Non Contact Ultrasonic Module Distance Measuring Transducer Sensor

China Non Contact Ultrasonic Module Distance Measuring Transducer Sensor, Find details about China Ultrasonic Level Sensor, Industrial Ultrasonic Level Sensor from Non Contact Ultrasonic Module Distance Measuring Transducer Sensor

Model NO.
UM500-30GM-AI
Detection mode
On the Radio
IP Rating
IP68
Certification
CE
Customized
Customized
Frequency
100 kHz
Protection Level
IP67
Sensing Distance
180-2500mm
Housing Material
Brass Nickel-Plated
with Circuit
Yes
Weight
70g
Output Type
Analogue Output 4,20mA
No-Load Supply Current
<20mA
Trademark
PIEZOHANNAS
Transport Package
Carton
Specification
based on size
Origin
China
HS Code
8479899990
Model NO.
UM500-30GM-AI
Detection mode
On the Radio
IP Rating
IP68
Certification
CE
Customized
Customized
Frequency
100 kHz
Protection Level
IP67
Sensing Distance
180-2500mm
Housing Material
Brass Nickel-Plated
with Circuit
Yes
Weight
70g
Output Type
Analogue Output 4,20mA
No-Load Supply Current
<20mA
Trademark
PIEZOHANNAS
Transport Package
Carton
Specification
based on size
Origin
China
HS Code
8479899990
Non Contact Ultrasonic Module Distance Measuring Transducer Sensor 

Non Contact Ultrasonic Module Distance Measuring Transducer Sensor


Technical parameters:
 
 
DUltrasonic sensor  
Technical data 
General Specifications 
Sensing distance      180…2500mm
Adjustment range 180…2500mm
Unusable area 0…18mm
Standard target plate 100mm×100mm
Transducer frequency About 100 kHz
Response delay About 125ms
Indicators/Operating means  
LED yellow solid: object in evaluation range
flash: program function
LED redflashing: program function
Electrical specifications 
Operating voltage UB10…30VDC ripple10%ss
No-load supply current≤20mA
Output 
Output type1 analogue output 4…20mA
Resolution 
Deviation of the characteristic
curve
±1% of full-scale value
Repeat accuracy±0.1% of full-scale value
Load impedance>1k Ohm
Maximum switching current200 mA
Temperature influence±1.5% of full-scale value
Ambient conditions 
Ambient temperature-25…70ºC
Storage temperature-40…85ºC
Mechanical specifications 
Protection gradeIP67
ConnectionConnector M12,4-PIN
Material  
  HousingBrass nickel-plated
 Transducer epoxy resin/hollow glass sphere
mixture; Polyurethane foam
Weight160g
Compliance with standards and Directives
Standard conformityEN 60947-5-2:2007


                         

Image:

Non Contact Ultrasonic Module Distance Measuring Transducer Sensor


Non Contact Ultrasonic Module Distance Measuring Transducer Sensor

 

Non Contact Ultrasonic Module Distance Measuring Transducer SensorNon Contact Ultrasonic Module Distance Measuring Transducer SensorNon Contact Ultrasonic Module Distance Measuring Transducer Sensor

Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -UB, A2 with +UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.

TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - UB
- Position object at upper evaluation limit                                                
- TEACH-IN upper limit A2 with + UB

TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit                                              
- TEACH-IN lower limit A2 with + UB                                   
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - UB                                                                   
 
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp    
                                                   
LED Displays
Displays in dependence on operating modeRed LEDYellow LED
TEACH-IN evaluation limit
Object detected
No object detected
Object uncertain (TEACH-IN invalid)

off
flashes
on

flashes
off
off
Normal mode (evaluation range)offon
Faultonprevious state