Measuring Tools Coating Thickness Gauge

China Measuring Tools Coating Thickness Gauge, Find details about China Measuring Tool, Testing Machine from Measuring Tools Coating Thickness Gauge

Model NO.
CG510PL
Model NO.
CG510PL
Measuring Tools Coating Thickness Gauge

Features:
Two thickness measuring methods adopted, the gauge can be applied to thickness measuring of non-magnetic coating on magnetic metal substrate as well as non-conductive coating on non-magnetic metal substrate; 
5 types of probes can be used (F400, F1, F10, N1, CN02,);
2 measuring modes are available: continuing measuring mode(CONTINUE)and single measuring mode(SINGLE);
2 operation modes are available: direct mode (DIRECT) and batch mode (A-B);
5 statistic values:mean value(MEAN), max. value(MAX), min. value(MIN), numbers of measuring(NO.), standard deviation(S.DEV);
2 methods can be used to calibrate the gauge, and the system error of the probe can be corrected by use of basic calibrating method: 
Storage function: 495 measuring values can be stored; 
Deletion function: delete the single questionable data occurring in measuring, as well as all of the data in memory area to perform the new measuring;
Limit can be set: capable of alarming automatically for measuring values out of limit; and a batch of measuring values can be analyzed via histogram; 
Printing function: measuring value, statistic value, limit and histogram can be printed; 
Capable of communication with PC: measuring values and statistic values can be sent to PC to perform the further process for data; 
Indication of low voltage;
Buzzing indication in the course of operation;
With the function of error warning, error warning can be carried out through display or buzzing;
Two shut down modes are available: manual shut down mode and automatic shut down mode;

INTERNATIONAL STANDARDS:

ASTM B 499, ASTM D 1400, BS 3900-C5-6B, DIN 50981,DIN 50984, ISO 1461,ISO 2360 


Measuring Tools Coating Thickness Gauge


Technical parameters
   Probe modelF400F1F1/90°F5F10
Operating principleMagnetic induction
Measuring range (mm)0~4000~12500~50000~10000
Low range resolution(mm)0.10.1110
Accuracy One-point calibration (mm)±(3%H+1)±(3%H+5)±(3%H+10)
Two-point calibration (mm)±((1~3)%H+0.7)±((1~3)%H+1)±((1~3)%H+5)±((1~3)%H+10)
Measuring conditionsMin curvature radius (mm)Convex 11.5Flatten 510
Diameter of the min area (mm)F3F7F7F20F40
Critical thickness of substrate (mm)0.20.50.512
  
Probe modelN400N1N1/90°CN02N10
Operating principleEddy current
Measuring range (mm)0~400
(Chrome on copper
 
0~1250
0~40)
10~2000~10000
Low range resolution(mm)0.10.1110
 AccuracyOne-point calibration (mm)±(3%H+0.7)±(3%H+1.5)±(3%H+1)±(3%H+25)
Two-point calibration (mm)±[(1~3)%H+0.7]±[(1~3)%H+1.5]___±[(1~3)%H+25]
Measuring conditionsMin curvature radius (mm)Convex1.53Flatten Only flatten25
Diameter of the min area (mm)F4F5F5F7F50