China 5.0kw High Frequency with C-Arm System, Find details about China X Ray Machine, Medical Equipment from 5.0kw High Frequency with C-Arm System
Specifications |
1.Fluoroscopic Capacity Max rated capacity : Tube Current 4mA, Tube Voltage 120kV Automatic Fluoroscopy : Tube Voltage:40kV~120kV Adjust Automatically Tube Current : 0.3mA~4mA set manually Manual Fluoroscopy : Continuous Tube Voltage:40kV~120kV Continuous Tube Current : 0.3mA~4mA Pulse Fluoroscopy : Continuous Tube Voltage 40kV~120kV Continuous Tube Current 4.1mA~8mA 2. Photography Capacity Max rated capacity : 5 KW Tube Voltage and Current Combination : 40kV~49kV 1 ~180 mAs 50kV~59kV 1 ~140 mAs 60kV~69kV 1 ~125 mAs 70kV~79kV 1 ~110 mAs 80kV~89kV 1 ~100 mAs 90kV~99kV 1 ~80 mAs 100kV~109kV 1 ~63 mAs 110kV~120kV 1 ~50 mAs Plate holder Size : 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) 3.X-ray Tube X-ray Tube Special for High Frequency Fixed anode Dual-focus: large focus: 1.5, small focus: 0.3( Advantage) Inverter Frequency : 40KHz Thermal capacity : 35KJ (47KHU) 4.Video System Image Intensifier : Image Intensifier made by TOSHIBA (9″, 6″,4.5″) CCD Vidicon : Ultra low-light CCD camera imported from Japan Monitor : Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, Image/sec : 75 CCU(central control) : Recursive Filter: K=8,8 images storage, image upright, image overturn,positive & negative image;LIH(last Image Hold, and OSD(monitor display) 5.Structure: Directive wheel : ±90°revolution,can freely change the moving direction of the unit . Ascending & Descending Range of Pillar : ≥400mm C-arm : Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis : ±15° (Advantage), better than others' ±12.5°, easier to take special positions radiography ) Slip on orbit: 120°(+90°~ -30°) |
Category | Project | Content |
Electrical Performance | Photography Capacity | 5.0KW |
Fluoroscopy Capacity | Tube current:8mA Tube Voltage:120KV | |
Automatic Fluoroscopy | Tube Voltage:40kV~120kV automatical adjustment Tube Current:0.3mA~4mA automatical adjustment | |
Manual Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current:0.3mA~4mA Continuous | |
Pulse Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current:4.1mA~8mA Continuous | |
Photography Tube Voltage and mAs | 40 kV~120 kV 20-100mA 1-180mAs | |
film holder Size | 200mm×250mm(8″×10″)or 250mm×300mm(10″×12″) | |
X-ray Tube | X-ray Tube Special for High Frequency | Fixed anode Dual-focus, small focus: 0.3, large focus:1.5 High Frequency Inverter: 40KHz thermal capacity 35KJ (47KHU) Tube thermal capacity 650KJ(867KHU) |
Video System | Image Intensifier | TOSHIBA (9″) Image Intensifier |
CCD Video camera | Ultra low-light CCD camera | |
Monitor | Horizontal center resolution 1000/L, frequency for picture refresh is 75HZ | |
CCU main control | High Definition progressive output mode, 8 level Noise Reduction,8 image storage, Vertical Image, Horizontal image flip, positive or negative image | |
Structure | Directive wheel and major wheel | Directive wheel 360° rotation, freely change the moving direction of the unit, major wheel ±90° rotation |
C-arm | Electrical Ascending & Descend ≥400mm Monitor rotation 135° Forward and Backward Movement: 200mm Rotation around Horizontal Axis: ±180° Rotation around Vertical Axis : ±15° Focus screen distance:960mm C-arm opening: 760mm C-arm arc depth: 640mm Slip on orbit: 120°(+90°~ -30°) |