Resuscitaire Infant Radiant Warmer with LED Photherapy Unit and Cassete

China Resuscitaire Infant Radiant Warmer with LED Photherapy Unit and Cassete, Find details about China Infant Warmer, Infant Radiant Warmer from Resuscitaire Infant Radiant Warmer with LED Photherapy Unit and Cassete

Model NO.
IRW-100L
Applications
Nicu,Operating Room
Phototherapy Unit
Yes, LED
Modes
Pre-Warm, Manual or Automatic
Oxygen Cylinder
2PCS*6L
X-ray Cassette
Yes
Tilt Angle of Bed
Electric Inclination
Heater Head
Adjustable
LED Observation Light
Brightness Adjustable
Low Pressure Aspirator
Yes
Trademark
Perlong
Transport Package
Carton
Specification
with trolley
Origin
China
HS Code
90189090
Model NO.
IRW-100L
Applications
Nicu,Operating Room
Phototherapy Unit
Yes, LED
Modes
Pre-Warm, Manual or Automatic
Oxygen Cylinder
2PCS*6L
X-ray Cassette
Yes
Tilt Angle of Bed
Electric Inclination
Heater Head
Adjustable
LED Observation Light
Brightness Adjustable
Low Pressure Aspirator
Yes
Trademark
Perlong
Transport Package
Carton
Specification
with trolley
Origin
China
HS Code
90189090
Resuscitaire Infant Radiant Warmer With LED Photherapy Unit and Cassete

Features

Microprocessor based servo controlled temperature system
Three modes: pre-warm, manual or automatic
Set temperature and skin temperature display separately
Special design inclined heater head is more convenience for X rays
Carbon steel heater for more effectivity
Audible and visual Alarm functions :
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
APGAR timer to record therapy time
Convenient X-ray cassette under infant bed
Electric inclination of infant bed
LED observation light adjustable,brightness adjustable
Four Transparent protector folded with 2 infusion seals
LED phototherapy unit,Oxygen supply system
Bigger infant bed
Built in low pressure aspirator
With RS-232 connector,2 trays and 2 drawers

Specifications

Power supply AC110/220V 60/50Hz
Power input 1100VA
Environment temperature 18ºC~30ºC
Operating Environment relative humidity 30%~75%
conditions Atmospheric Pressure 700~1060hpa
Environment air velocity of flow<0.3m/s
Skin Temperature control range 32ºC~38ºC
Skin temperature control accuracy ≤0.5ºC
Skin temperature sensor accuracy ±0.3ºC
Mattress temperature uniformity <2ºC
Infant Bed tilt angle ±12°
Warm-up time(from 25ºC) <30min
Heater head horizontal ±90°
LED observation light 3W
Low pressure aspirator:
Max vacuum adjustable ≥-25kpa(-188mmHg)
Storage bottle 1000mL
Oxygen cylinder 6LX2
Oxygen flow meter 0-10L/min