China GF106t Industrial Electrical Measuring Instruments Transformer Test Equipment, Find details about China Instruments Transformer Test Equipment, Transformer Test Equipment from GF106t Industrial Electrical Measuring Instruments Transformer Test Equipment
Items | Parameter | |
Power supply | AC220V±10% , 50/60Hz | |
Standby time with battery | >5 Hours | |
Equipment output | 0~150Vrms,5Arms(15Apeak ) | |
Voltage measurement accuracy | ±0.1% | |
Burden measurement | range | 0~50 |
accuracy | 0.2% | |
Admittance | range | 0~60mS |
accuracy | 0.2% | |
Two times the actual Load measurement | range | 0~300VA |
accuracy | 1%±0.1VA | |
Phase error measurement | accuracy | ±3min |
resolution | 0.3min | |
CT phase ratio error measurement | range | 5:1~15000:1 |
accuracy | 0.05% | |
PT phase ratio error measurement | range | 5:1~15000:1 |
accuracy | ±0.05% | |
Work environment | Temperature:-10 ~ 40 , humidity:≤ 85% or altitude ≤1000 m | |
Size | 380 mm x 180 mm x 240 mm(L×W×H), | |
Weight | 8kg |