Auto-Control Lager Horizontal Steam Pressure Sterilizer

China Auto-Control Lager Horizontal Steam Pressure Sterilizer, Find details about China Horizontal Steam Pressure Sterilizer, Steam Pressure Sterilizer from Auto-Control Lager Horizontal Steam Pressure Sterilizer

Model NO.
YJ-80d
Design Temperature
144 Degree
Design Pressure
-0.1~0.3 MPa (Guage Pressure)
Door
Single Door Automatic
Trademark
Forever Medical
Transport Package
Standard Exporting Plywood Package
Specification
990*640*1680
Origin
China
Model NO.
YJ-80d
Design Temperature
144 Degree
Design Pressure
-0.1~0.3 MPa (Guage Pressure)
Door
Single Door Automatic
Trademark
Forever Medical
Transport Package
Standard Exporting Plywood Package
Specification
990*640*1680
Origin
China
Large Horizontal Steam Sterilizer
Auto-Control Lager Horizontal Steam Pressure Sterilizer
Features
Horizontal circular inner chamber + jacket structure, safety, heat preservation, and drying function;
Disc type embedded gear + Electric lock door structure,safety and reEiable;
Door seals are pneumatic or self-expanding
Equipped with standard equipment verification interface
Pipeline system for the optimal design, SUS304 pipeline, clamp structure, quick assembly
Control system: HMI man-machine interface, touch screen + microcomputer;
FO value and temperature time double guarantee sterilization effect, with perfect sterilization records;
With program selection, parameter setting, equipment operation, report processing and traceability Functions;
Multiple safety protection(over-temperature, over-pressure protect)
Sterilization process: fabric, equipment, liquid, BD, pressure testing, custom defined multiple procedures
 
Main Technical Parameter
Design pressure: -0.1~0.3Mpa
Design temperature : 144
Working pressure : 0.245Mpa
Working Temperature : 105-138C
Vacuum : -0.086Mpa
Temperature Equilibrium: <+2.0C
Water Pressure : 0.1-0.2Mpa
Compressed air pressure : 0.4~0.7Mpa
Steam Pressure: 0.3-0.7Mpa
Power voltage: Three-phase five-wire AC 380V 50HZ

Model&Parameter(Without Pulse Vacuum)
ModelOverall
Dimensions
(L××H)mm
Chamber Size
(0×L)mm
Steam
Consumption
(KG)
Water
Consumption
(KG)
Power(K
W)
Net
Weigh
(KG)
YJ-80D990×640×1680∅420×580≤9≤30≤2+(9)220
YJ-100D1160×650×1680∅420×750≤10≤30≤2+(9)250
YJ-120D1290×650×1680∅420×880≤11≤30≤2+(9)280
YJ-150D1290×690×1680∅472×880≤12≤10≤2+(12)350
YJ-200D1560×690×1680∅472×1150≤13≤190≤2+(12)370
YJ-300D1430×850×1760∅620×995≤18≤200≤2+(15)450
YJ-400D1755×850×1760∅620×1320≤22≤200≤2+(15)510
 
Model&Parameter(With Pulse Vacuum)
ModelOverall
Dimensions
(L×Wx)
Chamber
Size
(0×L)mm
Steam
Consumption
(KG)
Water
Consumption
(KG)
Power
(KW)
Net Weigh
Single/Dou
ble door
(KG)
YJ-80D (S)M990×640×1680∅420×580≤10≤30≤2+(12)220
YJ-100D(S)M1160×650×1680∅420×750≤11≤30≤2+(12)250
YJ-120D(S)M1290×650×1680∅420×880≤12≤30≤2+(12)280
YJ-150D(S)M1290×690×1680∅472×880≤13≤190≤2+(15)350
YJ-200D(S)M1560×690×1680∅472×1150≤15≤190≤2+(15)370
YJ-300D(S)M1430×850×1760∅620×995≤20≤200≤2+(18)450
YJ-400D(S)M1755×850×1760∅620×1320≤25≤200≤2+(18)510
 
Note:
1, For example2+(18), the first 2 is the power of the system, and the 18 is the
power of the built-in steam generator.But the steam generator is optional.
2, Model "D"means single door,"S"means double,"M" means pulsation
vacuum.
 
STERILIZATION CONTROL PRINCIPLES
Pulsating vacuum sterilizer is strictly designed and manufactured in accord
with GMP technical Standard. It has passed ISO9001 quality management
qualification standard and ISO13485:2003 Certificate of Quality Management
System for Medical Devices.
The relevant data can be saved and printed automatically.
This autoclave is suitable for hospital, scientific research institute and other
units to sterilize asepsis clothes, tools, ulture medium and so on,
 
Technical parameters and configuration list
Basic technical parameters
Applicationasepsis clothes, tools, culture medium 
Main process• Bowie Dick cycle
• Chamber leak test cycle
• Sterilizing program for textiles and tools
(Loading→Preheating→Chamber
vacuumize→Heating→
Sterilizing→Drying→End)
• Sterilizing program for liquid medium
(loading→Preheating→Heating→Sterilizing→Slowly
discharge and cooling→End)
 
Cycle time per batchAbout 40-70 minutes 
Design temperature144ºC 
Design pressure-0.1~0.3Mpa(guage pressure) 
Standard of pressure vesselChina standard GB150 pressure vessel 
Chamber
Material contact with productsThickness:4mm, SS304
Inner surface finish0.4μm
DoorSingle door automatic
sealHigh quality silicone seal ring,temperature resistant
250ºC. airtight seal
Jacket
MaterialThickness:5mm,Q235B
Heat insulation materials and
thickness
Aluminum silicate, T=30mm
Wrapper materialsAluminum sheets
Piping System
Vacuum pumpGerman SpeckWater ring. low noise,high
va cuum, easy maintenance
Air filters um 0.22Aseptic level filtration
PumpL'OU. ZhejiangLow flow, high lift
Pressure gaugesChangzhouClass 1.6. stainless steel dial
Solenoid valveAirtac TaiwanReliable action, long life
Control system
Touch screenKunlun TongtaiHuman-machine interactive
program selection, parameter
setting, easy operation
PrintersBeijing SpriteOutput of sterilization report
Temperature sensorGERMANY isotempHigh precision temperature
conversion
Pressure sensorDANFOSSHigh precision temperature
conversion
Others
Sterilization rackDENGGUAN MedicalSUS304 stainless steel,
beautiful and durable
Steam generatorDENGGUAN MedicalSelf-produced saturated
steam, built-in steam generator
Outer panelDENGGUAN MedicalCarbon steel spray, beautiful
and generous
Auto-Control Lager Horizontal Steam Pressure SterilizerAuto-Control Lager Horizontal Steam Pressure Sterilizer