CE Certified Heighten Digital Rockwell Testing Machine (SHR-150H)

China CE Certified Heighten Digital Rockwell Testing Machine (SHR-150H), Find details about China Rockwell Testing Machine, Testing Machine from CE Certified Heighten Digital Rockwell Testing Machine (SHR-150H)

Model NO.
SHR-150H
Calibrating Method
Standard Hardness Test Blocks
Rated Voltage
220V
Support Language
English
Customized
Non-Customized
Test Force
60kgf(558.4n),100kgf(980.7n),150kgf(1471n)
Hardness Display
Digital LCD Display
Resolution
0.1hr
Force Loading
Auto Loading/Dwell/Unloading
Data Output
Mini Printer
Hardness Conversion
Hra\Hrb\Hbc\Hrd\Hrf\Hbs\Hbw\Hv\HK\Hs\Hr15n\Hr30n
Trademark
SINOWON
Transport Package
Package
Specification
CE
Origin
Guangdong, China
HS Code
9024102000
Model NO.
SHR-150H
Calibrating Method
Standard Hardness Test Blocks
Rated Voltage
220V
Support Language
English
Customized
Non-Customized
Test Force
60kgf(558.4n),100kgf(980.7n),150kgf(1471n)
Hardness Display
Digital LCD Display
Resolution
0.1hr
Force Loading
Auto Loading/Dwell/Unloading
Data Output
Mini Printer
Hardness Conversion
Hra\Hrb\Hbc\Hrd\Hrf\Hbs\Hbw\Hv\HK\Hs\Hr15n\Hr30n
Trademark
SINOWON
Transport Package
Package
Specification
CE
Origin
Guangdong, China
HS Code
9024102000
Directly to measure Rockwell hardness for metal and plastic material.
Provided with many features such as high measuring precision, wide measuring range with 15 Rockwell scales.
Automatic test force switch according the selected scale without manual operation.
Automatic load cycle. The loading, dwell, unloading process of the main test force are controlled exactly to meet standard.
Measuring results digitally displaying and can be printed, or transmitted to external computer automatically.
The tester is suitable for testing of carbon steel, alloy steel, cast iron, non ferrous metal, and engineering plastic etc.
 
The Rockwell test consists of measuring the additional depth to which a carbide ball or diamond penetrator is forced by a heavy (major) load beyond the depth of a previously applied light (minor) load (SET point).

The minor load is applied first and a SET position is established on the dial gauge or displacement sensor of the Rockwell tester. Then the major load is applied. Without moving the piece being tested, the major load is removed and, with the minor load still applied, the Rockwell hardness number is automatically indicated on the dial gauge or digital display.

The diamond penetrator is used for testing materials such as hardened steels and cemented carbides. The carbide ball penetrators, available with 1/16 inch, 1/8 inch, 1/4 inch, and 1/2 inch diameter, are used when testing materials such as steel-copper alloys, aluminum and plastics to name a few.

Rockwell testing falls into two categories: Regular Rockwell testing (e.g., C and B scales) and Rockwell superficial testing (e.g., 30 N and 30 T scales).

High Rockwell hardness numbers represent hard materials and low numbers soft materials.
When selecting a hardness tester for your application, it is important for you to consider the following:
Choose the correct test method based on the application.
Plan to use the highest test force and largest indenter possible. Consider the effects of the shape and dimensions of your test sample.

CE Certified Heighten Digital Rockwell Testing Machine (SHR-150H)

Answer these key questions:
1, What kind of hardness scale to be used?
2, What is the material to be tested, and is this material suitable to the type of test method you are considering?
3, How large is the part, component or specimen to be tested?
4, Is the test point difficult to reach?
5, What is the quantity of testing that will be done?
6, How accurate does your test result need to be?
7, What is your budget?
8, What is the required return on investment and do you have ways to measure reductions in costs- yields, throughput, operator efficiency?
9, What testing problems have you experienced in your current method?
10, How knowledgeable are the users of the tester?
CE Certified Heighten Digital Rockwell Testing Machine (SHR-150H)
 
Specifications:
Product NameDigital Rockwell Hardness Tester
ModelVexus SHR-150H
Code#811-151
Rockwell ScalesHRA,HRB,HRC,HRD,HRE,HRF,HRG,HRH,HRK,HRL,HRM,HRR
Preliminary Test Force10Kgf(98.07N)
Test Force60Kgf(558.4N),100Kgf(980.7N),150Kgf(1471N)
Dwell TimeAdjustable 1-60s
Hardness IndicationDigital LCD Display
Resolution0.1HR
Loading ControlAutomatic
Data OutputRS232/Printer
MemoryMax 500 items of test results stored automatically
Hardness ConversionHB, HV, HK,etc
Max. Height Of Specimen400mm
Instrument Throat200mm
Power supplyAC 220V/50Hz;AC110V/60Hz
Dimension(LxWxH)550 x225 x720mm
Packing Dimension630 x440 x960mm
Gross/Net Weight160Kg/130Kg
Execution StandardISO 6508 , ASTM E18 , JIS Z2245 , GB/T230
Standard Delivery:
Standard DeliveryCode#Standard DeliveryCode#
Instrument Main Body811-151Ø1.588mm Steel Ball811-421
Hardness Block (57-70) HRC811-641CCone Diamond Indenter811-401
Hardness Block (20-33) HRC811-611CØ 150mm Flat anvil811-541
Hardness Block (85-100) HRB811-641BØ 40mm V-shape Anvil811-511
Ø1.588mm Ball Indenter811-411Weight A811-711
Accessories Box811-901Weight B811-721
Anti-dust Cover811-911Weight C811-731
Qualified CertificateVexus SHR-150HInstrument ManualVexus SHR-150H
Optional Accessories:
Optional AccessoriesCode#Optional AccessoriesCode#
1/8" Steel Ball Indenter811-4311/8" Steel Ball811-441
1/4" Steel Ball Indenter811-4511/4" Steel Ball811-461
1/ 2" Steel Ball Indenter811-4711/2" Steel Ball811-481
100mm Flat Anvil811-531Small Flat Anvil811-501