Three-Phase AC-DC Instrument Test Equipment

China Three-Phase AC-DC Instrument Test Equipment, Find details about China Instrument Test Equipment, Electrical Measurement Equipment from Three-Phase AC-DC Instrument Test Equipment

Model NO.
GF3600
Customized
Customized
Accuracy
0.05%
Phase
0-360.000
Weight
135kg
Size
1800X800X750mm
Harmonic
2~31th
DC Output Capacity
30W
Certificate
CE, ISO9001:2000
Frequency
45-65Hz
Trademark
GFUVE
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Origin
Beijing, China
HS Code
9030849000
Model NO.
GF3600
Customized
Customized
Accuracy
0.05%
Phase
0-360.000
Weight
135kg
Size
1800X800X750mm
Harmonic
2~31th
DC Output Capacity
30W
Certificate
CE, ISO9001:2000
Frequency
45-65Hz
Trademark
GFUVE
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Origin
Beijing, China
HS Code
9030849000
GF3600 THREE-PHASE AC-DC INSTRUMENT TEST EQUIPMENT
Three-Phase AC-DC Instrument Test Equipment
It is suitable for power grid company measuring and testing center, power supply company and power plants measuring department, national levels measuring and testing institutions, also suitable for railway, petroleum, chemical industry and large industrial and mining enterprises, etc.
Introduction
The device by program-controlled three-phase standard power resource, DC standard power resource, three-phase multi-function meter and the meter with standard and management software of the computer.The technical index device accord with country and industry related standards and verification regulation.Standard resource meter output, safe and reliable, easy to use, standard meter precise meter, the function is all ready, a meter is multi-purpose.The source of computer meters and verification system, to have corresponding output information is power inspection meter can realize the automatic verification, and meet the requirements of the rules are verification report.
Checking commonly used instructions instrument, industrial frequency and DC digital instrument, transducer and electric energy meter, etc.
Feature
Checking AC sample device error.
The instrument type are the verification:AC/DC voltmeter, ammeter, single/three-phase active, reactive power meter, phase meter, for access to power, frequency meter, synchronous meter, etc.
The transducer type are the verification, AC/DC voltage transducer, current transducer, single/three-phase active, reactive power transducer, phase transducer, a power factor transducer, frequency transducers.
Verification of watt-hour meter can be species are:Electronic type and inductive single-phase and three-phase meritorious electric energy meter and reactive watt-hour meter.
To set and measuring 2 ~ 31 times harmonic.
Wide measuring range, high stability, high resolution, low distortion degree.
Automatic data about the certificate format have various forms, convenient inquires the and print
Through the computer control, it can realize the automatic verification watt-hour meter and transducer, semi-automatic verification all kinds of instruction machine
It is block structure, facilitate inspection, and it can be used independently
Automatic failure detection, can prevent the damage of equipment wrong operation
Many kinds of models the device preset portable instrument parameters, reduce the verification personnel the input workload.
Standard meter, communication standard resource, DC standard resource are software calibration
Technical ParametersElectrical parametersAC Voltage output and measurementAC Current output and measurementPower output and measurementEnergy measurementPhase output and measurementPower factor output and measurementFrequency output and measurementHarmonicDC Voltage outputDC Current outputMechanical parametersEnvironmental conditions
Accuracy class 0.05%, 0.1%
Power supplyAC 220V ± 10% or AC 110V ± 10%, 50/60Hz
U1, U2, U3 Range10V, 20V, 50V, 100V, 200V, 400V, 800V
Output range(0-120%)% RG
Adjustment resolution0.01% RG
Output stability0.01%/min
Measurement accuracy0.05% RG
Output load capability50VA
Measurement resolution≤5×10-5 RG
I1, I2, I3 Range0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A
Output range(0-120)% RG
Adjustment resolution0.01% RG
Output stability0.01%/min
Measurement accuracy0.05% RG
Output load capability100VA 
Measurement resolution≤5×10-5 RG
Output stability0.01%/1min
Active accuracy0.05% RD (0.01A-100A, 30V-600V, PF ≥0.5L or PF ≥0.8C)
Reactive accuracy0.1% RD (0.01A-100A, 30V-600V, PF ≥0.5)
Measurement resolution≤5×10-5 RG
Active accuracy0.05% RD (0.01A-100A, 30V-600V, PF ≥0.5L or PF ≥0.8C), 
0.1% RD (0.05A-100A, 30V-600V PF ≥0.5C)
Reactive accuracy0.1% RD 0.05A-100A, 30V-600V PF ≥0.5
Setting range of test pulse No.1-9999999
Max. frequency of receiving pulse2MHz
Output range0°-359.99°
Adjustment resolution0.01°
Measurement accuracy0.05°
Measurement resolution0.001°
Output range-1 to 0 to +1
Measurement accuracy0.0005
Measurement resolution0.0001
Output range45-65Hz
Adjustment resolution0.001Hz
Measurement accuracy0.005Hz
Measurement resolution0.001Hz
Times2 to 31
Resolution0.1% (compared with fundamental wave)
Contents0-30%
Phase0°-359.99°
Range100mV, 300mV, 1V, 3V, 10V, 30V, 100V,  300V, 600V, 1000V
Setting range0-1000V
Regulated step value0.002% RG
Accuracy0.03% RD + 0.02% RG
Stability0.01%RG/1min
Output load capability25VA 
Ripple wave and noise0.1-100KHz
Output ≤100 VRipple wave ≤2mVrms
Output > 100 VRipple wave ≤10mVrms
Range10μA, 30μA, 100μA, 300μA, 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1 A, 3 A, 10 A, 30 A
Setting range0-30A
Regulation resolution≤0.02% RG
Accuracy0.03% RD + 0.02% RG
Stability0.01%RG/1min
Output load capability30VA 
Dimension (L×W×H) (mm)1800x800x750
Weight (kg)135
Operating temperature0°C to 40°C
Relative humidity≤85%