200kv Partial Discharge Measuring Instrument

China 200kv Partial Discharge Measuring Instrument, Find details about China AC Hipot Tester, High Voltage Tester from 200kv Partial Discharge Measuring Instrument

Weight
Customized
Power Source
AC220V
Capacity(kVA)
5-300 or Customized
Regulator Capacity(kVA)
5 -300 or Customzied
Working Time
5 Mins or Customized
Output(Kv)
50-300 or Customzied
PC Amount
Less Than 5 PC or Customzied
Wave Distortion
<3
Impedance Voltage
<8
No-Load Current
<6
Certificate
CE,SGS
Standard
IEC
Trademark
HMDQ
Transport Package
Wooden Box with Foam Inside
Specification
test transformer
Origin
Hubei, China(Mainland)
HS Code
9030339000
Weight
Customized
Power Source
AC220V
Capacity(kVA)
5-300 or Customized
Regulator Capacity(kVA)
5 -300 or Customzied
Working Time
5 Mins or Customized
Output(Kv)
50-300 or Customzied
PC Amount
Less Than 5 PC or Customzied
Wave Distortion
<3
Impedance Voltage
<8
No-Load Current
<6
Certificate
CE,SGS
Standard
IEC
Trademark
HMDQ
Transport Package
Wooden Box with Foam Inside
Specification
test transformer
Origin
Hubei, China(Mainland)
HS Code
9030339000
100KV Partial Discharge measuring instrument Sf6 Gas Pd Free Testing Transformer hipot tester  Dielectric Strength  hv test set 

I. Summary

Transformer partial discharge detection device(sf6 high voltage test set) is a necessary test device for power equipment detection and preventive test.
Because of the sf6 high voltage test set excellent insulation and arc extinguishing performance and nonflammability, the six sulfur fluoride gas has been widely applied as a new insulating medium.
After years of efforts, our company has successfully developed a partial discharge detection device for transformers. Compared with the traditional oil immersion light test transformer, this series of the high voltage test set reduce the weight by 20% - 60% (depending on the voltage and capacity grade), and without oil pollution, the voltage level of the single test transformer can reach 300KV. Due to the adoption of the new production technology, the technical performance of the product has been greatly improved, especially for field work and frequent mobile working conditions.

200kv Partial Discharge Measuring Instrument

II. Technical indicators and parameters
1.No-load current is 4 to 9%, and impedance voltage is 4 to 10%.
2.Specifications and running time of high voltage test set.
3.More specifications can be customzied 

 
ModelYDQ capacity
KVA
Regulator capacity
KVA
Working time
min
ydq-21.51.5≤5
ydq -333≤5
ydq -555≤5
ydq -101010≤5
ydq -202020≤5
ydq -303030≤5
ydq -505050≤5
Transformer's technical parameters
 
Input (V)200200400400400400400
Output
(KV)
50100150200250300400
PC<=3<=3<=3<=3<=5<=10<=10
Impedance%<=8<=8<=8<=8<=10<=10<=10
No-load current%<=6<=6<=6<=6<=5<=5<=5
Distortion%∠3∠3∠3∠3∠3∠3∠3 

III. Main Parameter for 10kVA/100kV power frequency hipot tester partial dsicharge test equipment
1. gas testing transformer specifictaion
Model No.: HM-YDQW-10kVA/100kV
Phase :single phase
Frequency:50Hz                                       
Rated capacity:10kVA
Input voltage:0.2kV  
Input current:50A       
Output voltage:0~100kV
Output current: 0.1A
Waveform deviation factor:≤3%
Measurement winding voltage ratio:1000:1
pC amount: ≤5PC,at rated 60%voltage,3PC
2.Manual console specification
Model No.:HMTC-100
Phase:single phase                                            
Frequency:50Hz
Rated capacity:10kVA
Input voltage:0.2kV 
Input current:50A       
Output voltage:0~200V
Output current:50A
Waveform deviation factor:≤3%
Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1min
Insulation level:<0.3%
Noise: ≤60dB
pC amount: ≤5PC,at rated 60%voltage,3PC

3.  Coupling capacitor specification
Mode:  HM-TRF-100-0.01
Rated frequency: 50Hz
Capacity: 500PF±10%
Rated voltage : 100kV                        
Divider ratio: 1000:1
Dielectric loss:<0.5%
Precision: 1.5
Partial discharge: ≤5PC,at rated 60%voltage,3PC
4.
Isolation transformer technical parameterMode: HM-GLB-LNF-100
Rated capacity:10kVA                           
Input voltage:220V
Output voltage:220V
Output current:50A
Rated frequency: 50~60Hz
Number of line:2 line
Quality factor of filter reactor:>70
Partial discharge: ≤5PC,at rated 60%voltage,3PC

200kv Partial Discharge Measuring Instrument



IV. Related Products.
 
200kv Partial Discharge Measuring Instrument
200kv Partial Discharge Measuring Instrument
200kv Partial Discharge Measuring Instrument


 
200kv Partial Discharge Measuring Instrument
200kv Partial Discharge Measuring Instrument
200kv Partial Discharge Measuring Instrument



200kv Partial Discharge Measuring Instrument
200kv Partial Discharge Measuring Instrument
200kv Partial Discharge Measuring Instrument