Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K

China Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K, Find details about China Pressure Sensor, Transducer from Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K

Model NO.
PC112K
Thread Type
No
Wiring Type
Four-Wire
Measuring Medium
Liquid, Gas, Oil, Water
IP Rating
IP65
Certification
RoHS, CE, ISO
Customized
Customized
Pressure Range
-100kpa~0~10kpa...100MPa
Pressure Reference
Gauge, Absolute, Sealed Gauge
Excitation
1.5mA, 10V
Zero Output
±1mv, ±2mv
Non-Linearity
0.25%Fs
Electrical Connection
Gold-Plated Kovar Pin or Silicon Soft Wire
Operating Temp.
-40ºC~125ºC
Diaphragm Material
316L
Housing Material
316L
Oil Filling
Silicon Oil
Trademark
WTsensor
Transport Package
Standard Export Packing with Carton
Origin
China
Model NO.
PC112K
Thread Type
No
Wiring Type
Four-Wire
Measuring Medium
Liquid, Gas, Oil, Water
IP Rating
IP65
Certification
RoHS, CE, ISO
Customized
Customized
Pressure Range
-100kpa~0~10kpa...100MPa
Pressure Reference
Gauge, Absolute, Sealed Gauge
Excitation
1.5mA, 10V
Zero Output
±1mv, ±2mv
Non-Linearity
0.25%Fs
Electrical Connection
Gold-Plated Kovar Pin or Silicon Soft Wire
Operating Temp.
-40ºC~125ºC
Diaphragm Material
316L
Housing Material
316L
Oil Filling
Silicon Oil
Trademark
WTsensor
Transport Package
Standard Export Packing with Carton
Origin
China

PC112K Flush Diaphragm Pressure Sensor with Clamp


Product overview

PC112K pressure sensor adopts a single time silicon oil filling technology. The perceived pressure is transmitted to the pressure chip through the silicone oil to generate an electrical signal, and the compensation circuit corrects the pressure signal to a linear pressure signal. The clamp face diaphragm is exposed to direct pressure, which can prevent scaling, unsanitary and viscous pressure blockage. It is especially suitable for viscous fluid pressure and liquid level measurement in the medical and food industries. It is widely used in food, pharmaceutical, winemaking and other sanitary industries.

The company can customize products for customers, to make products of special structure and size. We have mature batch production lines, which can ensure production tasks be finished perfectly.

Features

Flush diaphragm pressure sensor with clamp structure
Imported highly reliable pressure die
A single time silicon oil isolated filling technology
Compensation board filled with glue for protection against moisture
All stainless steel housing material
High accuracy, high reliability
Strong anti-interference, good long-term stability
18 months warranty period

Applications

Medical, food industry
Environmental protection, chemical, coating
Polyurethane equipment
Industry standards supporting
 
Electrical performance parameters
 
Pressure range-100kPa~0~10kPa…100MPa
Pressure referenceGauge pressure | Absolute pressure | Sealed gauge pressure
Excitation1.5mA recommended for constant current
10V recommended for constant voltage
Input impedanceConstant current: 2kΩ~5kΩ
Constant voltage: 3kΩ~18kΩ
Electrical connectionGold-plated KOVAR pin or silicon soft wire
Compensation temp.Constant current: ≤70kPa 0ºC~60ºC; other ranges -10ºC~70ºC
Constant voltage: -20ºC~85ºC
Operating temp.-40ºC~125ºC
Storage temp.-40ºC~125ºC
Insulation resistance≥200MΩ/250VDC 
Response time≤1ms (up to 90%FS)
Measured mediumAll the liquids and gases compatible with 316L.
Mechanical vibration20g (20~5000HZ)
Shock100g (10ms)
Service life10×106 (cycles)
Structural performance parameters
 
Diaphragm material316L
Housing material316L
Oil fillingSilicon oil
Sealing ringNBR or fluorine rubber
 
Basic parameters
 
ItemConditionMinNominalMaxUnitNote
Nonlinearity -0.3±0.20.3%FSNote(1)
Hysteresis -0.05±0.030.05%FS 
Repeatability -0.05±0.030.05%FS 
Zero output -2±12mV 
Full scale span output1.5mA, 10kPa
1.5mA, other ranges
10V, 10kPa
10V, other ranges
30
60
60
98

90

100

150

102
mV 
Zero temp. coefficient10kPa
other ranges
-2
-1.5
±1.5
±0.75
2
1.5
%FSNote(2)
Span temp. coefficient -1.5±0.751.5%FSNote(2)
Thermal hysteresis -0.075±0.050.075%FSNote(3)
Long term stability -0.3±0.20.3%FS/Year 

Note:
(1) Calculate according to BFSL least square method.
(2) In the compensation temperature range, refer to 30 ºC for 0 ºC ~ 60 and -10 ºC ~ 70 ºC, and refer to 32.5 ºC for -20 ºC ~ 85 ºC.
(3) After passing high and low temperature, return to the reference temperature.

 
Structure and dimensions
 

In mm
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K

Pressure range selection
 
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K
How to order
 
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K



Example: PC112K-35kGI1K1H1T3
Refer to product model PC112K, with pressure range 35kPa, gauge pressure, 1.5mA constant current excitation, 1.5" clamp, 3 pieces cooling elements, and rear thread M25×1.

Ordering tips:
1 Pressure range can be selected higher or lower than actual conditions but should be within ±30%FS.
2 Pressure reference consists of gauge pressure, absolute pressure and sealed gauge pressure.

1. Gauge pressure is based on the current atmospheric pressure. Generally, it refers to the measurement of pressure which is greater than the current atmospheric pressure. Negative pressure is a special case of gauge pressure. It refers that there is such working condition that the pressure of work site is lower than the current atmospheric pressure.
2. Absolute pressure is based on vacuum.
3. As for sealed gauge pressure, PC10 uses absolute pressure die for gauge pressure product based on the atmospheric pressure of production site. For pressure range above 6MPa, gauge pressure cannot be selected, but only sealed gauge pressure. 3 Confirm the maximum overload of the applied system, which should be less than the overload protection limit of the sensor, otherwise it will affect the product life or even damage the product.
4 The commonly used compensation of the product is 1.5mA constant current compensation. Suggest selecting the option with priority.
5 The material and process for manufacturing negative pressure sensors are different from those of positive pressure sensors. So gauge pressure sensors cannot be used as substitute of negative pressure sensors.
6 For special requirements on performance parameters and functions of the product, please contact us.

About Us:
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K

Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K

Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K
Certifications:
Flush Diaphragm Pressure Sensor with Clamp Film Pressure Transducer PC112K




FAQ:
1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on pressure sensor for 33 years.
2.    Q: What international certificates do you have?
        A: ISO9001, CE, RoHS Certificated.
3.    Q: What is your production capacity?
        A: We produced 1500000 pieces pressure sensor in year 2017.
4.    Q: What is the lead time of your product?
        A: Stocks are available for some products. The typical lead time is 8~14 working days for product without customization. 
       Note: lead time may vary base on different products. Please contact us for detailed lead time. 
5.    Q: What is the warranty of your products?
       A: Our warranty time is 18 months after shipment.
6.    Q: Do you provide customized products?
       A: Yes, we can laser mark your logo, model and product information according to your requirement. We provide OEM and ODM service.