Hm405 Hot Sales Current Transformer Test Set in English

China Hm405 Hot Sales Current Transformer Test Set in English, Find details about China Current Transformer Testing Equipment, Current Transformer Test Set from Hm405 Hot Sales Current Transformer Test Set in English

Model NO.
HM405
Maximum Knee Voltage Measurement
45kv
Output
0.1~125V (AC)
Current Output
0.001-5A(RMS)
Product Name
Current Transformer Testing Equipment
Power Supply
AC220V±10%,50Hz/60Hz±10%
Power Output
300va
Current Measurement: 
0~10A
Voltage Measurement
0~200 V
Turns Ratio Measurement
Turns Ratio Measurement:
Trademark
GDHM
Transport Package
Wooden Box with Foam Inside
Specification
485mm*356mm*183mm
Origin
Hubei, China(Mainland)
Model NO.
HM405
Maximum Knee Voltage Measurement
45kv
Output
0.1~125V (AC)
Current Output
0.001-5A(RMS)
Product Name
Current Transformer Testing Equipment
Power Supply
AC220V±10%,50Hz/60Hz±10%
Power Output
300va
Current Measurement: 
0~10A
Voltage Measurement
0~200 V
Turns Ratio Measurement
Turns Ratio Measurement:
Trademark
GDHM
Transport Package
Wooden Box with Foam Inside
Specification
485mm*356mm*183mm
Origin
Hubei, China(Mainland)

Hm405 Hot Sales Current Transformer Test Set in English

Summary:

CT PT analyzer is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. The tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

 

Applications:

Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test

Hm405 Hot Sales Current Transformer Test Set in English

 

Features:

1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.

 

Technical parameter

1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~125V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement; 45kv
7 Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range :1~30000,
1~1000 error<0.05%
1000~2000 error<0.1%
2000~30000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.1%RDG+0.01%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
14 PT Secondary burden:
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 Saved data groups:>1000groups
16 Work condition: Temperature:-10ºC~50ºC, moist:≤90%
17 Size: 485mm×356mm×183mm
18 Weight: <15Kg



 

Accessaries

Sr noNameQuantityDescription
 1Host1 
 23M mask cable2Test cable for power out and CT secondary connection
 310M mask cable1Test cable for CT primary connection
 4Grounding cable1 
 5Big test pliers2One red and one black
 6Test gasket4Two red and two black
 7Test pin4Two red and two black
 8Test pliers12Three red and nine black
 9Short connection cable1Including six connection terminals
103A fuse3 
11Power cable1 
12Accessories bag1 
13Production disk1Include Analysis application and instruction manual
14Instruction manual1 
15Inspection report1 



Hm405 Hot Sales Current Transformer Test Set in English