Sqdy421f Manual Hydraulic Emergency Shut-off Valve

China Sqdy421f Manual Hydraulic Emergency Shut-off Valve, Find details about China PVC Ball Valve, Tanker Ball Valve from Sqdy421f Manual Hydraulic Emergency Shut-off Valve

Model NO.
SQDY421F
Temperature
High Temperature
Application
Industrial Usage, Water Industrial Usage, Household Usage
Manufacturer Level
Top Level
Trademark
Jun Kang
Transport Package
Wooden Box
Specification
Stainless Steel
Origin
China
HS Code
8481100090
Model NO.
SQDY421F
Temperature
High Temperature
Application
Industrial Usage, Water Industrial Usage, Household Usage
Manufacturer Level
Top Level
Trademark
Jun Kang
Transport Package
Wooden Box
Specification
Stainless Steel
Origin
China
HS Code
8481100090
                                           The Introduction of Products
SQDY421F Manual hydraulic emergency shut-off valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
SQDY421F Manual hydraulic emergency shut-off valve is a necessary valve accessory in piping system. It is mainly used to quickly close the inlet and outlet of the pipeline at a distant location in case of emergency. Can implement remote control opening and closing, only need to press the control button to enable the other matters in the specified time to complete, such as installing remote signal feedback system, can be in the remote control room directly learn the valve running state.

The performance specification
SpecificationsDN25~DN400
Using the pressure1.0 ~ 6.4 Mpa
The use of temperature- 30 ºC ~ 60 ºC
Use mediumLiquefied petroleum gas, natural gas and other gases
Air pressure0.3 ~ 0.6 Mpa

Action principle and structure description
1. When the valve is in use, first turn the hand wheel counterclockwise to the end, and then use a fixed hand wheel to fix the nut, in case the manual device pulls the piston so that the seal is not in place and the seal is not sealed (the valve has been adjusted before leaving the factory). Under the condition of no external pressure operation, the valve disc is normally closed. When used in the system, the hydraulic source of the hand oil pump pushes the piston to move up to open the valve. When the valve needs to be closed or there is an emergency, the hydraulic source pressure can be discharged and the valve will automatically close.
2. The valve is equipped with operating handwheel to open or close the valve when there is no air source.
3. When the disc is closed, the pressure is achieved by relying on the hydraulic source of the hand pump or the operating handwheel.
4. The flow direction of valve working medium should be high into low out, and the flow direction of ordinary stop valve is just the opposite.
5. The connecting dimensions of valve flanges shall be in accordance with JB/T79.1-94 "Convex Integral cast steel flanges" or HG20592-97.

Main external dimensions and connection dimensions
DNDD1D2bFz-Ф
2511585651624-Ф14
32135100781824-Ф18
40145110851824-Ф18
501601251002034-Ф18
651801451202238-Ф18
801951601352238-Ф18
1002301901602438-Ф23
1252702201882838-Ф25
1503002502183038-Ф25
20036031027834312-Ф25
25042537033236312-Ф30
30048543039040316-Ф30
35055049044844416-Ф34
400610550-3-
505
48416-Ф34
  
Precautions for storage, installation and use
1. Both ends of the valve path must be covered with protective cover, stored in a dry, ventilated room, such as long-term storage should be regularly checked to prevent corrosion;
2. Do not remove the dust cover before installation of the valve, so that there is no dirt in the valve;
3. The valve can be installed in horizontal or vertical pipe for use, remove the dust cover when installing, and blow the pipe clean with air first, so as not to bring dirt into the valve cavity;

 
The fault phenomenonReasonElimination method
Leakage from flange sealing surface1. Flange gasket damage or sealing surface damage;
2. Flange connection bolts are firm and uneven.
1.Replace gasket of flange sealing surface;
2.Sealing surface to repair the bump;
3.Uniform and strong flange connection bolts.
Leakage between disc and seat face1. There is damage or dirt on the sealing surface;
2. Seat spring failure.
1. Repair the sealing surface and remove dirt;
2. Replace the seat spring.
Open disc cylinder leakage1. Valve piston and cylinder body damage;
2. The O-ring of the piston is damaged.
1. Trim the roughness of cylinder wall and piston;
2. Replace the O-ring

Other Products
QDQ421F Ammonia Emergency Cut-Off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
QDQ421F Ammonia emergency cut-off valve is suitable for ammonia/gas storage tank, pipeline inlet and outlet control cut-off flow safety valve. In case of equipment failure, corrosion damage, seal failure, in the event of an emergency or an emergency, it is used to cut off the upstream gas source to avoid the expansion of the accident scope, control the impact of the accident, and reduce the loss of the accident.

Pneumatic emergency cut-off valve is equipped with low melting point (fusible alloy) plug, in the external temperature ≥80ºC fusible alloy melting plug pipe pressure relief cut-off valve quickly closed, to ensure the safety of storage tank system.

Ammonia emergency cut-off valve (pneumatic emergency cut-off valve) is composed of multi-spring pneumatic film actuator or floating piston actuator and regulating valve. It receives the signal of regulating instrument and controls the cutting, switching or switching of the fluid in the process pipeline. It has the characteristics of simple structure, sensitive reaction and reliable action. It can be widely used in petroleum, chemical industry, metallurgy and other industrial production departments. The emergency shut-off valve air source requires filtered (compressed air) nitrogen.


The performance specification
Classes2.5/4.0Mpa
Cylinder working pressure0.3-0.6Mpa
The use of temperature-40~+80ºC
The cylinder uses mediumNitrogen, anhydrous air
Use mediumNatural gas, liquefied gas, liquid ammonia, gas
Fuse closed time+ 70 ºC
Closing time≤5 seconds
Cylinder opening pressure≥0.3-0.6Mpa
Seal ring, O-ringPolytetrafluoroethylene, butane rubber
The valve bodyCast steel, stainless steel 304,316,316L
Spring50CrVA (Spring steel)
Oil cylinder, pistonChromium stainless steel
Seal ring, O-ringPTFE, butane rubber
TypeOften closed

Liquid ammonia emergency cut-off valve -- mounting size unit (mm)
DNLHDD1D2bfz-d
151302159565451624-14
2015025510575551624-14
2516028511585651624-14
32180300135100781824-18
40200320145110851824-18
502303801601251002034-18
652904201801451202238-18
803104501951601352238-18
1003505202301901602438-23
1254005582702201882838-23
1504807503002502183038-25
20060095036031027834312-25
250650105042537032236312-30
300750112048543039040316-30

Application rules
Pneumatic cutting valve cylinder opening pressure ≥ 0.3-0.6mpa, the daily working pressure of the cylinder, shall not be less than 0.4mpa, to ensure the normal work of the valve.
Emergency cut-off valve should not be opened for a long time to avoid spring fatigue failure.


Installation Precautions
1. During storage, each external access of the valve is closed with plugs or cover plates and stored in a dry and ventilated room. Long-term storage should be regularly checked to eliminate dirt and coated with anti-rust oil on the processing surface to prevent corrosion.
2. Before installation, clean the valve and tighten the joint of each thread.
3. The cut-off valve adopts the principle of check valve, can only be one-way truncation, installation must pay attention to the valve mark, the end to be protected as the valve entrance. Valve installation should be noted: high in low out.
4. Flange sealing surface form, pressure grade and connection standard must be indicated when ordering.


Liquid Ammonia Emergency Cut-off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off ValveQDY421f-16/40c liquid ammonia emergency cut-off valve combines the advantages of globe valve, check valve and pneumatic valve, using the lifting structure of globe valve and check valve to prevent the principle of media backflow. Shut-off valve has excellent technical performance, low load loss and high reliability, and remote hand pump matching use, using manual hydraulic control valve open - close.

The cut-off valve is installed on the liquid ammonia, gas storage tank station or gas pipeline, so that in case of leakage or even fire on the pipeline or storage tank, the staff can relieve pressure through the remote oil pump, or melt the (fusible alloy) at 80ºC high temperature, the valve cylinder automatically relieve pressure, the valve quickly shut down and stop leakage. To protect personal safety, cut-off valve is the ideal choice of chemical dangerous goods closure products.

Double oil pump control multi-valve working principle
The pipeline installation of multiple emergency shut-off valves should be controlled by two hand oil pumps, one of which is working and the other is standby to prevent the valve from working properly when one oil pump is damaged. In the case of multiple emergency shut-off valves, one (J23H-40P) needle valve is used for control. So that the service can be closed using a needle valve.
Classes20K 1.0Mpa
Cylinder working pressure≤6.0.Mpa
The use of temperature-40~+80ºC
The cylinder uses mediumMix spindle oil and transformer oil
Use mediumNatural gas, liquefied gas, liquid ammonia, gas
Fuse closed time+ 70 ºC
Closing time10 seconds or less
Cylinder opening pressureAcuity 2.0 MPa
Seal ring, O-ringPolytetrafluoroethylene, butane rubber
The valve bodyCast steel, stainless steel 304,316,316L
Spring50CrVA (Spring steel)
Oil cylinder, pistonChromium stainless steel
TypeOften closed

Liquid ammonia emergency cut-off valve -- mounting size unit (mm)
DNLHDD1D2bfz-d
151302159565451624-14
2015025510575551624-14
2516028511585651624-14
32180300135100781824-18
40200320145110851824-18
502303801601251002034-18
652904201801451202238-18
803104501951601352238-18
1003505202301901602438-23
1254005582702201882838-23
1504807503002502183038-25
20060095036031027834312-25
250650105042537032236312-30
300750112048543039040316-30

Installation Precautions
1. During storage, each external access of the valve is closed with plugs or cover plates and stored in a dry and ventilated room. Long-term storage should be regularly checked to eliminate dirt and coated with anti-rust oil on the processing surface to prevent corrosion.
2. Before installation, clean the valve and tighten the joint of each thread.
3. The emergency cut-off valve adopts the principle of check valve, which can only be cut off. The valve mark must be paid attention to during installation, and the end to be protected is used as the valve entrance. Valve installation direction: high in low out.
4. Flange sealing surface form, pressure grade and connection standard must be indicated when ordering.


QGY43F Hydraulic Vehicle Emergency Shut-Off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
In the important facilities of transportation and storage equipment such as liquefied gas tank car, train tank car, ball tank, storage tank, etc., the plug of the low melting point material valve is installed on the oil pressure pipeline or hand pull device of the valve. When loading and unloading liquefied gas, if there is an accident, The emergency cut-off device protects the safety of the equipment, the safety of the operator and the surrounding environment, preventing the occurrence of a major accident.
 
The performance specification
Specifications (DN)Nominal pressure (Mpa)Seal test pressure (Mpa)Operating temperature (ºC)Applicable mediumControl cylinder part
Disc opening height (mm)Use mediumDisc opening pressure (Mpa)
252.52.75- 40 ºC ~ + 50 ºCLiquefied petroleum or liquid ammonia, etc122# spindle oil or 13# machine oil2.0-4.0Mpa
502.52.7518

Function principle and structure description:
1. without external pressure valve operation case, the disc in a normally closed state, tank car, spherical tank, storage tank system when used by hand pump pressure, open the valve or a manual device, under the oil pressure or a manual device to use that valve is fully open, when you need to close the valve or when there is an emergency, can drain off or let go of the manual hydraulic system, the valve automatically shut down, Or because of the low melting point of the pipe plug in the temperature rise to achieve self-melting.
2. The connecting size of valve flange is in accordance with JB/T79.1-94 "Convex integral cast steel flange" size standard.


Main external dimensions and connection dimensions (refer to composition)
DN
SIZE
D
D1
D2
D3
D'
D1'
D2'
D3'
b
f
z-Фd
b'
f'
z'-Фd'
H
25
160
125
102
88
115
85
68
58
22
3
4-18
16
2
4-14
250
50
195
160
135
121
160
125
102
88
26
3
8-18
24
3
4-18
338

Main Parts
Part nameMaterial
The valve bodyWCB/1Cr18Ni9Ti
Valve ringF4
The disc2Cr13/1Cr18Ni9Ti
Oil cylinder45#/1Cr18Ni9Ti
Spring spring1Cr18Ni9Ti /60Si12mn
Live plug2Cr13/1Cr18Ni9Ti
Precautions for storage, installation and use:
1. Protective cover must be added at both ends of the valve access and stored in a dry and ventilated room. If stored for a long time, it should be checked regularly to prevent corrosion.

2. before the installation of the valve do not remove the dust cover, so that there is no dirt in the valve;

3. when installing, remove the dust cover, and blow the pipeline clean with air first, so as not to bring dirt into the valve cavity;

4. After 12-14 hours every day, the valve disc should be closed in time when the system does not work to avoid long-term compression of the spring and reduce the reliability of long-term use of the valve.

JUNKANG FLUID TECHONOLOGY CO., LTD
Professional Control Valve Manufacturer
Sqdy421f Manual Hydraulic Emergency Shut-off ValveCompany Profile
Junkang Fluid Technology Co., Ltd. is an expert manufacturer of regulating valves and pressure relief valves. The company is located in the "township of pumps and valves in China" - Oubei Sanqiao Industrial Zone. It is 30 kilometers away from Wenzhou Longwan International Airport, 12 kilometers away from Wenzhou South Station and 10 kilometers away from Yongjia Station.
The company has strong technical force, with a number of sets of advanced production equipment and testing equipment. The technical team has rich product experience. The company has large-scale production. Products with reasonable design, beautiful appearance, stable quality and other characteristics, are widely used in power plants, iron and steel plants, oil extraction, refining and chemical industry, paper making, metallurgy, medicine, construction and other fields, long-term trust and praise by new and old users.
Junkang Valve has always been market-oriented, strict quality control, to ensure that the interests of users are effectively guaranteed. The company adheres to the "high quality as the main line, excellence as the goal", adheres to the "business integrity, quality innovation" business philosophy, and in the fierce market competition to establish a mutually beneficial sales network, highlighting the unique advantages of Junkang Valve.


Production Equipment
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
Certificate
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
Sqdy421f Manual Hydraulic Emergency Shut-off Valve
 
After- Sale Service can be Provided
ADD:Dongou Industial Area, Oubei Town, Yongjia County, Wenzhou City, Zhejiang, China

FAQ
1.What's Your Strong Products?
The control valve series are our strong products.

2.If The Factory Has The Control Valve In Stock?
There are no control valve in stock at  anytime, because this kinds of products are made by client's requirements


3.Can I request to advance the shipment?
It should be depends on whether there is sufficient inventory in our warehouse.

4.Can I request to change the form of packaging and transportation?
Yes, we can change the form of the packaging and transportation according to your request, but you have to bear their own costs incurred during this period and the spreads.
The  End