Ah3 -N Time Relay Electric Time Relay

China Ah3-N Time Relay Electric Time Relay, Find details about China Time Relay, Solid State Relay from Ah3-N Time Relay Electric Time Relay

Model NO.
AH3-N
Size
Miniature
Type
Electric Parameter Relay
Dimensions
50h×40W×57.5D
Rated Voltage
DC(V): 12, 24 AC(V): 12, 24, 110, 220, 240, 380 50
Life
5×106times
Consumed Power
2va
Ambient Temperature
-10oc~+55oc
Ambent Huminity
45~85%Rh
Trademark
Langir
Transport Package
1PCS Per Box
Specification
CE
Origin
Wenzhou, China
Model NO.
AH3-N
Size
Miniature
Type
Electric Parameter Relay
Dimensions
50h×40W×57.5D
Rated Voltage
DC(V): 12, 24 AC(V): 12, 24, 110, 220, 240, 380 50
Life
5×106times
Consumed Power
2va
Ambient Temperature
-10oc~+55oc
Ambent Huminity
45~85%Rh
Trademark
Langir
Transport Package
1PCS Per Box
Specification
CE
Origin
Wenzhou, China
http://langir.en.made-in-china.com

Features
Used to control time sequence
With front / back connecting socket
LED display
Technical Data

Classification
Multi Range Timer
ModelAH3-N
Dimensions50H×40W×57.5D
Mounting & SockerSurface(-N)PF083A(E)
Flush(-Y)US-08, P3G-08
Full Timing RangeA: 1s, 10s, 1m, 10m
B: 3s, 30s, 3m, 30m
C: 6s, 60s, 6m, 60m
D: 1m, 10m, 1h, 10h
E: 3m, 30m, 3h, 30h
Rated VoltageDC(V): 12, 24
AC(V): 12, 24, 110, 220, 240, 380 50/60Hz
Indicator OperatingTime Operating Flicker
O/P ContactModelA/ B
Time Limit 1C 5A
Time Limit 2C5A 
Instantenous 1C 5A
LifeMechanical5×106times
Electrical105times
AccuracyRepea Error±1% Max.
Setting Error±10% Max.
Voltage Error±1% Max.
Temp. Error±2% Max.
Reset Time0.1 Sec. Max.
Consumed Power2VA
Ambient Temperature-10ºC~+55ºC
Ambent Huminity45~85%RH
Weight160g
Connection Diagrams & Timing Chart33H33J