20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

China 20HP Commercial Direct Heating Heat Pump Hotel School Hot Water, Find details about China Heat Pump Water Heater, Air to Water Heat Pump from 20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

Model NO.
CHW-020I (20HP)
Controller
Wired Controller
Heating Capacity
75kw
Water Heat Exchanger
High Efficiency Tube-in-Tube
Type
Compact
Trademark
Blueway
Transport Package
Carton+Wooden Pallet for Container Order
Specification
20HP
Origin
Guangdong, China
HS Code
8418612090
Model NO.
CHW-020I (20HP)
Controller
Wired Controller
Heating Capacity
75kw
Water Heat Exchanger
High Efficiency Tube-in-Tube
Type
Compact
Trademark
Blueway
Transport Package
Carton+Wooden Pallet for Container Order
Specification
20HP
Origin
Guangdong, China
HS Code
8418612090

PRODUCTION DESCRIPTION

 

Circulating & Instant Type


Circulating type of Domestic Hot Water Heat Pump adopts high efficiency tube-in-shell water heat exchanger and incorporates a built-in water pump for easy installation work. The unit is capable of producing high hot water with a maximum temperature up to 60ºC. Circulating Hot Water Heat Pump can be retrofitted to existing geyser to replace electric water heater, saving more than 2/3 energy.

Instant type of Domestic Hot Water Heat Pump adopts advanced variable flow rate control technology, keeping a constant water temperature in the cold climate and hot climate. Unlike Circulating Models, the outlet water temperature from Instant Models directly reaches the setting temperature. The fast defrosting technology enables the system work well in the low temperature, moist ambient conditions.

Commercial Air Source Hot Water Heat Pump with versatie design, high outlet water temperature, high COP and low noise operation, ideal for fast and stable hot water supply in various applications, like house, hotel, hospital, school, villa, etc.

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

KEY FEATURES

 
Water Heat Exchanger
 
1) High efficiency tube-in-shell heat exchanger for Circulating Heat Pumps

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

♦ High working pressure

The copper pipe is of 0.8~1.2 mm thickness.no welding inside. With its extraordinary pressure resistance property, the copper pipe is without any leakage under 5Mpa pressure test.

♦ The internal spiral surface of the copper tube ensures effectiveness of heat exchange and prevents from lubricant accumulation.

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water
♦ Grooved external surface of the copper tube increases also the heat transfer area which is 3.7 times of the smooth surface.
 

 

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

2) High efficiency tube-in-tube heat exchanger for Instant Heating Heat Pumps

♦ Spiral tube used to increase heat transfer area for high efficiency

♦ Specially designed to provide excellent efficiency, reliability, and reduce fouling.

Compressor

 

♦ Famous brand rotary compressor for Domestic Heat Pumps

♦ Bitzer, Copeland, Danfoss or Panasonic compressor for Commercial Heat Pumps

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

 

1) Famous brand high efficiency compressor

2) High efficiency eco-friendly refrigerant, without ozone depletion

3) Intelligent control: micro processor based digital controller with LCD display

4) Adjustable water temp. setting: 25ºC- 60ºC

5) Water heat exchanger: tube-in- shell for cycle heating models, tube-in-tube for direct heating models

6) Automatic defrosting function included

7) Built-in circulation water pump is optional

8) Anti- legionella function on regular intervals

9) Can be retrofitted to existing geyser and used in conjunction with solar geyser 
 

TECHNICAL SPECIFICATIONS

Options: Hot Water Heat Pump (Domestic & Commercial, Cycle & Direct Heating Type)

Domestic Hot Water Heat Pump (Circulating)
ModelDHW-3.5CDHW-5CDHW-7CDHW-10CDHW-14CDHW-18C
HP11.52345
Power supplyV/Hz/Ph220-240/50/1380-415/50/3
Heating performanceHeating capacitykW/h3.55.27.29.81418
Power inputkW0.74 1.05 1.48 2.00 2.97 3.83 
Running currentA3.3 4.8 6.7 9.1 13.5 6.8 
COP-4.75 4.95 4.85 4.91 4.72 4.70 
Hot water production: 15/55°CL/h75112155211301387
Suggested tank connection (capacity range)Liter100-300150-350200-500300-600400-800500-1000
Ambient temp. range°C-10~43
Rated/Max.outlet water temp.°C55/60
Rated water flow ratem³/h0.60 0.89 1.24 1.69 2.41 3.10 
Controller-Micro processor based digital wire controller with LCD display
External cabinet-Galvanized steel with powder coating
CompressorType-RotaryRotary/ScrollScroll
Qty.Nos.1
Refrigerant-R22/R407c/R417a
Heat exchanger (water side)-High efficiency tube-in-shell
Billt-in water pump-Wilo/Shinhoo
Water connectionInlet&Outletinch3/4"1-1/4"
Noise leveldB(A)525252555555
Net dimensionW*D*Hmm940*350*550940*350*5501000*300*6501125*455*7601175*430*815900*420*1390
Net weightkg3850596595140
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C.
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Domestic Hot Water Heat Pump (Instant)
ModelDHW-3.5IDHW-5IDHW-7IDHW-10IDHW-14IDHW-18I
HP11.52345
Power supplyV/Hz/Ph220-240/50/1380-415/50/3
Heating PerformanceHeating capacitykW/h3.55.27.29.81418
Power inputkW0.80 1.18 1.63 2.24 3.18 4.12 
Running currentA3.6 5.4 7.4 10.2 14.5 7.4 
COP-4.39 4.41 4.42 4.38 4.40 4.37 
Hot water production: 15/55°CL/h75112155211301387
Suggested tank connection (capacity range)Liter100-300150-350200-500300-600400-800500-1000
Ambient temp. range°C-10~43
Rated/Max.outlet water temp.°C55/60
Rated water flow ratem³/h0.60 0.89 1.24 1.69 2.41 3.10 
Controller-Micro processor based digital wire controller with LCD display
External cabinet-Galvanized steel with powder coating
CompressorType-RotaryRotary/ScrollScroll
Qty.Nos.1
Refrigerant-R22/R407c/R417a
Heat exchanger (water side)-High efficiency tube-in-tube
Billt-in water pump-Wilo/Shinhoo
Water connectionInlet&Outletinch3/4"1-1/4"
Noise leveldB(A)525252555555
Net dimensionW*D*Hmm940*350*550940*350*5501000*300*6501125*455*7601175*430*815900*420*1390
Net weightkg3850596595140
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C.
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Commercial Hot Water Heat Pump (Circulating)
ModelCHW-005CCHW-006CCHW-007CCHW-010CCHW-012CCHW-015CCHW-018CCHW-020CCHW-025CCHW-030CCHW-040CCHW-050C
HP567101215182025304050
Power supplyV/Hz/Ph380-415/50/3
Heating PerformanceHeating capacitykW/h18 21 24.6 36.0 42 49 60 74 90 100 148 180 
Power inputkW4.30 4.90 5.85 8.60 9.80 11.80 14.30 17.40 21.00 23.70 35.00 42.00 
Running currentA7.7 8.8 10.5 15.4 17.5 21.1 25.6 31.1 37.5 42.4 62.6 75.1 
COP-4.23 4.29 4.21 4.19 4.29 4.15 4.20 4.25 4.29 4.22 4.23 4.29 
Hot water production: 15/55°CL/h391 451 529 774 903 1053 1290 1591 1935 2150 3181 3869 
Ambient temp. range°C-10~43
Rated/Max.outlet water temp.°C55/60
Rated water flow ratem³/h3.13 3.61 4.23 6.19 7.22 8.43 10.32 12.73 15.48 17.20 25.45 30.95 
Rated pressure dropkPa505050505050505050505050
Controller-Micro processor based digital wire controller with LCD display
External cabinet-Heavy gaugle galvanized steel with powder coating
CompressorType-Scroll
Qty.Nos.124
Refrigerant-R22/R407c/R417a
Water heat exchanger-High efficiency tube-in-shell
Water connectionInlet&Outletinch1''1-1/2''2''2-1/2''3''
Noise leveldB(A)565657595963696971727374
Net dimensionWmm740740740147014701470200020002000200020002000
Dmm740740740840840840950950950110019001900
Hmm835835835950950950200020002100205020002000
Net weightkg13013514023023625355055060074010751180
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C.
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Commercial Hot Water Heat Pump (Instant)
ModelCHW-005ICHW-010ICHW-012ICHW-015ICHW-020ICHW-025ICHW-030ICHW-040ICHW-050I
HP51012152025304050
Power supplyV/Hz/Ph380-415/50/3
Heating PerformanceHeating capacitykW/h19 37.5 45 55 75 90 110 150 180 
Power inputkW4.34 8.43 10.20 12.22 17.24 19.87 24.61 33.26 40.72 
Running currentA7.8 15.1 18.2 21.8 30.8 35.5 44.0 59.5 72.8 
COP-4.38 4.45 4.41 4.50 4.35 4.53 4.47 4.51 4.42 
Hot water production: 15/55°CL/h408 806 967 1182 1612 1935 2365 3224 3869 
Ambient temp. range°C-10~43
Rated/Max.outlet water temp.°C55/60
Rated water flow ratem³/h3.27 6.45 7.74 9.46 12.90 15.48 18.92 25.80 30.95 
Rated pressure dropkPa505050505050505050
Controller-Micro processor based digital wire controller with LCD display
External cabinet-Heavy gaugle galvanized steel with powder coating
CompressorType-Scroll
Qty.Nos.1234
Refrigerant-R22/R407c/R417a
Water heat exchanger-High efficiency tube-in-tube
Water connectionInlet&Outletinch1-1/4''1-1/2''2''2-1/2''3''
Noise leveldB(A)565959636972727272
Net dimensionW*D*Hmm800*760*9751470*840*9501470*840*9501470*840*9502000*950*20002000*950*21002000*1100*20502000*1900*20002000*1900*2000
Net weightkg130380380500570600114012001200
The above data is based on the following testing condition: ambient temp.(DB/WB) = 20°C/15°C, inlet/outlet water temp. = 15°C/55°C.
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 

MANUFACTURING & SHIPMENT

 

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

 

ADVANTAGES & MARKET OVERVIEW

 

1.Blueway has around 30 years of rich HVAC manufacturing experience.

2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.

3.Over 10000 engineering solutions with great success provided by Blueway.

4.Online technical service is available twenty-four hours a day without break.

5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
 

With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.

 

So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
 

20HP Commercial Direct Heating Heat Pump Hotel School Hot Water

 

FAQ

Q: Whether with built-in water pump?

A: Generally, domestic type adopts built-in water pump as standard. Wilo or Shinhoo (Chinese domestic brand) are optional.

 

Q: How about the package?

A: Export plywood pallet.

 

Q: Refrigerant type?

A: R22/R407c/R417a.

 

Q: What's the max. outlet water temperature?

A: For normal type, generally, the max. outlet water temp. is 60ºC. For high temperature, 80ºC for on-off type, 90ºC for inverter type. If you would like to know more details for higher temperature type, please refer to the "High Temperature Heat Pump" series.

 

Q: Hong long is the production period?

A: Circulating Hot Water Heat Pump mainly depends on the raw material & production plan. Generally, It takes about 15 working days. If for customized type, which may takes about 35 working days.

 

Q: What's the minumum purchasing quantity?

A: Sample order is workable.

 

Q: What's the difference of water heat exchanger between circulating and instant type?

A: Water heat exchanger: tube-in- shell for cycle heating models, and tube-in-tube for direct heating models.