China 1 Ton 2 Ton 5 Ton 8 Ton Biomass Steam Boiler Generator Coal Furnace, Find details about China Boiler, Steam Boiler from 1 Ton 2 Ton 5 Ton 8 Ton Biomass Steam Boiler Generator Coal Furnace
Rated evaporation | t/h | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 15 | 20 | 25 | |
Rated working pressure | MPa | (1.0)1.25(1.6)(2.0) | ||||||||||||
Saturated steam temperature | ºC | (184)194(204)(215) | ||||||||||||
Feed water temperature | ºC | 20 | 104 | |||||||||||
Design thermal efficiency | % | 101~103 | ||||||||||||
Nitrogen oxides | mg/Nm | 80(BLUE)/30(FGR) | ||||||||||||
Power Supply | V/Hz | 380/50 | ||||||||||||
Exhaust gas temperature | ºC | <60 | ||||||||||||
Boiler water capacity | t | 3 | 5 | 7 | 9 | 10.8 | 10.8 | 15 | 19 | 23 | 25 | 39 | 44.5 | |
Natural gas consumption | Nm3/h | 75 | 149 | 223 | 298 | 371 | 390 | 520 | 650 | 781 | 976 | 1302 | 1621 | |
Heating area | m2 | 54.8 | 97 | 126.2 | 158.5 | 228.1 | 228.1 | 313.4 | 397.3 | 492 | 603.9 | 853 | 1014 | |
Total power consumption | kw | 4.07 | 7.37 | 12.05 | 16.1 | 21.6 | 23.6 | 27.5 | 34.5 | 38.5 | 54.2 | 76.5 | 100 | |
Combustion pattern | Chamber combustion under micro-positive pressure | |||||||||||||
Combustion regulation mode | Frequency conversion proportional regulation | |||||||||||||
Water supply mode | Frequency conversion continuous water replenishment |
burner | Model | CLVF-100/E | CLVF-200/E | CLVF-300/E | CLVF-400/E | CLVF-500/E | CLVF-600/E | CLVF-800/E | CLVF-1000/E | CLVF-1200/E | CLVF-1500/E | CLVF-2000/E | CLVF-2500/E | |
Gas supply pressure | Kpa | 7~9 | 10~13 | 10~13 | 14~16 | 14~16 | 16~18 | 16~18 | 20~22 | 20~22 | 24~26 | 25~27 | 26~30 | |
Caliber of valve group | DN | 50 | 50 | 50 | 65 | 65 | 65 | 80 | 100 | 100 | 100 | 125 | 150 | |
Load range | % | 30-110% | ||||||||||||
Interface size | DN | 65 | 65 | 65 | 80 | 80 | 80 | 100 | 125 | 125 | 125 | 150 | 200 | |
Air volume | m/h | 1340 | 2500 | 3600 | 4800 | 6000 | 7400 | 9600 | 12500 | 14800 | 17200 | 22400 | 28600 | |
Motor power | kW | 2.2 | 4 | 7.5 | 11 | 15 | 15 | 18.5 | 22 | 22 | 37 | 55 | 75 | |
Fan pressure | Pa | 2300 | 2500 | 2700 | 3200 | 3800 | 4200 | 4500 | 4800 | 5200 | 5800 | 6200 | 6600 |
Feed water N3 | DN | 25 | 32 | 32 | 40 | 40 | 50 | 50 | 65 | 65 | 65 | 80 |
80 | |||
Steam main outlet N1 | DN | 50 | 65 | 80 | 100 | 125 | 125 | 150 | 150 | 150 | 200 | 200 | 200 | |||
Steam backup outlet N2 | DN | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | ||||
Periodic blowdown N4 | DN | 40 | 40 | 40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×40 | 2×50 | 2×50 | |||
Continuous blowdown N5 | DN | / | / | / | / | / | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |||
Safety valve caliber N7 | DN | 2×50 | 2×50 | 2×50 | 2×65 | 2×100 | 2×100 | 2×100 | 2×100 | 2×100 | 2×125 | 2×125 | 2×150 | |||
Boiler flue gas outlet N8 | DN | φ250 | φ350 | φ400 | φ450 | φ500 | φ500 | φ600 | φ650 | φ700 | φ800 | φ900 | φ1000 | |||
Economizer inlet/out N9 | DN | 25 | 25 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 50 | 65 | 65 | |||
Condenser inlet/out N10 | DN | 25 | 25 | 25 | 32 | 32 | 40 | 40 | 40 | 40 | 50 | 65 | 65 | |||
Condenser drain | DN | 25 | ||||||||||||||
Flue gas duct drain N12 | DN | 32 | 32 | 32 | 32 | 32 | 32 | 40 | 40 | 40 | 40 | 50 | 50 | |||
Smoke box drain N13 | DN | 25 | 25 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | |||
Boiler Water Sampling Port | DN | 15 | ||||||||||||||
Boiler net weight | t | 5.8 | 8.7 | 10.1 | 13.6 | 17.5 | 17.5 | 21.1 | 27.2 | 30.2 | 37.3 | 49.1 | 57.1 |