Resuscitaire Baby Infant Radiant Warmer with LED Phototherapy Unit

China Resuscitaire Baby Infant Radiant Warmer with LED Phototherapy Unit, Find details about China Infant Warmer, Infant Radiant Warmer from Resuscitaire Baby Infant Radiant Warmer with LED Phototherapy Unit

Model NO.
IRW-100T
Applications
Nicu,Operating Room
Phototherapy Unit
Yes,LED
Modes
Pre-Warm, Manual or Automatic
X-ray Cassette
Yes
Tilt Angle of Bed
Adjustable
Heater Head
Adjustable
LED Observation Light
Brightness Adjustable
Low Pressure Aspirator
Yes
Trademark
Perlong
Transport Package
Carton
Specification
with trolley
Origin
China
HS Code
90189090
Model NO.
IRW-100T
Applications
Nicu,Operating Room
Phototherapy Unit
Yes,LED
Modes
Pre-Warm, Manual or Automatic
X-ray Cassette
Yes
Tilt Angle of Bed
Adjustable
Heater Head
Adjustable
LED Observation Light
Brightness Adjustable
Low Pressure Aspirator
Yes
Trademark
Perlong
Transport Package
Carton
Specification
with trolley
Origin
China
HS Code
90189090
Resuscitaire Baby Infant Radiant Warmer With LED Phototherapy Unit

Features

Microprocessor based servo controlled temperature system
The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic
APGAR timer to record therapy time
Audible and visual Alarm functions :
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
LED observation light adjustable,brightness adjustable
Heater head can be adjusted ±9 0°horizontally
Convenient X-ray cassette under infant bed
Tilt angle of infant bed is adjustable
Four Transparent protector folded with 2 infusion seals
Integrated low pressure aspirator
LED phototherapy unit
PVC resuscitator
With RS-232 connector,2 trays and 2 drawers

Specifications

Power supply AC110/220V 60/50Hz
Power input 1100VA
Environment temperature 18ºC~30ºC
Operating Environment relative humidity 30%~75%
conditions Atmospheric Pressure 700~1060hpa
Environment air velocity of flow <0.3m/s
Skin Temperature control range 32ºC~3 8ºC
Skin temperature control accuracy ≤0.5ºC
Skin temperature sensor accuracy ±0.3ºC
Mattress temperature uniformity <2ºC
Infant Bed tilt angle ±10°
LED observation light 3W
Warm-up time(from 25ºC) <30min
Heater head horizontal ±90°
Distance from heater to mattress 80cm
Mattress size 67cmX54cm
Timer range 0~99h59min
LED phototherapy light 36cm 620-2800μw/cm2
LED phototherapy light 50cm 400-1620μw/cm2
Low pressure aspirator:
Max vacuum adjustable ≥-25kpa(-188mmHg)
Storage bottle 1000mL