Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber

China Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber, Find details about China UV Sterilizer, Ultraviolet Sterilizer from Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber

Model NO.
YLC-1000
Feature
Non-Chemical
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
Flow Rate
0.3--1000 Ton/Hour
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Trademark
YLD
Transport Package
Plywood Case Into Container
Specification
CE, SGS
Origin
Jiangyin, Jiangsu
HS Code
842121999
Model NO.
YLC-1000
Feature
Non-Chemical
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange or Thread
Flow Rate
0.3--1000 Ton/Hour
Alert System for Lamp
One Set
System Working Pressure Resistance
(0.6 MPa)6kg/Cm2
Raw Water Supplying
Running Water
Brand of Ballast
Beasun
Trademark
YLD
Transport Package
Plywood Case Into Container
Specification
CE, SGS
Origin
Jiangyin, Jiangsu
HS Code
842121999

Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber


UV disinfection has many advantages:
Immediate and safe destruction of the bacteria without addition of chemica 
Photochemical reduction of undesirable substances 
No THM or AOX formation, no formation of other undesirable substances 
No impairment of odour or taste of the water 
No storage and handling of chemicals required 
Effect is independent of pH 
No reaction vessel or reaction tank required 
Low space requirement 
Low investment and operating costs with high reliability and efficiency
Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber

 
Principle for UV sterilization
UV system is installed in-line just after your pools existing filtration system. It
bombards the passing water flow with a high intensity germicidal ultraviolet ray that
destroys more than 60 waterborne pathogens, including algae, bacteria, cysts, and viruses.
 
The UV sanitizing lamp is housed in an industrial graphite housing optimized for high flow
rates. A highly specialized quartz glass sleeve protects the lamp from passing water while
transmitting 99.9% of the UV light. The highly concentrated electromagnetic energy destroys
organic matter and eliminates the formation of dangerous chlorine by-products called  chloramines that commonly lead to red, stinging eyes, skin irritations, asthma and
allergies. This energy penetrates the cell walls of bacteria, viruses, algae, cysts and all
pathogens. That's right: no pathogen can escape a powerful dose of UV from a Spectra Light
Sterilizer.


Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber

 

Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰

Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)

DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)

As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰

Technical parameters:
modelProcessing capacity (Ton/Hour)power (W) inlet and outlet
(inch)
working pressure (Kg/cm 2 )malfunction alert for UV lampreactor dimension (cm) L×W×Hdimension of panel(cm)anchor bolt  (cm)overall weight (Kg)
YLCn-0050.3161/2"6matched30×6×11  5
YLCn-0081251/2"6matched47×6.3×11  10
YLCn-0502401"6matched100×9×20Φ8.9×25
(diameter×length)
69×4×Φ125
YLCn-1506801+1/4"6matched100×11×2369×4×Φ130
YLCn-20081201+1/2"6matched100×15.9×30Φ8.9×45
(diameter×length)
69×7×Φ135
YLCn-300121602"6matched100×15.9×3269×7×Φ140
YLC-050240DN25/1"6matched100×8.9×3025×30×12
(L×H×w)
60×4×Φ145
YLC-150680DN32/1 1/4 "6matched100×10.8×3060×4×Φ150
YLC-2008120DN40/1 1/2 "6matched100×15.9×4060×7×Φ160
YLC-30012160DN50/2"6matched100×15.9×4060×7×Φ170
YLC-36015200DN65/2 1/2"6matched100×15.9×4050×78×25
(L×H×W)
60×7×Φ1120
YLC-50020240DN65/2 1/2"6matched100×21.9×5060×11×Φ1.2130
YLC-60025280DN80/3"6matched100×21.9×5060×11×Φ1.2140
YLC-70030320DN100/4"6matched100×21.9×5060×11×Φ1.2150
YLC-100040360DN100/4"6matched100×21.9×5060×11×Φ1.2160
YLC-120050400DN125/5"6matched100×21.9×5060×11×Φ1.2180
YLC-150060420DN150/6"6matched170×27.3×57120×16×Φ1.4210
YLC-200080560DN150/6"6matched170×27.3×57120×16×Φ1.4220
YLC-2500100700DN150/6"6matched170×27.3×5760×128×30
(W×H×T)
 
120×16×Φ1.4275
YLC-3000125840DN150/6"6matched173×27.3×57120×16×Φ1.4300
YLC-40001501120DN200/8"6matched173×32.5×65120×20×Φ1.6325
YLC-50002001400DN200/8"6matched173×37.7×72120×22×Φ1.6350
YLC-70003002100DN250/10"6matched175×42.6×80120×24×Φ2.0400
YLC-10K4002520DN250/10"6matched176×52.9×9560×150×40
(W×H×T)
120×28×Φ2.2475
YLC-15K6003080DN300/12"6matched176×78×110120×32×Φ2.4600
YLC-20K8003920DN350/14"6matchedconfirmed confirmedconfirmedconfirmed
YLC-25K10004760DN350/14"6matchedconfirmedconfirmedconfirmed





Applications:
Reclaimed water recycling
Devices for secondary water supply of the living community
Disinfection of the treated municipal sewer
Disinfection of water for aquiculture and processing
Disinfection of purified water for shellfish species
Disinfection of water in aquaria and water tanks
Disinfection of tap water, purified water and mineral water
Disinfection of water for the food and beverage industries_
Disinfection of water for such water recreational facilities as swimming poor, etc. Disinfection of
drinking water for residential, office and restaurant buildings, etc. Disinfection of bacteria-free
water for pharmacy, cosmetics and other such manufacturing industries
Disinfection of water for hospitals Water for military bases, ships and vessels and submarine
vessels as well as field activities
Disinfection of water for agricultural irrigation
Disinfection of water for municipal landscapes
Disinfection of water for the water treatment system of central air conditioning in commercial buildings
Disinfection of cooling water for various large power stations
Disinfection of drinking water for commercial planes and large passenger planes Disinfection of water
for large poultry and livestock farms
Disinfection of water for small domestic drinking machine
Greenhouse seedling culture Aquaculture
Water for municipal landscapes
Disinfection of water for hospitals
Food and beverage
Manual Handle Cleaning UV Disinfector Water Sterilizer Equipment with Ss Chamber

FAQ:

How do I know what size of UV unit to buy? 
You can treat the water for your whole home or just the drinking water from one tap. If you draw on a private water supply such as tank water, it is recommended that you treat the water for your entire home. We can advise you on what size
 
Does a UV system consume a lot of energy? 
No, a UV system able to treat the water for a typical house will consume about the same amount of energy as a 60-watt light bulb. UV is a cost-effective, natural way to increase water quality. 
 
How often would I have to change the UV lamp? 
It is essential that you change the UV lamp once a year. UV lamps, light bulbs, will dim with age and eventually burn out. R-Can designs its UV units to generate the necessary UV light intensity at the end of one year's continuous use. The lamp will continue to burn long after, but it will not generate an adequate amount of UV light.