full power
FunctionWave editingControl of voltage/current slope, ladder, cycle control, jump control
E-stopE-stop button
ProtectionIGBT overheating, IGBT overcurrent, transformer overheating, output lack phase, bus overvoltage, input overvoltage, input overcurrent
Communication portRS232/RS485, CAN port
Local operationCompatible touch and key operation
Working environmentTemp./humidity0~40ºC, 10~90%RH (no condensation)
Altitude≤2000m
Weight and dimensionWeight1030 kg

Dimension W×H×D(mm)
1000×2000×1000
The dimension  and weight is that for type of 120kW and below. For other types, contact us for detail.
 