China Sine Wave UPS Inverter 2000W, Find details about China Sine Wave Power Inverter, Safe Power Inverter from Sine Wave UPS Inverter 2000W
2000W Modified Sine Wave Invrter Technical Data | ||||
Item No. Function | JGM2000-121 | JGM2000-241 | JGM2000-122 | JGM2000-242 |
Rated power | 2000W | |||
Peak power | 4000W | |||
Inupt voltage | DC12V | DC24V | DC12V | DC24V |
Output voltage | 100-120VAC±5% | 210-240VAC±5% | ||
Output frequency | 50±2HZ or 60±2HZ | |||
Output waveform | Modified sine wave | |||
Idle consumption | ≤0.8A | ≤0.6A | ≤0.8A | ≤0.6A |
Converting efficiency | Max≥90% | |||
USB Output | DC5V 500mA(Optional) | |||
Working voltage | DC10-15V | DC20-30V | DC10-15V | DC20-30V |
Under-voltage warning voltage | DC10.5±0.3V | DC21.0±0.5V | DC10.5±0.3V | DC21.0±0.5V |
Under-voltage protection voltage | DC9.5±0.3V | DC19±0.5V | DC9.5±0.3V | DC19±0.5V |
Under-voltage auto recover voltage | DC12.0±0.3V | DC24.0±0.5V | DC12.0±0.3V | DC24.0±0.5V |
Over-voltage protection voltage | DC15.5±0.5V | DC31.0±1V | DC15.5±0.5V | DC31.0±1V |
Over-voltage recover voltage | lower than DC15V | lower than DC30V | lower than DC15V | lower than DC30V |
Warning and indicating light function | Input revers polarity protection | The fuse will be burned,and the inverter will work again after replaced the burned fuse | ||
Under-voltage protection | LED red light,warning,output closed(it will be automatic recovery after the voltage become regular) | |||
Over-voltage protection | LED red light,output closed(it will be automatic recovery after the voltage become regular) | |||
Over-load protection | LED red light,output closed(it will be automatic recovery after protection) | |||
Over-temperature protection | LED red light,warning,output closed(it will automatic recovery after temperature lowered) | |||
Short-circuit protection | LED red light,output closed(it will automatic recovery after protection) | |||
Starting mode | Hard start | |||
Cooling mode | The cooling fan will work when it with 30% load or inner temperature reach 50ºC | |||
Working environment temperature | -20~+45ºC | |||
Storage environment temperature | -30~+60ºC |