China 20HP Commercial Direct Heating Heat Pump Hotel School Hot Water, Find details about China Heat Pump Water Heater, Air to Water Heat Pump from 20HP Commercial Direct Heating Heat Pump Hotel School Hot Water
Circulating type of Domestic Hot Water Heat Pump adopts high efficiency tube-in-shell water heat exchanger and incorporates a built-in water pump for easy installation work. The unit is capable of producing high hot water with a maximum temperature up to 60ºC. Circulating Hot Water Heat Pump can be retrofitted to existing geyser to replace electric water heater, saving more than 2/3 energy.
Instant type of Domestic Hot Water Heat Pump adopts advanced variable flow rate control technology, keeping a constant water temperature in the cold climate and hot climate. Unlike Circulating Models, the outlet water temperature from Instant Models directly reaches the setting temperature. The fast defrosting technology enables the system work well in the low temperature, moist ambient conditions.
Commercial Air Source Hot Water Heat Pump with versatie design, high outlet water temperature, high COP and low noise operation, ideal for fast and stable hot water supply in various applications, like house, hotel, hospital, school, villa, etc.
♦ High working pressure
The copper pipe is of 0.8~1.2 mm thickness.no welding inside. With its extraordinary pressure resistance property, the copper pipe is without any leakage under 5Mpa pressure test.
♦ The internal spiral surface of the copper tube ensures effectiveness of heat exchange and prevents from lubricant accumulation.
♦ Grooved external surface of the copper tube increases also the heat transfer area which is 3.7 times of the smooth surface.
2) High efficiency tube-in-tube heat exchanger for Instant Heating Heat Pumps
♦ Spiral tube used to increase heat transfer area for high efficiency
♦ Specially designed to provide excellent efficiency, reliability, and reduce fouling.
♦ Famous brand rotary compressor for Domestic Heat Pumps
♦ Bitzer, Copeland, Danfoss or Panasonic compressor for Commercial Heat Pumps
1) Famous brand high efficiency compressor
2) High efficiency eco-friendly refrigerant, without ozone depletion
3) Intelligent control: micro processor based digital controller with LCD display
4) Adjustable water temp. setting: 25ºC- 60ºC
5) Water heat exchanger: tube-in- shell for cycle heating models, tube-in-tube for direct heating models
6) Automatic defrosting function included
7) Built-in circulation water pump is optional
8) Anti- legionella function on regular intervals
9) Can be retrofitted to existing geyser and used in conjunction with solar geyser
Options: Hot Water Heat Pump (Domestic & Commercial, Cycle & Direct Heating Type)
Domestic Hot Water Heat Pump (Circulating) | ||||||||
Model | DHW-3.5C | DHW-5C | DHW-7C | DHW-10C | DHW-14C | DHW-18C | ||
HP | 1 | 1.5 | 2 | 3 | 4 | 5 | ||
Power supply | V/Hz/Ph | 220-240/50/1 | 380-415/50/3 | |||||
Heating performance | Heating capacity | kW/h | 3.5 | 5.2 | 7.2 | 9.8 | 14 | 18 |
Power input | kW | 0.74 | 1.05 | 1.48 | 2.00 | 2.97 | 3.83 | |
Running current | A | 3.3 | 4.8 | 6.7 | 9.1 | 13.5 | 6.8 | |
COP | - | 4.75 | 4.95 | 4.85 | 4.91 | 4.72 | 4.70 | |
Hot water production: 15/55°C | L/h | 75 | 112 | 155 | 211 | 301 | 387 | |
Suggested tank connection (capacity range) | Liter | 100-300 | 150-350 | 200-500 | 300-600 | 400-800 | 500-1000 | |
Ambient temp. range | °C | -10~43 | ||||||
Rated/Max.outlet water temp. | °C | 55/60 | ||||||
Rated water flow rate | m³/h | 0.60 | 0.89 | 1.24 | 1.69 | 2.41 | 3.10 | |
Controller | - | Micro processor based digital wire controller with LCD display | ||||||
External cabinet | - | Galvanized steel with powder coating | ||||||
Compressor | Type | - | Rotary | Rotary/Scroll | Scroll | |||
Qty. | Nos. | 1 | ||||||
Refrigerant | - | R22/R407c/R417a | ||||||
Heat exchanger (water side) | - | High efficiency tube-in-shell | ||||||
Billt-in water pump | - | Wilo/Shinhoo | ||||||
Water connection | Inlet&Outlet | inch | 3/4" | 1-1/4" | ||||
Noise level | dB(A) | 52 | 52 | 52 | 55 | 55 | 55 | |
Net dimension | W*D*H | mm | 940*350*550 | 940*350*550 | 1000*300*650 | 1125*455*760 | 1175*430*815 | 900*420*1390 |
Net weight | kg | 38 | 50 | 59 | 65 | 95 | 140 | |
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C. Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Domestic Hot Water Heat Pump (Instant) | ||||||||
Model | DHW-3.5I | DHW-5I | DHW-7I | DHW-10I | DHW-14I | DHW-18I | ||
HP | 1 | 1.5 | 2 | 3 | 4 | 5 | ||
Power supply | V/Hz/Ph | 220-240/50/1 | 380-415/50/3 | |||||
Heating Performance | Heating capacity | kW/h | 3.5 | 5.2 | 7.2 | 9.8 | 14 | 18 |
Power input | kW | 0.80 | 1.18 | 1.63 | 2.24 | 3.18 | 4.12 | |
Running current | A | 3.6 | 5.4 | 7.4 | 10.2 | 14.5 | 7.4 | |
COP | - | 4.39 | 4.41 | 4.42 | 4.38 | 4.40 | 4.37 | |
Hot water production: 15/55°C | L/h | 75 | 112 | 155 | 211 | 301 | 387 | |
Suggested tank connection (capacity range) | Liter | 100-300 | 150-350 | 200-500 | 300-600 | 400-800 | 500-1000 | |
Ambient temp. range | °C | -10~43 | ||||||
Rated/Max.outlet water temp. | °C | 55/60 | ||||||
Rated water flow rate | m³/h | 0.60 | 0.89 | 1.24 | 1.69 | 2.41 | 3.10 | |
Controller | - | Micro processor based digital wire controller with LCD display | ||||||
External cabinet | - | Galvanized steel with powder coating | ||||||
Compressor | Type | - | Rotary | Rotary/Scroll | Scroll | |||
Qty. | Nos. | 1 | ||||||
Refrigerant | - | R22/R407c/R417a | ||||||
Heat exchanger (water side) | - | High efficiency tube-in-tube | ||||||
Billt-in water pump | - | Wilo/Shinhoo | ||||||
Water connection | Inlet&Outlet | inch | 3/4" | 1-1/4" | ||||
Noise level | dB(A) | 52 | 52 | 52 | 55 | 55 | 55 | |
Net dimension | W*D*H | mm | 940*350*550 | 940*350*550 | 1000*300*650 | 1125*455*760 | 1175*430*815 | 900*420*1390 |
Net weight | kg | 38 | 50 | 59 | 65 | 95 | 140 | |
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C. Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Commercial Hot Water Heat Pump (Circulating) | ||||||||||||||
Model | CHW-005C | CHW-006C | CHW-007C | CHW-010C | CHW-012C | CHW-015C | CHW-018C | CHW-020C | CHW-025C | CHW-030C | CHW-040C | CHW-050C | ||
HP | 5 | 6 | 7 | 10 | 12 | 15 | 18 | 20 | 25 | 30 | 40 | 50 | ||
Power supply | V/Hz/Ph | 380-415/50/3 | ||||||||||||
Heating Performance | Heating capacity | kW/h | 18 | 21 | 24.6 | 36.0 | 42 | 49 | 60 | 74 | 90 | 100 | 148 | 180 |
Power input | kW | 4.30 | 4.90 | 5.85 | 8.60 | 9.80 | 11.80 | 14.30 | 17.40 | 21.00 | 23.70 | 35.00 | 42.00 | |
Running current | A | 7.7 | 8.8 | 10.5 | 15.4 | 17.5 | 21.1 | 25.6 | 31.1 | 37.5 | 42.4 | 62.6 | 75.1 | |
COP | - | 4.23 | 4.29 | 4.21 | 4.19 | 4.29 | 4.15 | 4.20 | 4.25 | 4.29 | 4.22 | 4.23 | 4.29 | |
Hot water production: 15/55°C | L/h | 391 | 451 | 529 | 774 | 903 | 1053 | 1290 | 1591 | 1935 | 2150 | 3181 | 3869 | |
Ambient temp. range | °C | -10~43 | ||||||||||||
Rated/Max.outlet water temp. | °C | 55/60 | ||||||||||||
Rated water flow rate | m³/h | 3.13 | 3.61 | 4.23 | 6.19 | 7.22 | 8.43 | 10.32 | 12.73 | 15.48 | 17.20 | 25.45 | 30.95 | |
Rated pressure drop | kPa | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Controller | - | Micro processor based digital wire controller with LCD display | ||||||||||||
External cabinet | - | Heavy gaugle galvanized steel with powder coating | ||||||||||||
Compressor | Type | - | Scroll | |||||||||||
Qty. | Nos. | 1 | 2 | 4 | ||||||||||
Refrigerant | - | R22/R407c/R417a | ||||||||||||
Water heat exchanger | - | High efficiency tube-in-shell | ||||||||||||
Water connection | Inlet&Outlet | inch | 1'' | 1-1/2'' | 2'' | 2-1/2'' | 3'' | |||||||
Noise level | dB(A) | 56 | 56 | 57 | 59 | 59 | 63 | 69 | 69 | 71 | 72 | 73 | 74 | |
Net dimension | W | mm | 740 | 740 | 740 | 1470 | 1470 | 1470 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 |
D | mm | 740 | 740 | 740 | 840 | 840 | 840 | 950 | 950 | 950 | 1100 | 1900 | 1900 | |
H | mm | 835 | 835 | 835 | 950 | 950 | 950 | 2000 | 2000 | 2100 | 2050 | 2000 | 2000 | |
Net weight | kg | 130 | 135 | 140 | 230 | 236 | 253 | 550 | 550 | 600 | 740 | 1075 | 1180 | |
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C. Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
Commercial Hot Water Heat Pump (Instant) | |||||||||||
Model | CHW-005I | CHW-010I | CHW-012I | CHW-015I | CHW-020I | CHW-025I | CHW-030I | CHW-040I | CHW-050I | ||
HP | 5 | 10 | 12 | 15 | 20 | 25 | 30 | 40 | 50 | ||
Power supply | V/Hz/Ph | 380-415/50/3 | |||||||||
Heating Performance | Heating capacity | kW/h | 19 | 37.5 | 45 | 55 | 75 | 90 | 110 | 150 | 180 |
Power input | kW | 4.34 | 8.43 | 10.20 | 12.22 | 17.24 | 19.87 | 24.61 | 33.26 | 40.72 | |
Running current | A | 7.8 | 15.1 | 18.2 | 21.8 | 30.8 | 35.5 | 44.0 | 59.5 | 72.8 | |
COP | - | 4.38 | 4.45 | 4.41 | 4.50 | 4.35 | 4.53 | 4.47 | 4.51 | 4.42 | |
Hot water production: 15/55°C | L/h | 408 | 806 | 967 | 1182 | 1612 | 1935 | 2365 | 3224 | 3869 | |
Ambient temp. range | °C | -10~43 | |||||||||
Rated/Max.outlet water temp. | °C | 55/60 | |||||||||
Rated water flow rate | m³/h | 3.27 | 6.45 | 7.74 | 9.46 | 12.90 | 15.48 | 18.92 | 25.80 | 30.95 | |
Rated pressure drop | kPa | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
Controller | - | Micro processor based digital wire controller with LCD display | |||||||||
External cabinet | - | Heavy gaugle galvanized steel with powder coating | |||||||||
Compressor | Type | - | Scroll | ||||||||
Qty. | Nos. | 1 | 2 | 3 | 4 | ||||||
Refrigerant | - | R22/R407c/R417a | |||||||||
Water heat exchanger | - | High efficiency tube-in-tube | |||||||||
Water connection | Inlet&Outlet | inch | 1-1/4'' | 1-1/2'' | 2'' | 2-1/2'' | 3'' | ||||
Noise level | dB(A) | 56 | 59 | 59 | 63 | 69 | 72 | 72 | 72 | 72 | |
Net dimension | W*D*H | mm | 800*760*975 | 1470*840*950 | 1470*840*950 | 1470*840*950 | 2000*950*2000 | 2000*950*2100 | 2000*1100*2050 | 2000*1900*2000 | 2000*1900*2000 |
Net weight | kg | 130 | 380 | 380 | 500 | 570 | 600 | 1140 | 1200 | 1200 | |
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C. Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information. |
1.Blueway has around 30 years of rich HVAC manufacturing experience.
2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.
3.Over 10000 engineering solutions with great success provided by Blueway.
4.Online technical service is available twenty-four hours a day without break.
5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.
So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
Q: Whether with built-in water pump?
A: Generally, domestic type adopts built-in water pump as standard. Wilo or Shinhoo (Chinese domestic brand) are optional.
Q: How about the package?
A: Export plywood pallet.
Q: Refrigerant type?
A: R22/R407c/R417a.
Q: What's the max. outlet water temperature?
A: For normal type, generally, the max. outlet water temp. is 60ºC. For high temperature, 80ºC for on-off type, 90ºC for inverter type. If you would like to know more details for higher temperature type, please refer to the "High Temperature Heat Pump" series.
Q: Hong long is the production period?
A: Circulating Hot Water Heat Pump mainly depends on the raw material & production plan. Generally, It takes about 15 working days. If for customized type, which may takes about 35 working days.
Q: What's the minumum purchasing quantity?
A: Sample order is workable.
Q: What's the difference of water heat exchanger between circulating and instant type?
A: Water heat exchanger: tube-in- shell for cycle heating models, and tube-in-tube for direct heating models.