China Switch 155W 13.8V UPS Power Supply with Battery Backup Function, Find details about China UPS Power Supply, 12V Power Supply Charger from Switch 155W 13.8V UPS Power Supply with Battery Backup Function
SPECIFICATION | ||||||
MODEL | AD-155A | AD-155B | AD-155C | |||
OUTPUT | ||||||
Output number | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 13.8V | 13.3V | 27.6V | 27.1V | 54V | 53.5V |
Rated Current | 10.5A | 0.5A | 5A | 0.5A | 2.7A | 0.2A |
Current Range | 0~11.5A | 0-0.5A | 0~5.5A | 0-0.5A | 0-2.7A | 0-0.5A |
Rated Power | 151.55W | 151.55W | 156.5W | |||
Ripple & Noise | 150mVp-p | -------- | 150mVp-p | -------- | 240mVp-p | -------- |
Voltage Adj. Range | CH1:12~14.5V | CH1:24~29V | CH1:48-58V | |||
Voltage Tolerance | ±2.0% | -------- | ±1.0% | -------- | ±1.0% | -------- |
Line Regulation | ±0.5% | -------- | ±0.5% | -------- | ±0.5% | -------- |
Load Regulation | ±0.5% | -------- | ±0.5% | -------- | ±0.5% | -------- |
Setup, Rise Time | 1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load | |||||
Hold Up Time | 24ms/230VAC 20ms/115VAC at full load | |||||
INPUT | ||||||
Voltage Range | 88~264VAC 47~63Hz; 124~370VDC | |||||
AC Current | 2.5A/115VAC 1.5A/230VAC | |||||
Efficiency | 80% | 84% | 84% | |||
Inrush Current | Cold start 20A/115VAC 40A/230VAC | |||||
Leakage Current | <1mA /240VAC | |||||
PROTECTION | ||||||
Over Load | CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power | |||||
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse | ||||||
Over Voltage | CH1:15.87~18.63V | CH1:31.74~37.26V | CH1:62.1 ~ 72.9V | |||
Protection type:Shut down o/p voltage, re-power on to recover | ||||||
Battery Low | 10V±0.8V | 19.5V(+1.5V,-1V ) | 39V±2V | |||
ENVIRONMENT | ||||||
Working Temp. | -10~+60ºC (Refer to "Derating Curve") | |||||
Working Humidity | 20~90%RH non-condensing | |||||
Storage Temp., Humidity | -20~+85ºC,10~95%RH | |||||
Temp. Coefficient | ±0.03%/ ºC(0~50ºC ) | |||||
Vibration | 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes | |||||
SAFETY &EMC | ||||||
Safety Standards | UL60950-1, TUV EN60950-1 | |||||
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25ºC /70%RH | |||||
EMC Emission | Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 | |||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A | |||||
OTHERS | ||||||
Dimension | 199*110*50mm (L*W*H) | |||||
Weight | 0.88Kg | |||||
Packing | 16pcs/carton/15kg/0.95CUFT | |||||
NOTE | ||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |