Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set

China Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set, Find details about China Tan Delta Tester, Tan Delta Meter from Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set

Model NO.
GDGY
Environment Temperature
0-50°c
Trademark
Gold
Transport Package
Wooden Case
Specification
53*42*51CM
Origin
Chongqing
HS Code
9031809090
Model NO.
GDGY
Environment Temperature
0-50°c
Trademark
Gold
Transport Package
Wooden Case
Specification
53*42*51CM
Origin
Chongqing
HS Code
9031809090
High Voltage Power Equipment Transformer Tan Delta and Power Factor Tester


Introduction
GDGY Automatic Transformer Power Factor Tester, Transformer Tan Delta Tester is a high-precision instrument, which can be applied to measure electrical loss tangent and capacitance of all kinds of high voltage electrical equipment in power plants, substations, laboratory, etc.

 

2. Tan delta meter Specifications

Accuracy:                       Cx       ±(reading×1%+1pF)

                                      PF       ±(reading×1%+0.00040)

Interference Ratio:           Interference current is no more than 2 times of the test current

PF Range:                       No limit, Resolution 0.001%, C/L/R specimen test

Input current range:         10μA~1A

Internal HV:                   0.5~10kV / 200mA (max)

HV Adjust:                     Rise or fall smoothly

HV Accuracy:                ±(reading×1%+10V) Resolving 1V

Frequency select:            60Hz single point, locked 55Hz/65Hz double point, locked

Test Time:                     40S typical

Power Supply:                180V~270V 50Hz/60Hz auto

Operating Temperature:  0ºC~60ºC

storage Temperature:    -20ºC~60ºC

Humidity:                      <90%

 

3.tan delta meter

Tan Delta (TD) - also referred to as Dissipation Factor or sometime even Power Factor - is an excellent diagnostic test that provides an indication as to the quality of the dielectric insulation used in electrical apparatus. By analyzing the dielectric losses in theinsulation, the GDGS Series of Tan Delta test instruments provide the testing engineer with a versatile high voltage diagnostic system that is suitable for testing MV cable such as XLPE, EPR, PE and PILC. In addition, other electrical apparatus such as capacitors, transformers and large rotating machines can also be diagnosed

 

Item show
Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set


Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set




 




About Us
Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set

Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd was founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer TesterCircuit Breaker AnalyzerCT PT AnalyzerHipot Tester , Relay Tester and so on for more than 10 years.
After several years' development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;
We have developed sales channels in many countries such as UAE, Saudi Arabia, Iran, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.
And we have gained strong advantage and high reputation in international market.



Our workshop
Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set



Certificates
Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set



Customer visit
Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set



International exhibitions
Dielectric Loss Tester Tan Delta Meter Transformer Capacitance Dissipation Test Set