China Solis 5g on Grid Three Phases Inverter for Solar Power System 30kw 33kw 36kw 40kw 50kw, Find details about China Solis Solar Inverter, Grid Tie Solar Inverter from Solis 5g on Grid Three Phases Inverter for Solar Power System 30kw 33kw 36kw 40kw 50kw
Model | Solis-25K-5G | Solis-30K-5G | Solis-33K-5G | Solis-36K-5G |
Input DC | ||||
Max. DC input power(kW): | 33 | 39 | 43 | 47 |
Max. DC input voltage(V): | 1100 | 1100 | 1100 | 1100 |
Start-up voltage(V): | 180 | 180 | 180 | 180 |
MPPT voltage range(V): | 200-1000 | 200-1000 | 200-1000 | 200-1000 |
Max. input current(A): | 26+26+26 | 26+26+26 | 26+26+26 | 26+26+26+26 |
MPPT number: | 3 | 3 | 3 | 4 |
Max input strings number: | A:2; B:2; C:2 | A:2; B:2; C:2 | A:2; B:2; C:2 | A:2; B:2; C:2; D:2 |
Max. Short Circuit current for each MPPT: | 39+39+39 | 39+39+39 | 39+39+39 | 39+39+39+39 |
Output AC | ||||
Rated output power(kW): | 25 | 30 | 33 | 36 |
Max. apparent output power(kVA): | 27.5 | 33 | 36.3 | 39.6 |
Max. output power(kW): | 27.5 | 33 | 36.3 | 39.6 |
Rated grid voltage(V): | 400 | 400 | 400 | 400 |
Rated grid frequency(Hz): | 50/60 | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz): | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase: | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE |
Rated grid output current(A): | 36 | 43.3 | 47.6 | 51.9 |
Max. output current(A): | 41.8 | 50.2 | 55.1 | 60.2 |
THDi (at rated output power): | <3% | <3% | <3% | <3% |
DC injection current(mA): | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power): | 0.8leading ... 0.8lagging | |||
Efficiency | ||||
Max.efficiency: | 98.8% | 98.8% | 98.8% | 98.8% |
EU efficiency: | 98.3% | 98.3% | 98.3% | 98.3% |
MPPT efficiency: | >99.5% | >99.5% | >99.5% | >99.5% |
Protection | ||||
DC reverse-polarity protection: | Yes | Yes | Yes | Yes |
Short circuit protection: | Yes | Yes | Yes | Yes |
Output over current protection: | Yes | Yes | Yes | Yes |
Output over voltage protection: | Yes | Yes | Yes | Yes |
Insulation resistance monitoring: | Yes | Yes | Yes | Yes |
Residual current detection: | Yes | Yes | Yes | Yes |
Surge protection: | DC Type II/ AC Type II | DC Type II/ AC Type II | DC Type II/ AC Type II | DC Type II/ AC Type II |
Islanding protection: | Yes | Yes | Yes | Yes |
Temperature protection: | Yes | Yes | Yes | Yes |
Integrated DC switch: | Optional | Optional | Optional | Optional |
Strings monitoring: | Yes | Yes | Yes | Yes |
Anti-PID: | Optional | Optional | Optional | Optional |
General Data | ||||
Dimensions(mm): | 647W*629H*252D | |||
Weight(kg): | 45 | 45 | 45 | 45 |
Topology: | Transformerless | |||
Self consumption (night): | <1W(Night) | |||
Ingress protection: | Ip65 | |||
Noise emission(typical): | <30 dBA | |||
Cooling concept: | Natural convection | |||
Max.operation altitude:: | 4000m | |||
Designed lifetime: | >20years | |||
Relative humidity: | 0~100% | |||
Operating ambient temperature range: | -25~60ºC | |||
Grid connection standard: | EN50438, G99, AS4777, VDE0126-1-1, IEC61727,VDE4105(2018 | |||
Safty/EMC standard: | IEC62109-1/-2, AS3100, EN61000-6-1, EN61000-6-3 | |||
Features | ||||
DC connection: | MC4 | |||
AC connection: | Terminal coonectors | |||
Display: | LCD,2*20 Z. | |||
Communication connections: | 4 pins RS485 connector | |||
Monitoring: | WiFi or GPRS | |||
Warranty: | 5/10/15/20 Years |
Model | Solis-40K-5G | Solis-40K-HV-5G | Solis-50K-HV-5G |
Input DC | |||
Max. DC input power(kW): | 52 | 52 | 65 |
Max. DC input voltage(V) : | 1100 | 1100 | 1100 |
Start-up voltage(V) : | 180 | 180 | 180 |
MPPT voltage range(V) : | 200-1000 | 200-1000 | 200-1000 |
Max. input current(A) : | 26+26+26+26 | 26+26+26+26 | 26+26+26+26 |
MPPT number : | 4 | 4 | 4 |
Max input strings number : | A:2; B:2; C:2; D:2 | A:2; B:2; C:2; D:2 | A:2; B:2; C:2; D:2 |
Max. Short Circuit current for each MPPT : | 39+39+39+39 | 39+39+39+39 | 39+39+39+39 |
Output AC | |||
Rated output power(kW): | 40 | 40 | 50 |
Max. apparent output power(kVA) : | 44 | 44 | 55 |
Max. output power(kW) : | 44 | 44 | 55 |
Rated grid voltage(V) : | 400 | 480 | 480 |
Rated grid frequency(Hz) : | 50/60 | 50/60 | 50/60 |
Grid frequency range(Hz) : | 47-52 or 57-62 | 47-52 or 57-62 | 47-52 or 57-62 |
Operation phase : | 3/N/PE | 3/N/PE | 3/N/PE |
Rated grid output current(A) : | 57.7 | 48.1 | 60.1 |
Max. output current(A) : | 66.9 | 53 | 66.2 |
THDi (at rated output power) : | <3% | <3% | <3% |
DC injection current(mA) : | <0.5%In | <0.5%In | <0.5%In |
Power Factor (at rated output power) : | 0.8leading ... 0.8lagging | ||
Efficiency | |||
Max.efficiency: | 98.8% | 98.8% | 98.8% |
EU efficiency: | 98.3% | 98.3% | 98.3% |
MPPT efficiency : | >99.5% | >99.5% | >99.5% |
Protection | |||
DC reverse-polarity protection: | Yes | Yes | Yes |
Short circuit protection : | Yes | Yes | Yes |
Output over current protection : | Yes | Yes | Yes |
Output over voltage protection : | Yes | Yes | Yes |
Insulation resistance monitoring : | Yes | Yes | Yes |
Residual current detection : | Yes | Yes | Yes |
Surge protection : | DC Type II/ AC Type II | DC Type II/ AC Type II | DC Type II/ AC Type II |
Islanding protection : | Yes | Yes | Yes |
Temperature protection : | Yes | Yes | Yes |
Integrated DC switch : | Optional | Optional | Optional |
Anti-PID: | Optional | Optional | Optional |
General Data | |||
Dimensions(mm): | 647W*629H*252D | ||
Weight(kg) : | 45 | 45 | 45 |
Topology : | Transformerless | ||
Self consumption (night) : | <1W(Night) | ||
Ingress protection : | Ip65 | ||
Noise emission{typical} : | <30 dBA | ||
Cooling concept : | Natural convection | ||
Max.operation altitude : | 4000m | ||
Designed lifetime : | >20years | ||
Relative humidity : | 0~100% | ||
Operating ambient temperature range : | -25~60ºC | ||
Grid connection standard : | EN50438, G99, AS4777, VDE0126-1-1, IEC61727,VDE4105(2018 | ||
Safty/EMC standard: | IEC62109-1/-2, AS3100, EN61000-6-1, EN61000-6-3 | ||
Features | |||
DC connection: | MC4 | ||
AC connection : | Terminal coonectors | ||
Display : | LCD,2×20 Z. | ||
Communication connections : | 4 pins RS485 connector | ||
Monitoring : | WiFi or GPRS | ||
Warranty : | 5/10/15/20 Years |
Model | Solis-80K-5G | Solis-80K-HV-5G | Solis-90K-HV-5G | Solis-100K-HV-5G | Solis-110K-HV-5G |
Input DC | |||||
Max. DC input power(kW): | 104 | 104 | 117 | 120 | 132 |
Max. DC input voltage(V): | 1100 | 1100 | 1100 | 1100 | 1100 |
Start-up voltage(V): | 200 | 200 | 180 | 180 | 180 |
MPPT voltage range(V): | 180-1000 | 180-1000 | 200-1000 | 200-1000 | 200-1000 |
Max. input current(A): | 26 | 26 | 26 | 26 | 26 |
MPPT number: | 8 | 8 | 9 | 9 | 10 |
Max input strings number: | 16 | 16 | 2 | 2 | 2 |
Max. Short Circuit current for each MPPT: | 40.6 | 40.6 | 40.6 | 40.6 | 40.6 |
Output AC | |||||
Rated output power(kW): | 80 | 80 | 90 | 100 | 110 |
Max. apparent output power(kVA): | 88 | 88 | 99 | 110 | 121 |
Max. output power(kW): | 88 | 88 | 99 | 110 | 121 |
Rated grid voltage(V): | 400 | 480 | 480 | 480 | 480 |
Operation phase: | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE |
Max. output current(A): | 133.7 | 105.9 | 119.1 | 132.3 | 129.4 |
THDi (at rated output power): | <2% | <2% | <2% | <2% | <2% |
Power Factor (at rated output power): | 0.8leading ... 0.8lagging | ||||
Efficiency | |||||
Max.efficiency: | 99% | 99% | 99% | 99% | 99% |
EU efficiency: | 98.4% | 98.4% | 98.4% | 98.4% | 98.4% |
MPPT efficiency: | >99.5% | >99.5% | >99.5% | >99.5% | >99.5% |
Protection | |||||
Anti-islanding protection: | Yes | Yes | Yes | Yes | Yes |
DC reverse-polarity protection: | Yes | Yes | Yes | Yes | Yes |
Insulation resistance monitoring: | Yes | Yes | Yes | Yes | Yes |
Residual current detection: | Yes | Yes | Yes | Yes | Yes |
DC Surge protection: | Type replaceable | Type replaceable | Type replaceable | Type replaceable | Type replaceable |
AC Surge protection: | Type | Yes | Yes | Yes | Yes |
Grid monitoring: | Yes | Yes | Yes | Yes | Yes |
Strings Monitoring: | Yes | Yes | Yes | Yes | Yes |
I/V Curve scanning: | Yes | Yes | Yes | Yes | Yes |
Anti-PID function: | Yes | Yes | Yes | Yes | Yes |
AFCI fuction: | Optional | Optional | Optional | Optional | Optional |
General Data | |||||
Dimensins(mm): | 1050W*567H*286.5D | ||||
Weight(kg): | 75 | ||||
Topology: | Transformerless | ||||
Self consumption (night): | <2W(Night) | ||||
Ingress protection: | Ip65 | ||||
Noise emission(typical): | <55 dBA | ||||
Cooling concept: | Fan cooling | ||||
Max.operation altitude:: | 4000m(>2000m derating) | ||||
Designed lifetime: | >20years | ||||
Designed lifetime: | 0~100% | ||||
Operating ambient temperature range: | -25~60ºC | ||||
Grid connection standard: | EN50549, G99, AS4777, VDE0126-1-1, IEC61727, VDE4105 | ||||
Safty/EMC standard: | IEC62109-1/-2, NB/T 32004,EN61000-6-1, EN61000-6-3 | ||||
Features | |||||
DC switch: | Integrated | ||||
DC connection: | MC4 | ||||
AC connection: | OT Terminal connectors | ||||
DRM function: | Yes | ||||
Display: | LCD,2*20 Z. | ||||
OTA update: | Yes | ||||
Communication connections: | 1*4pin RS485,2*RJ45,1*DRM | ||||
Communication: | RS485/ WLAN(provide);PLC/Wifi/GPRS(optional) | ||||
Monitoring: | WiFi or GPRS | ||||
Warranty: | 5/10/15/20 Years |