Portable 5000A Current Transformer Test Bench

China Portable 5000A Current Transformer Test Bench, Find details about China Current Transformer Test Bench, Transformer Test Bench from Portable 5000A Current Transformer Test Bench

Model NO.
GF106T
Keyword
Current Transformer Test Bench
Model
Portable PT Analyzer
GF106t
Instrument Transformer Test Bench
Accuracy
0.2%
Large Current Output
0-1000A
Overall Dimension (L x W x H) (mm)
400mm X 250mm X 250mm
Weight (Kg)
22
Voltage
0-2500V
Trademark
GFUVE
Transport Package
Standard Export Wooden Box
Specification
400 x 250 x 250 
Origin
Beijing, China
Model NO.
GF106T
Keyword
Current Transformer Test Bench
Model
Portable PT Analyzer
GF106t
Instrument Transformer Test Bench
Accuracy
0.2%
Large Current Output
0-1000A
Overall Dimension (L x W x H) (mm)
400mm X 250mm X 250mm
Weight (Kg)
22
Voltage
0-2500V
Trademark
GFUVE
Transport Package
Standard Export Wooden Box
Specification
400 x 250 x 250 
Origin
Beijing, China
GF106T Portable 5000A current transformer test bench


It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

Electrical Current Potential Transformer Test Bench Price With Test Report Printer Kv Tester , Find Complete Details about Electrical Current Potential Transformer Test Bench Price With Test Report Printer Kv Tester,Kv Tester,Electrical Test Bench Price,Current Potential Transformer Test Bench With Test Report Printer from Testing Equipment Supplier.
Testing of current transformer includes: insulation resistance, polarity, burden, magnetization curve, turns ratio and primary injection test
Portable 5000A Current Transformer Test Bench



Main functions
I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve1. Excitation characteristic test
2. Transformation ratio test2. Transformation ratio test
3. Polarity3. Polarity 
4. 5% and 10% error curve4. Withstand test of power frequency alternating current
5. Current Injecting5. Degauss
6. Degauss6. Calculation of knee point value
7. Withstand test of power frequency alternating   current7. Actual secondary load test
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test
10. Resistance test
Parameters
Electrical parameters
Accuracy0.2%, 0.5%
Power supplyAC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output0-2500Vrms, 
Excitation current output0-5Arms (20A peak-value)
Large current output0-1000A
Electrical parameters - continued
Accuracy≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurementRange0.1-300Ω
Accuracy≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurementRange5VA-1000VA
Accuracy≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurementAccuracy±4min
Resolution0.01min
CT ratio error measurementRange≤25000A/5A(5000A/1A)
Accuracy≤0.5%
PT ratio error measurementRange1-500KV
Accuracy≤0.5%
Standards
Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standardsGB 4793.1-2007
EMCEMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm)400 x 250 x 250 
Weight (kg)  ≤22
Environmental conditions
Relative humidity   90RH%
Operating temperature-10°C to +40°C
Altitude≤1000m

Photo