Features:
Max. efficiency 98.8%
Wide voltage range and low startup voltage
3/4 MPPT design with precise MPPT algorithm
THDi<3%, low harmonic distortion against grid
Anti-resonance, supporting over 6MW parallelled in one transformer
Perfect commercial site monitoring solution
130% DC overload ratio, 13A input for each PV string
Strings intelligent monitoring, Smart I-V curve scan
Fuse free design to avoid fire hazard
Type II surge arrester for both DC and AC
Natural convection, Fan-less design, longer lifesLeakage current repression technology
Volt-watt work mode integrated
DC input reverse alarm
Intergrated Export Power Manager (EPM)
DatasheetModel Name | Solis-25K-5G | Solis-30K-5G | Solis-33K-5G | Solis-36K-5G | Solis-40K-5G | Solis-40K-HV-5G | Solis-50K-HV-5G |
Input DCRecommended max. PV power | 33kW | 39kW | 43kW | 47kW | 52kW | 52kW | 65kW |
Max. input voltage | 1100V |
Rated voltage | 600V |
Start-up voltage | 180V |
MPPT voltage range | 200-1000V |
Max. input current | 26A/26A/26A | 4*26A |
Max. short circuit current | 40A/40A/40A | 4*40A |
MPPT number/Max. input strings number | 3/6 | 4/8 |
Output ACRated output power | 25kW | 30kW | 33kW | 36kW | 40kW | 40kW | 50kW |
Max. apparent output power | 27.5kVA | 33kVA | 36.3kVA | 39.6kVA | 44kVA | 44kVA | 55kVA |
Max. output power | 27.5kW | 33kW | 36.3kW | 39.6kW | 44kW | 44kW | 55kW |
Rated grid voltage | 3/N/PE, 220/380V, 230/400V | 3/PE, 480V |
Rated grid frequency | 50/60Hz |
Rated grid output current | 38.0A/36.1A | 45.6A/43.3A | 50.1A/47.6A | 54.7A/52.0A | 60.8A/57.7A | 48.1A | 60.1A |
Max. output current | 41.8A | 50.2A | 55.1A | 60.2A | 66.9A | 53.0A | 66.2A |
Power Factor | >0.99 (0.8 leading - 0.8 lagging) |
THDi | <3% |
EfficiencyMax. efficiency | 98.8% |
EU efficiency | 98.3% |
ProtectionDC reverse-polarity protection | Yes |
Short circuit protection | Yes |
Output over current protection | Yes |
Surge protection | DC Type II / AC Type II |
Grid monitoring | Yes |
Anti-islanding protection | Yes |
Temperature protection | Yes |
Strings monitoring | Yes |
I/V Curve scanning | Yes |
Anti-PID function | Optional |
Integrated AFCI (DC arc-fault circuit protection) | Yes |
Integrated DC switch | Optional |
General DataDimensions (W*H*D) | 647*629*252 mm |
Weight | 45kg |
Topology | Transformerless |
Self consumption | <1W (night) |
Operating ambient temperature range | -25 ~ +60°C |
Relative humidity | 0-100% |
Ingress protection | IP65 |
Cooling concept | Natural convection |
Max. operation altitude | 4000m |
Grid connection standard | VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, IEC61727, DEWA |
Safety/EMC standard | IEC 62109-1/-2, IEC 62116, EN 61000-6-1/-2/-3/-4 |
FeaturesDC connection | MC4 connector |
AC connection | OT terminal |
Display | LCD |
Communication | RS485, Optional: Wi-Fi, GPRS |