Single Phase DC SSR 25A Solid State Relay DC to DC 400V

China Single Phase DC SSR 25A Solid State Relay DC to DC 400V, Find details about China Solid State Relay, Thermal Overload Relay from Single Phase DC SSR 25A Solid State Relay DC to DC 400V

Model NO.
SSR-40DA
Protective Characteristics
Open Relay
Action Principle
Electronic Type
Size
Miniature
Type
Electric Parameter Relay
Contact Load
High Power
Operational Current
10 to 40 AMPS
Operational Voltage
240V or 440V
Dielectric Strength
1500VAC
Control Current
6-35mA
Trademark
Chnanma or as customer request
Transport Package
20PCS in One Box
Specification
CE
Origin
Zhejiang China (Mainland)
HS Code
8536410000
Model NO.
SSR-40DA
Protective Characteristics
Open Relay
Action Principle
Electronic Type
Size
Miniature
Type
Electric Parameter Relay
Contact Load
High Power
Operational Current
10 to 40 AMPS
Operational Voltage
240V or 440V
Dielectric Strength
1500VAC
Control Current
6-35mA
Trademark
Chnanma or as customer request
Transport Package
20PCS in One Box
Specification
CE
Origin
Zhejiang China (Mainland)
HS Code
8536410000
Product Description

solid state relay(SSR) is an electronic switch, which contains no moving parts. Its load current is conducted by one or more semiconductors. The types of SSR are photo-coupled SSR, transformer-coupled SSR, and hybrid SSR.
Solid state relays are widely used in testing instruments, displays, power plant, household appliances and automobiles etc.

Specification
 

Model
HHG1-1/032F-22 2A (SSR-DA)
HHG1-1/032F-38 2A (SSR-DA)
HHG1-0/032F-20 2A (SSR-DD)
Control Voltage032:3-32VDC
Control Current6-35mA
Make-on Voltage3VDC
Break-off Voltage1VDC
Reverse Voltage32VDC
Load VoltageAC:22:30-240VAC,38:40-440VAC
DC:20:12-200VDC
Load Current2A
Instant VoltageAC:22:600VAC;38:900VAC
DC:20:220VDC
Voltage DropAC:<1.6VAC,DC:<1.2VDC
On-off TimeAC:≤10mS,DC:≤5mS
Leakage Current AC:≤10mA, DC:≤5mA
Dielectric Strength≥1500VAC
Insulation Resistance500MΩ,500VDC
Ambient Temperatureminus30 to 80ºC
Indicate Methods/

. Description of solid state relay

Control Voltage
90-250VAC
Control Current5-30mA
Turn-on Voltage90VAC
Turn-off Voltage10VAC
Load Voltage22:30-240VAC,38:40-440VAC
Load Current10A,15A,20A,25A,30A,40A,60A,80A
Transient Voltage22:600VAC,38:900VAC
On-state Voltage Drop<1.6VAC
ON-OFF Time≤10mS
Off-state Leakage Current≤10mA
Dielectrics Voltage-resistance≥2500VAC
Insulation Resistance500MΩ 500VDC testing
Ambient temperature-30~80?
Dimensions63L*45W*26H
Indicated MethodsLED
InstallationScrew fixing