IEC 60754-1 Cable Corrosion Test Appatatus Introduction:The equipment is designed and produced according to GB/T 17650 and IEC60754.The equipment processes the cable material through the prius pipeline furnace, and determines the acidity of the gas generated in the combustion process of the cable material by measuring the PH value and conductivity of the released gas, including the gas volume, PH concentration, electrical conductivity, etc
Reference Standards:- IEC 60754-1 Ed. 2.0 b:1994: Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas
- IEC 60754-2 Ed. 1.0 b:1991: Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity.
- KS C IEC 60754-1: Tests on gases evolved during combustion of electric cables - Part 1: Measurement of the amount of halogen acid gas.
- KS C IEC 60754-2: Tests on gases evolved during combustion of electric cables - Part 2: Corrosiveness test by generating combustion gases.
- KWS 409 : Wire of Fire Resistance (Fire-Resistence) - 5.12 Causticity for Combustion gas.
Features:1. Optimized structural design, reasonable layout, convenient operation, beautiful and generous
2. The control box is equipped with large space drawer for placing relevant accessories of the test
3. Tubular furnace is equipped with adjustable electric heating system with effective length of 500-600mm and inner diameter of 40-60mm
4. Equipped with thermocouple imported from America
5. Equipped with Japanese imported meters to accurately control gas flow
6. Equipped with magnetic PH value and conductivity detector, with electronic display and electrode
7. Prius tube: users can easily insert samples into the prius furnace tube to protect the tube from damage
8. Combustion ship moving system: the motor moves the combustion ship device automatically, and the samples can be moved in and out automatically.Make experiments smarter
9. Mode switching: mode switching switch
10. Temperature alarm controller: control the temperature in the furnace to prevent overheating
11. Lei magnetic permanent magnet agitator: agitator mixing combustion gas in distilled water
Lei magnetic conductometer: instrument for measuring the conductivity of combustion gases
Specifications:- Tube Furnace: For heating section of furnace, its length is 500mm and inner diameter is 40mm. It also contains electrically controllable heating system(Temperature Controller).
- Tube (Pyrex): Fire resistant tube is used in the furnace to protect tube against corrosive gases. The tube is made in silicon dioxide fire-proofing agent. Inner diameter of silica tube is 38mm and the length of tube is 150mm from the entrance of furnace and tube is protruded in a distance of 100mm from the exit.
- Combustion Boat: 98mm(Length)*15mm(Width)*12mm(Depth); Each boat is used only three times before combustion or recycling. (It shall be cleaned after it is used three times.)
- Gas Washing Bottle: Height of liquid in the end of tube shall be 100 ~ 120mm in each bottle.
- Air Supply System: Gas used for combustion shall be air and flow rate of air injected into the tube shall be adjusted according to the actual inner cross section of tube. The speed of air flowing across the sample shall be 378ml/min ±10%.
6 | Size | 1,220 mm (W) × 450 mm (D) × 560 mm (H) |
7 | Furnace | 500 mm (wide), 300 mm (Dia'), 38 mm (Inner Dia') |
8 | Quartz glass tube | 700 mm (wide), 37 mm (Inner Dia') |
9 | Power supply | 220 V AC, 60 Hz, 10 A |
10 | Weight | 60 kg |
11 | Utilities | Air Compressor |
12 | Item Name | IEC 60754-1, 2 Electric Cables Halogen Acid Gas Release Tester, Cable Corrosion Tester |
Product Show:Our Service:Presell Service:After-sale Service: