Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer

China Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer, Find details about China Steam Sterilizer, Autoclave Steam Sterilization from Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer

Model NO.
BT-200YDB
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Metal
Power
9kw/380V 50Hz
Max. Working Pressure
0.22MPa
Max.Working Temperature
134 Degree
Adjustment of Temperature
40~134 Degree
Time for Sterilization
0~99min
Trademark
BESTRAN
Transport Package
Carton
Specification
156x91x188cm
Origin
China
Model NO.
BT-200YDB
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Metal
Power
9kw/380V 50Hz
Max. Working Pressure
0.22MPa
Max.Working Temperature
134 Degree
Adjustment of Temperature
40~134 Degree
Time for Sterilization
0~99min
Trademark
BESTRAN
Transport Package
Carton
Specification
156x91x188cm
Origin
China
BT-200YDB Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer
 
 
Technical data
BT-150YDB
BT-200YDB
BT-280YDB
Sterilizing chamber volume
150L φ440×1000mm
200Lφ 515×1000mm
280L φ600×1000mm
working pressure
0.22 MPa
working temperature
134ºC
Adjustment of temperature
40ºC - 134ºC
Time of sterilization
0-99 min
Time of drying
0-99 min
Heat average
≤± 2ºC
Power
9KW/380V 50Hz
9KW/380V 50Hz
12KW/380V 50Hz
Dimension
1400×650×1600
1400×750×1700
1520×910×1900
Transport dimension
1560×820×1820
1560×910×1880
1680×1080×2100
G.W/N.W
430/340 KG
436/350 KG
570/462 KG
Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer
Characteristics
 
1.Sterilizing course automatic sterilization controlled by computer, easy to operate.
2.With drying function, suitable dressing drying.
3.With over-temperature, over-pressure auto-protect device.
4.The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the doesn't closed well
5.The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
6.The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.
7.The chamber of the sterilizer is made of stainless steel.
8.With printer.


Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer
Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer
Bt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave SterilizerBt-200ydb Hospital Medical Autoclave Sterilization 200L Horizontal Autoclave Sterilizer